K3G280-AU06-B2 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Electromagnetic radiation 2 WARNING 1.7 Mechanical movement 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Emission 2 could result in death or serious injury. Exercise extreme 1.9 Hot surface 2 caution while working. 1.10 Transport 2 CAUTION 1.11 Storage 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 1.12 Disposal 2 NOTE 2. PROPER USE 3 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3. TECHNICAL DATA 4 3.1 Product drawing 4 1.2 Staff qualification 3.2 Nominal data 5 The device may only be transported, unpacked, installed, operated, 3.3 Data according to ErP directive 5 maintained and otherwise used by qualified, trained and authorised technical staff. 3.4 Technical features 5 Only authorised specialists are permitted to install the device, to carry 3.5 Mounting data 5 out a test run and to perform work on the electrical installation. 3.6 Transport and storage conditions 5 1.3 Basic safety rules 3.7 Electromagnetic compatibility 6 Any safety hazards stemming from the device must be re-evaluated 4. CONNECTION AND START-UP 6 once it is installed in the end device. 4.1 Connecting the mechanical system 6 Observe the following when working on the unit: 4.2 Connecting the electrical system 6 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.3 Connection in terminal box 7 4.4 Factory settings 8 1.4 Electrical voltage 4.5 Connection screen 9 Check the electrical equipment of the device at regular intervals, refer 4.6 Checking the connections 10 to chapter 6.2 Safety test. 4.7 Switch on device 10 Replace loose connections and defective cables immediately. 4.8 Switching off the device 10 DANGER Electrical load on the device 5. INTEGRATED PROTECTIVE FUNCTIONS 10 Risk of electric shock 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 11 Stand on a rubber mat if you are working on an electrically CAUSES AND REMEDIES charged device. 6.1 Cleaning 11 WARNING 6.2 Safety test 11 Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 50787-5-9970 ENG Revision 82546 Release 2014-09-01 Page 1 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsK3G280-AU06-B2 Operating instructions CAUTION Do not wear any loose clothing or jewellery while working In the event of failure, there is electric voltage at the on rotating parts. rotor and impeller Protect long hair by wearing a cap. The rotor and impeller are base insulated. 1.8 Emission Do not touch the rotor and impeller once they are installed. CAUTION WARNING If control voltage is applied or a speed setpoint is stored, Depending on the installation and operating conditions, the motor automatically restarts, e.g. after a power failure. a sound pressure level greater than 70 dB(A) may arise. Danger of injury Danger of noise-induced hearing loss Keep out of the danger zone of the device. Take appropriate technical safety measures. When working on the device, switch off the mains Protect operating personnel with appropriate safety supply voltage and secure the latter from being switched on equipment, e.g. hearing protection. again. Also observe the requirements of local agencies. Wait until the device stops. 1.9 Hot surface After working on the device, remove any used tools or other objects from the device. CAUTION High temperature at the electronics enclosure 1.5 Safety and protective functions Danger of burn injuries DANGER Ensure that sufficient protection against accidental contact is Missing safety device and non-functioning safety device provided. If there is no safety device, you could be seriously injured, for 1.10 Transport example if you reach into the running device or your hands are sucked into it. NOTE Operate the device only with a fixed and isolating safety Transport of device protection and a fixed guard grille. Transport the device in its original packaging only. The guard must withstand the kinetic energy of a fan blade Secure the device so that it does not slip, e.g. by using a detaching at maximum speed. clamping strap. The device is a built-in component. You, the owner/ operator, are responsible for providing adequate protection for 1.11 Storage the device. Store the device, partially or fully assembled, in a dry and Shut down the device immediately if you detect a weatherproof manner in the original packing in a clean environment. missing or ineffective protective feature. Protect the device from environmental impacts and dirt until the final 1.6 Electromagnetic radiation installation. We recommend storing the device for a maximum up to one year to Interference from electromagnetic radiation is possible, e.g. in conjunction guarantee proper operation and longest possible service life. with open and closed-loop control devices. If unacceptable emission intensities occur when the fan is installed, Even devices explicitly suited for outdoor use are to be stored as appropriate shielding measures have to be taken by the user. described prior to being commissioned. Maintain the storage temperature, see NOTE chapter 3.6 Transport and storage conditions. Electrical or electromagnetic interferences after integrating the device in installations on the customer s Please make sure that all screwed cable glands are fitted with side. dummy plugs. Verify that the entire setup is EMC compliant. 1.12 Disposal 1.7 Mechanical movement When disposing of the device, please comply with all relevant requirements and regulations applicable in your country. DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. Item no. 50787-5-9970 ENG Revision 82546 Release 2014-09-01 Page 2 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions