Shaftextension,L=25mm Partno. ZAV-P3 Articleno. 029417 Deliveryprogramme Product range Accessories Part group reference T5 T5B P3 Basic function shaft extensions Plastic Shaft length mm 25 For use with T5(B)-/Z P3-/Z P3-/V Notes A max. of 4 units can be put on the switch shaft every 25 mm Approvals North America Certification UL/CSA certification not required DatafordesignverificationaccordingtoIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I A 0 n Heat dissipation per pole, current-dependent P W 0 vid Equipment heat dissipation, current-dependent P W 0 vid Static heat dissipation, non-current-dependent P W 0 vs Heat dissipation capacity P W 0 diss IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard s requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard s requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard s requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat Meets the product standard s requirements. and fire due to internal electric effects 10.2.4 Resistance to ultra-violet (UV) radiation Please enquire 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard s requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard s requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder s responsibility. 10.8 Connections for external conductors Is the panel builder s responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder s responsibility. 10.9.3 Impulse withstand voltage Is the panel builder s responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder s responsibility. 10.10 Temperature rise Not applicable. 10.11 Short-circuit rating Is the panel builder s responsibility. The specifications for the switchgear must be observed. 12/19/2014 029417 - HPL-ED2014 V9.0 EN 1 / 210.12 Electromagnetic compatibility Is the panel builder s responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. TechnicaldataETIM5.0 Low-voltage industrial components (EG000017) / Axle for switch (EC000916) Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Switch axle (ecl ss8-27-37-04-13 AKF011009 ) Length mm 25 Cross section height mm 15 Cross section width mm 15 Additionalproductinformation(links) Technical overview cam switch, switch-disconnector