Speed signal /2 Speed-proportional rectangular pulse for external speed monitoring of fan motor. 2, 3 or 6 pulses per revolution. Open collector signal output. Extremely wide operating voltage range. Easy adaptation to user interface. Connection via separate lead. The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or several interconnected fans. Electrical connection Fan Customer (+)Power UB UB +UBS Signal data output Isink US Type VDC mA VDC mA VDC mA Page (-)Power 250 0,4 2 30 0 30 2 2 23 400 F 0,4 1 30 0 30 2 2 24 All voltages measured to ground. 400 0,4 1 30 0 30 2 2 25 External load resistor R / U / U required. a S BS 400 J 0,4 2 30 0 30 4 2 26 500 F 0,4 1 30 0 30 2 2 27 Signal output voltage Standard signalforallmodels (exceptions seebelow) 600 F 0,4 1 30 0 30 2 2 28 620 0,4 2 30 0 30 4 2 29 USHigh U s 630 U 0,4 2 30 0 30 4 2 30 s U SLow t 600 N 0,4 2 28 0 28 4 2 31 t t 1 2 600 J 0,4 2 30 0 30 4 2 33 1Rotation 700 F 0,4 2 30 0 30 4 2 34 2Pulse/Rotation 8450 0,4 2 28 0 28 4 2 35 Signal frequenzy F =2xn/60Hz 8400 N 0,4 2 28 0 28 4 2 36 8400 N VARIOFAN 0,4 2 30 0 30 4 2 37 onlyfor 4100NH7andNH8 8300 0,4 2 30 0 30 4 2 38 USHigh U s 8200 J 0,4 2 30 0 30 4 2 39 USLow 3400 N 0,4 2 28 0 28 4 2 40 t 3400 N VARIOFAN 0,4 2 30 0 30 4 2 41 t1 t2 3300 0,4 2 30 0 30 4 2 42 1Rotation 3212 J / 3214 J 0,4 2 30 0 30 4 2 43 3Pulse/Rotation Signal frequenzy F =3xn/60Hz 3218 J 0,4 2 60 0 60 4 2 43 4412 F / 4414 F 0,4 2 30 0 30 4 2 44 All TD fans. Ex.: 6400 TD 6200NTD, 6400TD,DV6200 TD,DV6400TD,RER /RG160NTD 4418 F 0,4 2 60 0 60 4 2 44 4400 FN 0,4 2 30 0 30 4 2 45 USHigh U s 4312 / 4314 0,4 2 30 0 30 4 2 46 USLow t 4318 0,4 2 60 0 60 4 2 46 t1 t2 4312 / 4314 VARIOFAN 0,4 2 30 0 30 4 2 47 1Rotation 4318 VARIOFAN 0,4 2 60 0 60 4 2 47 6Pulse/Rotation 4400 0,4 2 30 0 30 4 2 48 Signal frequenzy F =6xn/60Hz 4100 N 0,4 2 30 0 30 4 2 49 4100 NHH...NH6 0,4 2 60 0 60 10 2 50 Fan Speed nmax 4100 NH7...NH8 0,4 2 60 0 60 20 3 51 n DV 4100 0,4 2 30 0 30 4 2 52 n min t 5200 N 0,4 2 30 0 30 4 2 53 110 Speed signal U S Low Condition: I sink Speed signal U S High Condition: I source Sensor operating voltage U BS Perm. sink current I sink max. Pulses per revolution Fan descriptionAvailable on request: Electrically isolated sensor and signal circuit. Varying voltage potentials for power and logic circuit. Signal data Type VDC mA VDC mA VDC mA Page DV 5200 0,4 2 30 0 30 4 2 54 5112 N 0,4 2 15 0 5 20 2 55 5114 N / 5118 N 0,4 2 60 0 60 20 2 55 5300 0,4 2 72 0 72 4 2 56 5300 TD 0,4 2 72 0 72 20 6 57 7112 N / 7118 N 0,4 2 60 0 60 20 2 58 7114 N 0,4 2 30 0 30 20 2 58 7200 N 0,4 2 15 0 15 20 2 59 6300 0,4 2 72 0 72 20 2 61 6300 TD 0,4 2 72 0 72 20 6 62 DV 6200 0,4 2 30 0 60 20 2 64 6400 0,4 2 60 0 60 20 2 66 2200 FTD 0,4 2 72 0 72 20 6 70 RL 48 0,4 2 3 0 30 4 2 81 RL 65 0,4 2 30 0 30 4 2 82 RL 90 N 0,4 2 30 0 30 4 2 83 RLF 100 0,4 2 30 0 30 4 2 84 RG 90 N 0,4 2 30 0 30 4 2 85 RG 125 N 0,4 2 30 0 30 4 2 86 RG 160 N 0,4 2 30 0 30 20 2 87 RG 160 TD 0,4 2 60 0 60 20 6 88 RG 190 TD 0,4 2 72 0 72 20 6 89 RG 220 TD 0,4 2 72 0 72 20 6 90 RG 225 TD 0,4 2 72 0 72 20 6 91 RET 97 TD 0,4 2 72 0 72 20 6 92 REF 100 0,4 2 30 0 30 4 2 93 RER 120 TD 0,4 2 72 0 72 20 6 95 RER 133 TD 0,4 2 72 0 72 20 6 97 RER 160 TD 0,4 2 60 0 60 20 6 99 REF 175 TD 0,4 2 72 0 72 20 6 100 RER 175 TD 0,4 2 72 0 72 20 6 101 RER 190 TD 0,4 2 72 0 72 20 6 102 Attention: With these fan options, deviations in regard to temperature range, voltage RER 220 TD 0,4 2 72 0 72 20 6 103 range and power consumption are possible compared with standard fan RER 225 TD 0,4 2 72 0 72 20 6 104 data. 111 Speed signal U S Low Condition: I sink Speed signal U S High Condition: I source Sensor operating voltage U BS Perm. sink current I sink max. Pulses per revolution Fan description Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials DC centrifugal fans DC axial fans Information