D4D225-CC01-02
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG
1. SAFETY REGULATIONS AND NOTES
Bachmhle 2
Please read these operating instructions carefully before starting to work
D-74673 Mulfingen
with the device. Observe the following warnings to prevent malfunctions
Phone +49 (0) 7938 81-0
or physical damage to both property and people.
Fax +49 (0) 7938 81-110
These operating instructions are to be regarded as part of this device.
info1@de.ebmpapst.com
If the device is sold or transferred, the operating instructions must
www.ebmpapst.com
accompany it.
CONTENTS
These operating instructions may be duplicated and forwarded for
information about potential dangers and their prevention.
1. SAFETY REGULATIONS AND NOTES 1
1.1 Levels of hazard warnings
1.1 Levels of hazard warnings 1
These operating instructions use the following hazard levels to indicate
1.2 Staff qualification 1
1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations:
1.4 Electrical voltage 1
DANGER
1.5 Safety and protective functions 2
Indicates an imminently hazardous situation which, if not
1.6 Electromagnetic radiation 2
avoided, will result in death or serious injury. Compliance with
1.7 Mechanical movement 2
the measures is mandatory.
1.8 Emission 2
1.9 Hot surface 2 WARNING
Indicates a potentially hazardous situation which, if not avoided,
1.10 Transport 2
could result in death or serious injury. Exercise extreme
1.11 Storage 2
caution while working.
2. PROPER USE 3
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
3. TECHNICAL DATA 4
may result in minor or moderate injury or damage of property.
3.1 Product drawing 4
3.2 Nominal data 5
NOTE
3.3 Data in accordance with ecodesign regulation EU 327/2011 5
A potentially harmful situation can occur and, if not avoided, can
3.4 Technical features 5
lead to property damage.
3.5 Mounting data 5
3.6 Transport and storage conditions 6 1.2 Staff qualification
The device may only be transported, unpacked, installed, operated,
4. CONNECTION AND START-UP 6
maintained and otherwise used by qualified, trained and authorised
4.1 Connecting the mechanical system 6
technical staff.
4.2 Connecting the electrical system 6
Only authorised specialists are permitted to install the device, to carry
4.3 Connection of the cables 7
out a test run and to perform work on the electrical installation.
4.4 Connection screen 8
4.5 Checking the connections 9
1.3 Basic safety rules
4.6 Switch on device 9
4.7 Switching off the device 9 Any safety hazards stemming from the device must be re-evaluated
once it is installed in the end device.
5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9
The local industrial safety regulations must always be observed when
CAUSES AND REMEDIES
working on the device.
5.1 Cleaning 10 Keep the workplace clean and tidy. Untidiness in the working area
5.2 Safety test 10 increases the risk of injury.
5.3 Disposal 10 Observe the following when working on the unit:
; Do not make any modifications, additions or conversions to the
device without the approval of ebm-papst.
1.4 Electrical voltage
; Check the electrical equipment of the device at regular intervals, refer
to chapter 5.2 Safety test.
; Replace loose connections and defective cables immediately.
DANGER
Electrical load on the device
Risk of electric shock
Stand on a rubber mat if you are working on an electrically
charged device.
Item no. 10889-5-9970 ENG Revision 202174 Release 2018-12-28 Page 1 / 10
ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
Translation of the original operating instructionsD4D225-CC01-02
Operating instructions
WARNING
1.7 Mechanical movement
Terminals and connections have voltage even with a
DANGER
unit that is shut off
Rotating device
Electric shock
Body parts that come into contact with the rotor and impeller
Wait five minutes after disconnecting the voltage at all poles
can be injured.
before opening the device.
Secure the device against accidental contact.
CAUTION
Before working on the system/machine, wait until all
In the event of failure, there is electric voltage at the
parts have come to a standstill.
rotor and impeller
The rotor and impeller are base insulated. WARNING
Rotating device
Do not touch the rotor and impeller once they are installed.
Long hair, dangling items of clothing, jewellery and similar items
CAUTION
can become entangled and be pulled into the device. Risk of
The motor restarts automatically when operating voltage
injury.
is applied, e.g. after a power failure.
Do not wear any loose-fitting or dangling clothing or jewellery
Danger of injury
while working on rotating parts.
Keep out of the danger zone of the device.
Protect long hair with a cap.
When working on the device, switch off the mains
supply voltage and secure the latter from being switched on
1.8 Emission
again.
WARNING
Wait until the device stops.
Depending on the installation and operating conditions,
a sound pressure level greater than 70 dB(A) may arise.
1.5 Safety and protective functions
Danger of noise-induced hearing loss
DANGER
Take appropriate technical safety measures.
Protective device missing and protective device not
Protect operating personnel with appropriate safety
functioning
equipment, e.g. hearing protection.
Without a protective device there is a risk of serious injury, for
Also observe the requirements of local agencies.
instance when reaching into the device during operation.
Operate the device only with a fixed protective device and
1.9 Hot surface
guard grille.
CAUTION
The fixed protective device must be able to withstand the
High temperature at the motor housing
kinetic energy of a fan blade that becomes detached at
Danger of burn injuries
maximum speed. There must not be any gaps which it is
possible to reach into with the fingers, for example.
Ensure that sufficient protection against accidental contact is
provided.
The device is a built-in component. As the operator, you
are responsible for ensuring that the device is secured
1.10 Transport
adequately.
Stop the device immediately if a protective device is
NOTE
found to be missing or ineffective.
Transport of device
Transport the device in its original packaging only.
1.6 Electromagnetic radiation
Secure the device so that it does not slip, e.g. by using a
Interference from electromagnetic radiation is possible, e.g. in conjunction
clamping strap.
with open and closed-loop control devices.
If unacceptable emission intensities occur when the fan is installed,
1.11 Storage
appropriate shielding measures have to be taken by the user.
; Store the device, partially or fully assembled, in the original
NOTE
packaging in a clean, dry and weatherproof place free of vibrations.
Electrical or electromagnetic interferences after
; Protect the device against environmental effects and dirt until final
integrating the device in installations on the customer's
installation.
side.
; We recommend storing the device for no longer than one year in
Verify that the entire setup is EMC compliant.
order to guarantee trouble-free operation and longest possible service
life.
; Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.
; Maintain the storage temperature, see
chapter 3.6 Transport and storage conditions.
Item no. 10889-5-9970 ENG Revision 202174 Release 2018-12-28 Page 2 / 10
ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1@de.ebmpapst.com www.ebmpapst.com
Translation of the original operating instructions