Universal Series timers TR timing relays Reducing your inventory costs Reducing your labor costs Eatons Universal TR Series timers are a versatile and cost-competitive family of timing relays. The compact With up to seven selectable During initial installation, the timing functions and seven large terminals on the Universal IEC-style housing installs easily onto a standard DIN rail, selectable time ranges from TR Series make wiring quick and the direct-wire design eliminates the need for 50 milliseconds to 100 hours, and easy. The offset design you can meet the needs of even allows easy access to the additional sockets and accessories. Each timer has multiple almost any application with bottom terminals when the top user-selectable timing functions and timing ranges, and a just one or two stock items. wires are installed. The easy-to- universal input voltage of either 12 or 24 volts to 240 volts Do you need 24 Vdc control in read set point markings improve some cases and 120 Vac control the accuracy of setup, thereby AC or DC, depending on the model. in others You are covered with reducing your startup time. Are the Universal TR Series timer, as you spending too much time it has a universal, self-selecting troubleshooting and replacing control voltage input range from timers The dual LED indicators either 12 or 24 volts (depending on the Universal TR Series use on model) to 240 volts AC or multiple modes to signal input DC. Are you tired of buying power, relay state and timing minimum quantities of sockets status. The Universal TR Series and accessories for your plug-in also features a high-quality timing relays The direct wire design with twice the relay life design of the Universal TR of many competitors. Series gives you everything youneed in a single item.Speci cations Universal TR Timing Relays Specification TRL04 TRL07 TRL27 TRW27 Functions 8, 9, 10, 14 8, 9, 10, 11, 12, 13, 14 8, 9, 10, 11, 12, 13, 14 1, 2, 3, 4, 5, 6, 7 Time range 0.05 sec to 100 hours 0.05 sec to 100 hours 0.05 sec to 100 hours 0.05 sec to 100 hours Input Supply voltage 24 to 240 Vac/dc 24 to 240 Vac/dc 12 to 240 Vac/dc 12 to 240 Vac/dc Duty cycle 100% 100% 100% 100% Output Contact conguration SPDT (one changeover contact) SPDT (one changeover contact) DPDT (two changeover contacts) DPDT (two changeover contacts) Rated voltage 250 Vac 250 Vac 250 Vac 250 Vac Switching capacity 2000 VA (8A/250V) 2000 VA (8A/250V) 2000 VA (8A/250V) 2000 VA (8A/250V) Mechanical life 20 x 10 6 operations 20 x 10 6 operations 20 x 10 6 operations 20 x 10 6 operations Electrical life 2 x 10 5 operations at 1000 VA 2 x 10 5 operations at 1000 VA 2 x 10 5 operations at 1000 VA 2 x 10 5 operations at 1000 VA load, resistive load, resistive load, resistive load, resistive Accuracy Base accuracy 1% of maximum scale value 1% of maximum scale value 1% of maximum scale value 1% of maximum scale value Adjustment accuracy <5% of maximum scale value <5% of maximum scale value <5% of maximum scale value <5% of maximum scale value Repetition accuracy <0.5% or 5 ms <0.5% or 5 ms <0.5% or 5 ms <0.5% or 5 ms Physical Ambient temperature 25 to +55C 25 to +55C 25 to +55C 25 to +55C Timer Function Descriptions Function 1 Function 8 Input Power (U) Input Power (U) Asymmetrical ON Delay, Power LED U/t* LED U/t* Flasher, Triggered (E) Output LED** Output LED** Pause First (lp) Output Relay (R) t1 t2 t1 t2 t1 Output Relay (R)t<t Function 2 Input Power (U) Function 9 Input Power (U) Asymmetrical Single Shot Leading LED U/t* LED U/t* Flasher, Edge Voltage Output LED** Output LED** Pulse First (li) Controlled (Wu) Output Relay (R) t1 t2 t1 t2 t1 Output Relay (R)t<t Function 3 Input Power (U) Function 10 Input Power (U) ON Delay and OFF Delay/Signal LED U/t* LED U/t* OFF Delay with OFF Delay (R) Trigger Signal (S) Trigger Signal (S) Control Contact (ER) Output LED** Output LED** Output Relay (R) t1 t2 <t1 Output Relay (R) t <t Function 4 Input Power (U) Function 11 Input Power (U) ON Delay and Single LED U/t* Single Shot LED U/t* Shot Leading Edge Output LED** Leading Edge with Trigger Signal (S) Voltage Controlled Output Relay (R) t1 t2 Control Input (Ws) Output LED** (EWu) Output Relay (R) t t Function 5 Input Power (U) ON Delay and Single LED U/t* Function 12 Input Power (U) Shot Leading Edge Trigger Signal (S) Single Shot Trailing LED U/t* Control Contact Output LED** Edge with Control Trigger Signal (S) (EWs) Output Relay (R) t1 t2 Input (Wa) Output LED** Output Relay (R) tt Function 6 Input Power (U) Single Shot Leading LED U/t* Function 13 Input Power (U) and Single Shot Trigger Signal (S) ON Delay Control LED U/t* Trailing Edge with Output LED** Signal Start, Trigger Signal (S) Control Contact Output Relay (R) t1 t2 t1 t2 Trailing Edge OFF (WsWa) Output LED** (Es) Output Relay (R) t<t Function 7 Input Power (U) Pulse Sequence LED U/t* Function 14 Input Power (U) Monitoring (Wt) Trigger Signal (S) Flasher, LED U/t* Output LED** Pause First (Bp) Output LED** Output Relay (R) t1 <t2 <t2 <t2 t2 Output Relay (R) ttttt <t Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com PowerChain Management is a registered 2009 Eaton Corporation trademark of Eaton Corporation. All Rights Reserved Printed in USA All other trademarks are property of their Publication No. PA04910001E / Z8907 respective owners. August 2009