Kompaktlfter 2011 EN Final 17 01 2011 :Vorlage 18.01.2011 14:26 Seite 36 3 max. 79 m /h DC axial fans Series 8400 N 80 x 80 x 25 mm Highlights: Ball bearings and sleeve bearings available. Some models suitable for use at high ambient temperatures up to 85 C. General characteristics: Material: fibreglass-reinforced plastic. Impeller PA, housing PBT. Fully integrated electronic commutation. Protected against reverse polarity and locking. Connection via single strands AWG 24, TR 64. Bared and tin-plated. Air exhaust over struts. Direction of rotation counter-clockwise, seen on rotor. Mass: 95 g. Nominal data Nominal data 3 3 Type m /h CFM VDC VDC dB(A) Bel(A) / Watts RPM C Hours Hours P. 110/112 Type m /h CFM VDC VDC dB(A) Bel(A) / Watts RPM C Hours Hours P. 117 8412 NGLE 33 19,4 12 8...15 12 3,5 0,5 1 500 -20...+85 80 000 / 27 500 160 000 1 /2 20 11,8 < 10 < 3 0,9 900 1 8412 NGLV 12 10...14 -20...+70 80 000 / 40 000 160 000 8412 NLE 33 19,4 12 8...15 17 3,7 0,3 1 500 -20...+85 80 000 / 27 500 160 000 1 33 19,4 12 3,5 1,1 1 500 2 8412 NGMLE 45 26,5 12 8...15 19 3,9 0,9 2 050 -20...+80 80 000 / 32 500 160 000 2 27 15,9 < 10 3,0 1,1 1 200 3 8412 NGMLV 12 8...14 -20...+70 80 000 / 40 000 160 000 /37 8412 NMLE 45 26,5 12 8...15 21 4,0 0,6 2 050 -20...+85 80 000 / 27 500 160 000 2 45 26,6 19 3,9 1,5 2 050 4 8412 NGME 58 34,1 12 8...15 26 4,3 1,4 2 600 -20...+75 80 000 / 35 000 160 000 3 /2 35 20,6 < 13 3,5 1,4 1 600 5 8412 NME 58 34,1 12 8...15 27 4,4 1,0 2 600 -20...+75 80 000 / 35 000 160 000 3 8412 NGMI 12 8...14 -20...+70 80 000 / 35 000 125 000 58 34,1 26 4,3 2,0 2 600 6 8412 NG 69 40,6 12 8...15 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 140 000 4 /2 8412 N 69 40,6 12 8...15 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 140 000 4 /2 8412 NH 79 46,5 12 8...13,2 37 5,0 2,2 3 600 -20...+70 70 000 / 35 000 140 000 5 /2/12 8412 NH-217 79 46,5 12 8...15 37 5,0 2,4 3 600 -20...+70 70 000 / 35 000 140 000 5 8414 NGL 33 19,4 24 18...28 12 3,5 0,7 1 500 -20...+70 80 000 / 40 000 160 000 1 /2 8414 NL 33 19,4 24 18...28 17 3,7 0,7 1 500 -20...+70 80 000 / 40 000 160 000 1 8414 NGML 45 26,5 24 18...28 19 3,9 1,1 2 050 -20...+70 80 000 / 40 000 160 000 2 8414 NML 45 26,5 24 18...28 21 4,0 1,1 2 050 -20...+70 80 000 / 40 000 160 000 2 8414 NGM 58 34,1 24 18...28 26 4,3 1,4 2 600 -20...+70 80 000 / 40 000 160 000 3 /2 8414 NM 58 34,1 24 18...28 27 4,4 1,4 2 600 -20...+70 80 000 / 40 000 160 000 3 8414 NG 69 40,6 24 18...28 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 140 000 4 /2 8414 N 69 40,6 24 18...28 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 140 000 4 /2 8414 NH 79 46,5 24 18...26 37 5,0 2,4 3 600 -20...+70 70 000 / 35 000 140 000 5 /2 8414 NH-221 79 46,5 24 18...28 37 5,0 2,4 3 600 -20...+70 70 000 / 35 000 140 000 5 8418 N 69 40,6 48 36...56 32 4,7 2,0 3 100 -20...+70 70 000 / 35 000 140 000 4 5 40 4 30 3 20 2 10 1 0 8 16 24 32 40 CFM 10 20 30 40 50 60 m/h 36 HH NN IIP54P54 AA PP GG PPWWMM TT II Pa in H O 0,05 0,10 0,15 2 Air flow Air flow Nominal voltage Voltage range Sound pressure level Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L (40 C) 10 ebm-papst Standard Service life L (T ) 10 max ebm-papst Standard Life expectancy L 10 (40 C) see P. 15 Curve SpecialsSpeed signal /2 Speed-proportional, square-wave signal for external monitoring of the fan motor speed 2, 3, or 6 pulses per revolution Open-collector signal output Extremely wide operating voltage range Easy adaptation to user interface Connection via separate cable The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or more interconnected fans. Electrical hookup Signal data Type VDC mA VDC mA VDC mA Page V m V m V m 250 250 0.40.4 2 2 3030 0 0 30 30 2 2 2 31 2 31 5 2 0 5 2 2 400 F400 F 0.40.4 1 1 3030 0 0 30 30 2 2 2 32 2 32 5 2 0 6 2 2 400400 0.40.4 1 1 3030 0 0 30 30 2 2 2 33 2 33 5 2 0 6 4 2 420 J420 J 0.40.4 2 2 1515 0 0 15 15 4 4 2 34 2 34 5 2 0 6 2 6 500 F500 F 0.40.4 1 1 3030 0 0 30 30 2 2 2 35 2 35 7 2 0 6 2 2 All voltages measured to ground. External load resistor R / U / U required. 600 F600 F 0.40.4 1 1 3030 0 0 30 30 2 2 2 36 2 36 7 2 0 3 2 2 a S BS 620620 0.40.4 2 2 3030 0 0 30 30 4 4 2 372 37 7 2 0 1 2 2 630 U630 U 0.40.4 2 2 3030 0 0 30 30 4 4 2 38 2 38 6 2 0 6 2 2 600 N600 N 0.40.4 2 2 2828 0 0 28 28 4 4 2 39 2 39 6 2 0 6 2 6 600 J600 J 0.40.4 2 2 3030 0 0 30 30 4 4 2 41 2 41 6 2 0 6 2 6 700 F700 F 0.40.4 2 2 3030 0 0 30 30 4 4 2 42 2 42 6 2 0 6 2 6 84508450 0.40.4 2 2 2828 0 0 28 28 4 4 2 43 2 43 6 2 0 6 2 2 8400 N8400 N 0.40.4 2 2 2828 0 0 28 28 4 4 2 44 2 44 D 2 0 6 2 6 8400 N 8400 N VVARIOFARIOFANAN 0.40.4 2 2 3030 0 0 30 30 4 4 2 45 2 45 2 2 0 6 2 6 83008300 0.40.4 2 2 3030 0 0 30 30 4 4 2 46 2 46 R 2 0 3 4 2 8200 J8200 J 0.40.4 2 2 3030 0 0 30 30 4 4 2 47 2 47 R 2 0 3 4 3400 N3400 N 0.40.4 2 2 2828 0 0 28 28 4 4 2 48 2 48 R 2 0 3 4 2 3400 N 3400 N VVARIOFARIOFANAN 0.40.4 2 2 3030 0 0 30 30 4 4 2 49 2 49 R 2 0 3 4 2 3300 N3300 N 0.40.4 2 2 3030 0 0 30 30 4 4 2 50 2 50 R 2 0 3 4 2 3212 J / 3214 J3212 J / 3214 J 0.40.4 2 2 3030 0 0 30 30 4 4 2 51 2 51 R 2 0 3 4 2 3218 J3218 J 0.40.4 2 2 6060 0 0 60 60 4 4 2 51 2 51 R 3 0 6 4 2 3250 J3250 J 0.40.4 2 2 6060 0 0 60 60 4 4 3 52 3 52 R 2 0 3 2 2 4412 F / 4414 F4412 F / 4414 F 0.40.4 2 2 3030 0 0 30 30 4 4 2 53 2 53 R 2 0 6 2 6 4418 F4418 F 0.40.4 2 2 6060 0 0 60 60 4 4 2 53 2 53 R 2 0 6 2 6 4400 FN4400 FN 0.40.4 2 2 3030 0 0 30 30 4 4 2 552 55 R 2 0 6 2 6 4312 / 43144312 / 4314 0.40.4 2 2 3030 0 0 30 30 4 4 2 56 2 56 R 2 0 6 2 6 43184318 0.40.4 2 2 6060 0 0 60 60 4 4 2 56 2 56 R 2 0 6 2 6 4312 / 4314 4312 / 4314 VVARIOFARIOFANAN 0.40.4 2 2 3030 0 0 30 30 4 4 2 57 2 57 R 2 0 3 4 2 4318 4318 VVARIOFARIOFANAN 0.40.4 2 2 6060 0 0 60 60 4 4 2 57 2 57 R 2 0 6 2 6 44004400 0.40.4 2 2 3030 0 0 30 30 4 4 2 58/59 2 58/59 R 2 0 6 2 6 4100 N4100 N 0.40.4 2 2 3030 0 0 30 30 4 4 2 60 2 60 R 2 0 6 2 6 4100 NHH...NH64100 NHH...NH6 0.40.4 2 2 6060 0 0 60 60 10 10 2 61 2 61 R 2 0 6 2 6 4100 NH7...NH84100 NH7...NH8 0.40.4 2 2 6060 0 0 60 60 20 20 3 62 3 62 R 2 0 6 2 6 DV 4100DV 4100 0.40.4 2 2 3030 0 0 30 30 4 4 2 63 2 63 R 2 0 6 2 6 5200 N5200 N 0.40.4 2 2 3030 0 0 30 30 4 4 2 64 2 64 R 2 0 6 2 6 DV 5200 DV 5200 0.40.4 2 2 3030 0 0 30 30 4 4 2 65 2 65 R 2 0 6 2 6 Subject to changeSubject to change S 168 2016-01 Speed signal U S Low Condition: I sink Speed signal U S High Condition: I source Tach operating voltage U BS max. Admissible sink current I sink max. Pulses per revolution Fan description Basic type