D3G146-HQ13-34 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Electromagnetic radiation 2 death or serious injury if the specified actions are not taken. 1.7 Mechanical movement 2 Compliance with the instructions is imperative. 1.8 Emissions 2 1.9 Hot surface 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Storage 2 death or serious injury if the specified actions are not taken. 2. INTENDED USE 3 Exercise extreme caution while working. CAUTION 3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which can result in 3.1 Product drawing 4 minor or moderate injury or damage to property if the specified 3.2 Nominal data 5 actions are not taken. 3.3 Data according to ErP Directive 5 3.4 Technical description 5 NOTE 3.5 Mounting data 5 A potentially harmful situation can occur and, if not avoided, can 3.6 Transport and storage conditions 6 lead to property damage. 3.7 Electromagnetic compatibility 6 1.2 Staff qualifications 4. CONNECTION AND STARTUP 6 The device may only be transported, unpacked, installed, operated, 4.1 Mechanical connection 6 maintained and otherwise used by suitably qualified, trained and 4.2 Electrical connection 6 authorized technical staff. 4.3 Plug connection 7 Only authorized specialists are permitted to install the device, to carry 4.4 Connection diagram 8 out a test run and to perform work on the electrical installation. 4.5 Checking connections 9 4.6 Switching on the device 9 1.3 Basic safety rules 4.7 Switching off the device 9 The safety hazards associated with the device must be assessed again 5. INTEGRATED PROTECTIVE FEATURES 9 following installation in the final product. Note the following when working on the device: 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 Do not perform any modifications, additions or conversions on the CAUSES AND REMEDIES device without the approval of ebm-papst. 6.1 Cleaning 10 6.2 Safety inspection 10 1.4 Voltage 6.3 Disposal 10 Check the device s electrical equipment at regular intervals see Chapter 6.2 Safety inspection. Replace loose connections and defective cables immediately. DANGER Electrically charged device Risk of electric shock When working on an electrically charged device, stand on a rubber mat. WARNING Live terminals and connections even with device switched off Electric shock Item no. 52429-5-9970 ENU Change 89188 Approved 2016-04-18 Page 1 / 11 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsD3G146-HQ13-34 Operating instructions Wait five minutes after disconnecting the voltage at all poles WARNING before opening the device. Rotating device Long hair and dangling items of clothing, jewelry and the like CAUTION can become entangled and be pulled into the device. Injuries In the event of a fault, the rotor and the impeller will be can result. energized Do not wear any loose-fitting or dangling clothing or jewelry The rotor and the impeller have basic insulation. while working on rotating parts. Protect long hair with a cap. Do not touch the rotor and impeller once installed. 1.8 Emissions CAUTION If control voltage or a stored speed set value is applied, WARNING the motor will restart automatically, e.g. after a power Depending on the installation and operating conditions, failure. the sound pressure level may exceed 70 dB(A). Risk of injury Risk of noise-induced hearing loss Keep out of the device danger zone. Take appropriate technical safety measures. When working on the device, switch off the line voltage Protect operating personnel with appropriate safety and ensure that it cannot be switched back on. equipment such as hearing protection. After working on the device, remove any tools or other Also observe the requirements of local agencies. objects from the device. 1.9 Hot surface 1.5 Safety and protective features CAUTION DANGER High temperature on electronics housing Protective device missing and protective device not Risk of burns functioning Ensure sufficient protection against accidental contact. Without a protective device there is a risk of serious injury, for instance if the hands reach or are sucked into the device during 1.10 Storage operation. Store the device, partially or fully assembled, in a dry and Operate the device only with a fixed protective device and weatherproof manner in the original packaging in a clean environment. guard grille. The fixed protective device must be able to withstand the kinetic energy of a fan blade that becomes Protect the device against environmental effects and dirt until final detached at maximum speed. There must not be any gaps installation. which it is possible to reach into with the fingers, for example. We recommend storing the device for no longer than one year in The device is a built-in component. As the operator, you order to guarantee trouble-free operation and the longest possible are responsible for ensuring that the device is secured service life. adequately. Even devices explicitly intended for outdoor use are to be stored as Stop the device immediately if you notice a missing or described prior to commissioning. ineffective protective device. Maintain the storage temperature, see Chapter 3.6 Transport and storage conditions. 1.6 Electromagnetic radiation Interference from electromagnetic radiation is possible, e.g. in conjunction with open- and closed-loop control devices. If impermissible radiation levels occur following installation, appropriate shielding measures have to be taken by the user. NOTE Electrical or electromagnetic interference after installing the device in customer equipment. Verify that the entire setup is EMC-compliant. 1.7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. Item no. 52429-5-9970 ENU Change 89188 Approved 2016-04-18 Page 2 / 11 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions