Brick Fuses 6125TD Series, Time Delay Description RoHS 2002/95/EC Time Delay surface mount fuse Complies with EIA-IS-722 Standard Solder Immersion Compatible ELECTRICAL CHARACTERISTICS % of Amp Rating Opening Time 100% 4 Hours Minimum 200% 1 Second Minimum 200% 2-4 Seconds Typical 200% 60 Seconds Maximum mm Dimensions (inches) Agency Information UL Recognition Guide & File numbers: JDYX2 & E19180. CSA Component Acceptance: 053787 C 000 & Class No: 1422 30. Environmental Data Life Test: MIL-STD-202, Method 108A, Test Condition D Load Humidity: MIL-STD-202, Method 103B Moisture Resistance: MIL-STD-202, Method 106E Thermal Shock: MIL-STD-202, Method 107D, air-to-air Case Resistance: EIA/IS-722 2.6 3.0 Resistance to Dissolution of Metallization: Land Pattern (0.102) (0.118) ANSI J-STD-002, Test D Mechanical Shock: MIL-STD-202, Method 213B, Test 4.0 Condition A (0.157) High Frequency Vibration: MIL-STD-202, Method 204D, Test Condition D 8.6 Resistance to Solvents: MIL-STD-202, Method 215A (0.338) Ordering Soldering Method Specify packaging and product code Wave Immersion: 260C, 10 sec max. (i.e., TR1/6125TD500-R) Infrared: 260C, 30 sec max. SPECIFICATIONS Product Current Voltage Interrupting Resistance Typical Typical Code Rating Rating Rating* (ohms)** Melting Voltage 2 AC DC 125VAC 60VDC Typ. I t Drop 6125TD500-R 500mA 125V 60V 50A 50A 0.4025 0.716 245 mV 6125TD750-R 750mA 125V 60V 50A 50A 0.2350 1.07 250 mV 6125TD1-R 1A 125V 60V 50A 50A 0.1680 2.88 256 mV 6125TD1.5-R 1.5A 125V 60V 50A 50A 0.0630 2.35 125 mV 6125TD2-R 2A 125V 60V 50A 50A 0.0480 9.45 133 mV 6125TD2.5-R 2.5A 125V 60V 50A 50A 0.0350 16.2 130 mV 6125TD3-R 3A 125V 60V 50A 50A 0.0263 15.3 97 mV 6125TD3.5-R 3.5A 125V 60V 50A 50A 0.0195 14.5 95 mV 6125TD4-R 4A 125V 60V 50A 50A 0.0185 38.8 106 mV 6125TD5-R 5A 125V 60V 50A 50A 0.0133 34.4 100 mV 6125TD7-R 7A 125V 60V 50A 50A 0.0087 90.2 99 mV * AC Interrupting Rating (Measured at designated voltage, 100% power factor) DC Interrupting Rating (Measured at designated voltage, time constant of less than 50 microseconds, battery source) ** DC Cold Resistance (Measured at 10% of rated current) 2 Typical Melting I t (Measured with a battery bank at rated DC voltage, 10x-rated current (not to exceed IR), time constant of calibrated circuit less than 50 microseconds) Typical Voltage Drop (Measured at rated current after temperature stabilizes) Device designed to carry rated current for four hours minimum. An operating current of 80% or less of rated current is recommended, with further derating required at elevated ambient temperatures. Brick Fuses 6125TD Series, Time Delay TIME CURRENT CURVE PACKAGING CODE Packaging Code Description TR1 1000 pieces of fuses on 12mm tape-and-reel on a 7 inch (177mm) reel per EIA Standard 481 Visit us on the web at: North America Europe Asia Pacific www.cooperbussmann.com Cooper Electronic Technologies Cooper Bussmann Cooper Electronic Technologies Cooper Electronic Technologies Cooper Electronic Technologies 1225 Broken Sound Parkway NW P.O. Box 14460 Cooper (UK) Limited Avda. Santa Eulalia, 290 1 Jalan Kilang Timor OC-2530 Rev. M 3/07 Suite F St. Louis, MO 63178-4460 Burton-on-the-Wolds 08223 06-01 Pacific Tech Centre Boca Raton, FL 33487-3533 Tel: 1-636-394-2877 Leicestershire LE12 5TH UK Terrassa, (Barcelona), Spain Singapore 159303 Cooper Electronic Tel: 1-561-998-4100 Fax: 1-800-544-2570 Tel: +44 (0) 1509 882 737 Tel: +34 937 362 812 Tel: +65 278 6151 Technologies 2007 Fax: 1-561-241-6640 Fax: +44 (0) 1509 882 786 +34 937 362 813 Fax: +65 270 4160 Toll Free: 1-888-414-2645 Fax: +34 937 362 719