K3G190-RD45-03 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Electromagnetic radiation 2 death or serious injury if the specified actions are not taken. 1.7 Mechanical movement 2 Compliance with the instructions is imperative. 1.8 Emissions 2 1.9 Hot surface 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Storage 2 death or serious injury if the specified actions are not taken. 2. INTENDED USE 3 Exercise extreme caution while working. CAUTION 3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which can result in 3.1 Product drawing 4 minor or moderate injury or damage to property if the specified 3.2 Nominal data 6 actions are not taken. 3.3 Data according to Commission Regulation (EU) 327/2011 6 3.4 Technical description 6 NOTE 3.5 Mounting data 7 A potentially harmful situation can occur and, if not avoided, can 3.6 Transport and storage conditions 7 lead to property damage. 3.7 Electromagnetic compatibility 7 1.2 Staff qualifications 4. CONNECTION AND STARTUP 7 The device may only be transported, unpacked, installed, operated, 4.1 Mechanical connection 7 maintained and otherwise used by suitably qualified, trained and 4.2 Electrical connection 7 authorized technical staff. 4.3 Connecting the cables 8 Only authorized specialists are permitted to install the device, to carry 4.4 Connection diagram 9 out a test run and to perform work on the electrical installation. 4.5 Checking connections 10 4.6 Switching on the device 10 1.3 Basic safety rules 4.7 Switching off the device 10 The safety hazards associated with the device must be assessed again 5. INTEGRATED PROTECTIVE FEATURES 10 following installation in the final product. The locally applicable industrial safety regulations are always to be 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 10 observed when working on the device. CAUSES AND REMEDIES Keep the workplace clean and tidy. Untidiness in the work area 6.1 Cleaning 11 increases the risk of accidents. 6.2 Safety inspection 11 Note the following when working on the device: 6.3 Disposal 11 Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage Check the device s electrical equipment at regular intervals see Chapter 6.2 Safety inspection. Replace loose connections and defective cables immediately. DANGER Electrically charged device Risk of electric shock When working on an electrically charged device, stand on a rubber mat. Item no. 51200-5-9970 ENU Change 213950 Approved 2020-08-04 Page 1 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsK3G190-RD45-03 Operating instructions WARNING WARNING Live terminals and connections even with device Rotating device switched off Long hair and dangling items of clothing, jewelry and the like Electric shock can become entangled and be pulled into the device. Injuries can result. Wait five minutes after disconnecting the voltage at all poles before opening the device. Do not wear any loose-fitting or dangling clothing or jewelry while working on rotating parts. CAUTION Protect long hair with a cap. In the event of a fault, the rotor and the impeller will be energized 1.8 Emissions The rotor and the impeller have basic insulation. Do not touch the rotor and impeller once installed. WARNING Depending on the installation and operating conditions, CAUTION the sound pressure level may exceed 70 dB(A). If control voltage or a stored speed set value is applied, Risk of noise-induced hearing loss the motor will restart automatically, e.g. after a power Take appropriate technical safety measures. failure. Risk of injury Protect operating personnel with appropriate safety equipment such as hearing protection. Keep out of the devices danger zone. Also observe the requirements of local agencies. When working on the device, switch off the line voltage and ensure that it cannot be switched back on. 1.9 Hot surface Wait until the device comes to a stop. CAUTION After working on the device, remove any tools or other High temperature on electronics housing objects from the device. Risk of burns 1.5 Safety and protective features Ensure sufficient protection against accidental contact. DANGER 1.10 Storage Guard missing and guard not functioning Store the device, partially or fully assembled, in a dry place, Without a guard, hands may become caught up in the device protected against the weather and free from vibration, in the original during operation for example, resulting in serious injury. Loose packaging in a clean environment. parts or items of clothing could be drawn in. Protect the device against environmental effects and dirt until final The device is a built-in component. As the owner, you are installation. responsible for ensuring that the device is adequately safeguarded. Operate the device only with a fixed We recommend storing the device for no longer than one year in protective device and guard grill. order to guarantee trouble-free operation and the longest possible service life. Stop the device immediately if a protective device is found to be missing or ineffective. Even devices explicitly intended for outdoor use are to be stored as described prior to commissioning. 1.6 Electromagnetic radiation Maintain the storage temperature, see Interference from electromagnetic radiation is possible, e.g. in conjunction Chapter 3.6 Transport and storage conditions. with open- and closed-loop control devices. If impermissible radiation levels occur following installation, appropriate shielding measures have to be taken by the user. NOTE Electrical or electromagnetic interference after installing the device in customer equipment. Verify that the entire setup is EMC-compliant. 1.7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. Item no. 51200-5-9970 ENU Change 213950 Approved 2020-08-04 Page 2 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions