A4D500-AM03-01 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Electrical voltage 1 DANGER 1.5 Safety and protective functions 2 Indicates an imminently hazardous situation which, if not 1.6 Mechanical movement 2 avoided, will result in death or serious injury. Compliance with 1.7 Emission 2 the measures is mandatory. 1.8 Hot surface 2 1.9 Transport 2 WARNING Indicates a potentially hazardous situation which, if not avoided, 1.10 Storage 2 could result in death or serious injury. Exercise extreme 2. PROPER USE 3 caution while working. CAUTION 3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which, if not avoided, 3.1 Product drawing 4 may result in minor or moderate injury or damage of property. 3.2 Nominal data 5 3.3 Data in accordance with ecodesign regulation EU 327/2011 5 NOTE 3.4 Technical features 5 A potentially harmful situation can occur and, if not avoided, can 3.5 Mounting data 6 lead to property damage. 3.6 Transport and storage conditions 6 1.2 Staff qualification 4. CONNECTION AND START-UP 6 The device may only be transported, unpacked, installed, operated, 4.1 Connecting the mechanical system 6 maintained and otherwise used by qualified, trained and authorised 4.2 Connecting the electrical system 6 technical staff. 4.3 Connection in terminal box 7 Only authorised specialists are permitted to install the device, to carry 4.4 Connection screen 9 out a test run and to perform work on the electrical installation. 4.5 Open additional screwed cable glands 10 4.6 Checking the connections 10 1.3 Basic safety rules 4.7 Switch on device 10 4.8 Switching off the device 10 Any safety hazards stemming from the device must be re-evaluated once it is installed in the end device. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 10 The local industrial safety regulations must always be observed when CAUSES AND REMEDIES working on the device. 5.1 Cleaning 11 Keep the workplace clean and tidy. Untidiness in the working area 5.2 Safety test 11 increases the risk of injury. 5.3 Disposal 11 Observe the following when working on the unit: Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 1.4 Electrical voltage Check the electrical equipment of the device at regular intervals, refer to chapter 5.2 Safety test. Replace loose connections and defective cables immediately. DANGER Electrical load on the device Risk of electric shock Stand on a rubber mat if you are working on an electrically charged device. Item no. 10057-5-9970 ENG Revision 98149 Release 2018-07-24 Page 1 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsA4D500-AM03-01 Operating instructions WARNING Do not wear any loose-fitting or dangling clothing or jewellery Terminals and connections have voltage even with a while working on rotating parts. unit that is shut off Protect long hair with a cap. Electric shock 1.7 Emission Wait five minutes after disconnecting the voltage at all poles before opening the device. WARNING CAUTION Depending on the installation and operating conditions, In the event of failure, there is electric voltage at the a sound pressure level greater than 70 dB(A) may arise. rotor and impeller Danger of noise-induced hearing loss The rotor and impeller are base insulated. Take appropriate technical safety measures. Do not touch the rotor and impeller once they are installed. Protect operating personnel with appropriate safety equipment, e.g. hearing protection. CAUTION The motor restarts automatically when operating voltage Also observe the requirements of local agencies. is applied, e.g. after a power failure. 1.8 Hot surface Danger of injury Keep out of the danger zone of the device. CAUTION When working on the device, switch off the mains High temperature at the motor housing supply voltage and secure the latter from being switched on Danger of burn injuries again. Ensure that sufficient protection against accidental contact is Wait until the device stops. provided. Insert the brought-out thermal overload protector into the 1.9 Transport control circuit so that the cooled off motor does not switch on independently after a fault. NOTE Transport of device 1.5 Safety and protective functions Transport the device in its original packaging only. DANGER Secure the device so that it does not slip, e.g. by using a Protective device missing and protective device not clamping strap. functioning Without a protective device there is a risk of serious injury, for 1.10 Storage instance when reaching into the device during operation. Store the device, partially or fully assembled, in the original Operate the device only with a fixed protective device and packaging in a clean, dry and weatherproof place free of vibrations. guard grille. Protect the device against environmental effects and dirt until final The fixed protective device must be able to withstand the installation. kinetic energy of a fan blade that becomes detached at We recommend storing the device for no longer than one year in maximum speed. There must not be any gaps which it is order to guarantee trouble-free operation and longest possible service possible to reach into with the fingers, for example. life. The device is a built-in component. As the operator, you Even devices explicitly intended for outdoor use are to be stored as are responsible for ensuring that the device is secured described prior to commissioning. adequately. Maintain the storage temperature, see Stop the device immediately if a protective device is chapter 3.6 Transport and storage conditions. found to be missing or ineffective. Please make sure that all screwed cable glands are fitted with 1.6 Mechanical movement dummy plugs. DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, dangling items of clothing, jewellery and similar items can become entangled and be pulled into the device. Risk of injury. Item no. 10057-5-9970 ENG Revision 98149 Release 2018-07-24 Page 2 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions