K1G200-AD31-02 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Electromagnetic radiation 2 death or serious injury if the specified actions are not taken. 1.7 Mechanical movement 2 Compliance with the instructions is imperative. 1.8 Emissions 2 1.9 Hot surface 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Transport 2 death or serious injury if the specified actions are not taken. 1.11 Storage 2 Exercise extreme caution while working. 2. INTENDED USE 3 CAUTION Indicates a potentially hazardous situation which can result in 3. TECHNICAL DATA 4 minor or moderate injury or damage to property if the specified 3.1 Product drawing 4 actions are not taken. 3.2 Nominal data 5 3.3 Technical description 5 NOTE 3.4 Mounting data 5 A potentially harmful situation can occur and, if not avoided, can 3.5 Transport and storage conditions 5 lead to property damage. 3.6 Electromagnetic compatibility 5 1.2 Staff qualifications 4. CONNECTION AND STARTUP 6 The device may only be transported, unpacked, installed, operated, 4.1 Mechanical connection 6 maintained and otherwise used by suitably qualified, trained and 4.2 Electrical connection 6 authorized technical staff. 4.3 Connecting the cables 6 Only authorized specialists are permitted to install the device, to carry 4.4 Connection diagram 7 out a test run and to perform work on the electrical installation. 4.5 Checking connections 8 4.6 Switching on the device 8 1.3 Basic safety rules 4.7 Switching off the device 8 The safety hazards associated with the device must be assessed again 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 8 following installation in the final product. CAUSES AND REMEDIES The locally applicable industrial safety regulations are always to be 5.1 Cleaning 9 observed when working on the device. 5.2 Safety inspection 9 Keep the workplace clean and tidy. Untidiness in the work area 5.3 Disposal 9 increases the risk of accidents. Note the following when working on the device: Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage Check the device s electrical equipment at regular intervals see Chapter 5.2 Safety inspection. Replace loose connections and defective cables immediately. WARNING Live terminals and connections even with device switched off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 50898-5-9970 ENU Change 202174 Approved 2018-12-28 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsK1G200-AD31-02 Operating instructions CAUTION 1.8 Emissions If control voltage or a stored speed set value is applied, WARNING the motor will restart automatically, e.g. after a power Depending on the installation and operating conditions, failure. the sound pressure level may exceed 70 dB(A). Risk of injury Risk of noise-induced hearing loss Keep out of the devices danger zone. Take appropriate technical safety measures. When working on the device, switch off the line voltage Protect operating personnel with appropriate safety and ensure that it cannot be switched back on. equipment such as hearing protection. Wait until the device comes to a stop. Also observe the requirements of local agencies. After working on the device, remove any tools or other objects from the device. 1.9 Hot surface 1.5 Safety and protective features CAUTION High temperature on electronics housing DANGER Risk of burns Guard missing and guard not functioning Ensure sufficient protection against accidental contact. Without a guard, hands may become caught up in the device during operation for example, resulting in serious injury. Loose 1.10 Transport parts or items of clothing could be drawn in. The device is a built-in component. As the owner, you are NOTE responsible for ensuring that the device is adequately Transporting the device safeguarded. Operate the device only with a fixed Transport the device in its original packaging only. protective device and guard grill. Secure the device so it cannot slip, e.g. by using a Stop the device immediately if a protective device is lashing strip. found to be missing or ineffective. 1.11 Storage 1.6 Electromagnetic radiation Store the device, partially or fully assembled, in a dry place, Interference from electromagnetic radiation is possible, e.g. in conjunction protected against the weather and free from vibration, in the original with open- and closed-loop control devices. packaging in a clean environment. If impermissible radiation levels occur following installation, appropriate Protect the device against environmental effects and dirt until final shielding measures have to be taken by the user. installation. NOTE We recommend storing the device for no longer than one year in Electrical or electromagnetic interference after installing order to guarantee trouble-free operation and the longest possible the device in customer equipment. service life. Verify that the entire setup is EMC-compliant. Even devices explicitly intended for outdoor use are to be stored as described prior to commissioning. 1.7 Mechanical movement Maintain the storage temperature, see DANGER Chapter 3.5 Transport and storage conditions. Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair and dangling items of clothing, jewelry and the like can become entangled and be pulled into the device. Injuries can result. Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts. Protect long hair with a cap. Item no. 50898-5-9970 ENU Change 202174 Approved 2018-12-28 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions