119 x 38 mm (4.7 X 1.5 ) Brushless DC 4100 Series Airflow cubic meters/hour 40 80 120 160 200 125 .50 .40 100 75 .30 .20 50 .10 25 DIMENSIONS 1 2 0 20 40 60 80 100 120 Airflow CFM (cubic feet /minute) HIGH PERFORMANCE SINTEC SLEEVE BEARING SYSTEM 4.69 X 4.96 X 1.50 Brushless DC, Metal housing, Plastic Impeller, Air Intake Over Struts PART Type of DC Voltage CFM Temp. Wgt. Approvals* Curve NUMBER Bearing Volts Range Watts 0 dBA Max C (oz) Features UL CSA VDE 1 4182NGX Sleeve 12 7 - 15 3.5 94 44 75 14 .110 x .02 Terminals 2 4182NX Ball 12 7 - 15 4.5 106 49 75 14 .110 x .02 Terminals 1 4184NGX Sleeve 24 12 - 30 3.5 94 44 75 14 .110 x .02 Terminals 2 4184NX Ball 24 12 - 29 4.5 106 49 75 14 .110 x .02 Terminals 1 4188NXM Ball 48 36 - 56 3.5 94 44 75 14 .110 x .02 Terminals 1 4105GX Sleeve 5 4.5 - 5.5 4.0 94 44 72 17 .110 x .02 Terminals * UL yellow card E38324, CSA file 27697, VDE file 8324 Mounting: From either face using four Connection: Terminals two flat pins: CONSTRUCTION MOUNTING & .146 (3.7 mm) holes .110 x .02 (2.8 x .5 mm) CONNECTION Weight: 14 ounces (390g) except 4105GX Options: Hall Effect monitor Housing: Metal with plastic impeller Call ebm/Papst at 860-674-1515 Fax 860-674-8536 E-mail: sales ebm.com for Technical Assistance 38 ebm/Papst 1995, 1996, 1997. ebm/Papst reserves the right to change any specifications or data without notice Static Pressure - inches of water Static Pressure Pascals (Pa)Alarm signal /17 Alarm signal for speed monitoring. Signal output via open collector. The fan emits a high continuous signal during trouble-free operation within the permissible voltage range. Low signal when speed limit is not reached. After elimination of fault, the fan returns to its desired speed the alarm signal reverts to high. Alarm signal-data 1 Type V DC mA V DC mA V DC mA S min Page 8318 /17 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1500 100 35 8318 /17 H 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1500 100 35 3312 /17 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1500 100 39 3314 /17 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1500 100 39 3318 /17 H 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1500 100 39 4318 /17 M 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1150 100 44 4318 /17 0.4 n < nG 2 60 n > nG 0 60 20 15 * 850 100 44 4214 /17 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1150 100 47 4184 N /17 X 0.4 n < nG 2 60 n > nG 0 60 20 15 * 1500 100 48 Attention: With these fan specials, deviations as regards temperature range, voltage range and power consumption are possible compared with standard fans. Supply Voltage Electrical connection U B Fan Customer (+) Power t UB UB t 2 Speed +UBS n>n n>n n n>n G G G locked -1 n=0min n<n *) G output n G t Isink US (-) Power Alarm Signal U=U AHigh BA U A U ALow t All voltages measured to ground. t2 = Alarm signal suppression during start-up External load resistance Ra from UA to UBA required. * n < speed limit nG by braking or blocking. With VARIOFANs with external temperature sensor for controlling the motor speed, the NTC sensor is not included in the scope of delivery. Temperature sensor LZ 370, see Accessories. 94 Alarm output- voltage UA Low Condition: Condition: I sink = Alarm output- voltage UA High Condition: Condition: Isource Alarm operating- voltage UBA max. Max. permissible Sink current Alarm delay time t2 Condition: Speed limit n G Fan description