Product Information

4114NXU

4114NXU electronic component of ebm papst

Datasheet
DC Fans DC Tubeaxial Fan, 119x119x38mm, 24VDC, 168m3/h, 5.6W, 3200RPM, IP68 Rated

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 84.7205 ea
Line Total: USD 84.72

29 - Global Stock
Ships to you between
Mon. 27 May to Wed. 29 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
93 - WHS 1


Ships to you between Mon. 27 May to Wed. 29 May

MOQ : 1
Multiples : 1

Stock Image

4114NXU
ebm papst

1 : USD 90.8155
10 : USD 88.55
25 : USD 86.986
36 : USD 76.0035
108 : USD 69.897
252 : USD 69.897
504 : USD 69.8855
1008 : USD 69.8165
2520 : USD 69.7705

     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Product
Type
Height
Width
Supply Voltage
Operating Supply Voltage
Airflow
Speed
Bearing Type
Noise
IP Rating
Power Rating
Frame Dimensions - mm
Housing Material
Termination Style
Series
Length
Brand
Current Type
Size
Cnhts
Hts Code
Product Type
Factory Pack Quantity :
Subcategory
Taric
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
FAD1-04020CBLW11 electronic component of Qualtek FAD1-04020CBLW11

DC Fan Axial Ball Bearing 12V 6.999CFM 30dB 40 X 40 X 20mm
Stock : 101

OD1238-24MB electronic component of Orion OD1238-24MB

DC Fans DC Fan, 120x38mm, 24VDC, 95CFM, 0.23A, 41dBA, 2540RPM, Dual Ball Bearing, Wire Leads
Stock : 44

OD9225-12HB electronic component of Orion OD9225-12HB

DC Fans DC Fan, 92x25mm, 12VDC, 53CFM, 0.24A, 35dBA, 2900RPM, Dual Ball Bearing, Wire Leads
Stock : 404

276DM-1LP11-000 electronic component of Etri 276DM-1LP11-000

DC Fan Ball Bearing 12V 0.07A 0.84W 5500RPM 4.6CFM 28dB Flange Mount
Stock : 1

SD8025-24M-S electronic component of Sinwan SD8025-24M-S

24DC 80*80*25 SLV/BRNG 32CFM TUBE AXIAL SLEEVE BEARING
Stock : 1

FAD1-04010BBLW11 electronic component of Qualtek FAD1-04010BBLW11

DC Fan Axial Ball Bearing 5V 4.2CFM 21dB 40 X 40 X 10.5mm
Stock : 131

CFM-A225-13-10 electronic component of CUI Devices CFM-A225-13-10

DC Fan Axial Ball Bearing 12V 6V to 13.8V 126.89CFM 53.5dB 120 X 120 X 25.4mm High Speed
Stock : 1

AUB0824VH electronic component of Delta AUB0824VH

DC Fans DC Tubeaxial Fan, 80x25.4mm, 24VDC, Superflo Bearing, Lead Wires
Stock : 95

109P0412G3023 electronic component of Sanyo Denki 109P0412G3023

DC Fans DC Fan, 40x28mm, 12VDC, Groove for Lead
Stock : 1

3110KL-04W-B40-E00 electronic component of MinebeaMitsumi 3110KL-04W-B40-E00

DC Fan Axial Ball Bearing 12V 6V to 13.8V 35.3CFM 31dB 80 X 80 X 25mm
Stock : 0

Operating manual 1 SAFETY REGULATIONS AND INFORMATION 4114 NXU Read the operating manual carefully before commencing work at the product. Pay attention to the following warnings to avoid risk to persons or malfunctioning. This operating manual is an integral part of the product. In the event of resale or change of ownership the operating manual must accompany the product. This operating manual may be copied and provided as information on potential risks and their avoidance. Hazard classification of warning notices The following risk ratings are used in this operating manual to denote potential risk situations and important safety instructions: DANGER This is a potentially dangerous situation Product type, manufacturing date (calendar week/year of construction) and warns of an impending health risk and if required, conformity mark can be found on the nameplate on the or risk of fatal injury if this warning is product. not observed. Observe this warning. Please provide us with the contents of the nameplate when making WARNING enquiries about the product. The dangerous situation can occur and can result in major or fatal injuries if the ebm-papst St.Georgen GmbH & Co. KG warning is not observed. Work with Hermann-Papst-Strae 1 extreme care. D - 78112 St.Georgen CAUTION The dangerous situation can occur and Phone: +49 (0) 7724 / 81-0 can result in minor injuries or damage Fax: +49 (0) 7724 / 81-1309 to property if the warning is not observed. info2 de.ebmpapst.com NOTE www.ebmpapst.com A potentially dangerous situation can occur and results in damage to As per: 04.02.2013 property if not avoided. Version 1 4 Article number: 9294310177 Qualification of personnel Only skilled electricians are permitted to install the product, to carry out Original operating manual the test run and to work at the electrical unit. Only instructed and authorized skilled personnel are permitted to INDEX transport, unpack, operate and service the product. Basic safety regulations 1 SAFETY REGULATIONS AND INFORMATION 1 Safety risks related to the product must be reassessed after installing in the final device. 2 INTENDED USE 2 The operating manual was developed in accordance with European market requirements and may need adapting to the market requirements of the country in question. 3 TECHNICAL DATA 3 When working at the product, observe the following: 4 CONNECTION AND COMMISSIONING 3 Do not make any changes to the product. WARNING 5 FAULTS, POSSIBLE CAUSES AND REMEDIES 4 Impermissible high load Stop the product immediately after 6 APPROVALS 4 impermissible loading (e.g. impact, heat, overvoltage). page 1 of 5 Electrical voltage and current Store the product in a dry and clean environment that is well protected. DANGER Ensure that the storage temperature is adhered to,see Chapter 3, Electrical voltage Technical Data.If the product is not operated for a longer period of time, we recommend running it for approx. 15 minutes annually to Regularly check the electrical move the motor bearings. equipment of the product. Eliminate immediately loose Cleaning connections and defective cables. Safety and protective functions NOTE Product damaged during cleaning DANGER Missing safety device and faulty Do not clean the product using a protective equipment. water jet or pressure washer. Do not put any pressure on the rotor. Without protective equipment severe Do not use cleaning agents injuries can occur, e.g. by taking hold of containing acids, caustic solutions the rotating equipment. or solvents. Operate the product with protection guards only. Electromagnetic radiation Disposal Electromagnetic compatibility (EMC) may affect the system integration When disposing of the product, observe all requirements and of the product due to interaction. regulations that are relevant in your country. Ensure the electromagnetic compatibility of the entire system. 2 INTENDED USE Moving parts The product is designed exclusively as a built-in device for conveying DANGER air according to the technical data. Self-starting product Every use that is not in accordance with the intended purpose, is regarded as misuse of the product. If voltage is applied, the motor On-site installations must comply with the mechanical, thermal and automatically restarts after a mains service life requirements, see Chapter 3, Technical Data. failure or when blocking has been eliminated. Intended use includes: Do not stand in the danger zone of the product. - Operating the product with all protective equipment Switch off the mains voltage when - Do not put the product into operation before it has been installed in working on the product and secure the customer s application against switching on again. - Observation of the operating manual WARNING Rotating fan Use for other than the intended purpose Using the product for the purposes mentioned below is prohibited and Long hair, loose-fitting garments and can be dangerous: jewellery can be caught and pulled into the product. Risk of injury. - Conveyance of air that contains abrasive particles. Do not wear loose-fitting garments - Conveyance of air that has a highly corrosive effect. or jewellery when working on - Conveyance of air that has a high dust load, e.g. vacuuming moving parts. sawdust. Protect long hair by wearing a hair - Conveyance of inflammable gases/particles. net. - Contact with materials that can damage the product, e.g. acids, caustic solutions, solvents. CAUTION - Exposure to radiation that can damage product components, e.g. High risk of fire spreading strong UV rays or thermal radiation. - Operating during external vibration. Can cause fire to spread. Never direct the airflow - Operating the product close to inflammable materials or components. (intake/exhaust side) at a potential - Operating the product in an explosive atmosphere source of fire. - Use of the prouct as a safety component or for performing safety- relevant functions. Hot surface - Operating in medical devices with life-sustaining or life-saving function. CAUTION - Operating in non-stationary systems, e.g. railway vehicles, aircraft High temperature at motor housing. and spacecraft. Risk of burns - Operating with fully or partially dismantled or manipulated protective equipment. Provide adequate protection against - Operating the product under conditions other than those mentioned accidental contact. in the technical data. - Furthermore, all fields of application not mentioned under intended Transport use. Only transport the product in its original packaging. Secure during An in situ assessment must be conducted of the heating behavior transport. (appropriate and inappropriate operation), the protection against The vibration values, temperature and climate ranges should not be contact, electrical shocks, impact of foreign objects or water and the exceeded during transport. usage at altitudes higher than 2000 meters. Storage Contact ebm-papst if you have specific queries regarding the product. page 2 of 5

Tariff Desc

8414.59.90 FANS INCORPORATING BRUSHLESS MOTORS, having ANY of the following:
(a) DC powered;
Op. 19.10.2000 Dec. 05.01.2001 - TC 0008777
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted