Effective December 2015 Technical Data 4409 Supersedes April 2011 UP5 High power, drum inductors Applications Buck or boost inductor Desktop computer Workstations/servers DVD Players Portable power devices Base stations Industrial power supplies Output filter chokes Test equipment instrumentation Environmental Data Storage temperature range: -40C to +125C Description Operating temperature range: -40C to +125C 18.54 x 15.24 x 7.11mm maximum surface (ambient plus self-temperature rise) mount package Solder reflow temperature: J-STD-020D Ferrite core material compliant Inductance range from 1.0H to 1000H HALOGEN Current range from 0.56 to 20 Amps HF Pb FREE Frequency range up to 1MHz RoHS compliantUP5 Technical Data 4409 Effective December 2015 High power, drum inductors Product Specifications 3 sat (amps) DCR m 20C 5 1 2 4 Part Number OCL H 20% Irms (amps) 25C SRF MHz typical Maximum K-factor UP5-1R0-R 1.0 8.6 20.0 140 9.0 73.61 UP5-1R5-R 1.5 7.5 18.0 110 12.0 60.22 UP5-2R2-R 2.2 7.1 16.0 75.0 14.0 50.96 UP5-3R3-R 3.3 6.2 14.0 70.0 18.0 44.16 UP5-5R6-R 5.6 5.3 12.0 45.0 20.0 31.55 UP5-100-R 10.0 4.3 10.0 21.0 31.0 24.54 UP5-150-R 15.0 4.0 8.0 16.0 36.0 20.07 UP5-220-R 22.0 3.5 7.0 13.0 47.0 16.99 UP5-330-R 33.0 3.0 5.5 11.0 66.0 14.09 UP5-470-R 47.0 2.6 4.5 9.0 86.0 11.62 UP5-680-R 68.0 2.3 3.5 6.5 130 9.60 UP5-101-R 100 1.8 3.0 5.7 190 7.98 UP5-151-R 150 1.5 2.6 4.5 250 6.56 UP5-221-R 220 1.2 2.4 3.7 380 5.39 UP5-331-R 330 1.0 1.9 3.0 560 4.39 UP5-471-R 470 0.82 1.4 2.7 850 3.70 UP5-681-R 680 0.72 1.2 2.2 1100 3.08 UP5-102-R 1000 0.56 1.0 2.0 1800 2.54 1. OpenCircuitInductance(OCL)TestParameters:100kHz,0.25Vrms,0.0Adc 4. K-factor:UsedtodetermineBp-pforcoreloss(seegraph).Bp-p=K*L*I,Bp-p:(Gauss), K: (K-factor from table), 2. Irms: DC current for an approximate T rise of 40C without core loss. Derating is necessary for AC currents. PCB L: (inductance in H), I (peak-to-peak ripple current in amps). layout, trace thickness and width, air-flow and proximity of other heat generat- ing components will affect the 5. Part Number Definition: UP5-xxx-R temperature rise. It is recommended the part temperature not exceed 125C under worst case operating conditions UP5 = Product code and size verified in the end application. xxx= Inductance value in H, R = decimal point. If no R is present, then third digit equals the number of zeros. 3. Isat: Peak current for approximately 10% rolloff at 25C. -R suffix = RoHS compliant Dimensions (mm) xxx = Inductance value in H (R = Decimal point). If no R is present, then the third digit equals the number of zeros. wwllyy = Date code R = Revision level www.eaton.com/elx 2