pf s Pa AC centrifugal fans - RadiCal Series R2E190 RA 190 mm Highlights: Backward curved 7-blade impeller, single phase motor Thermal overload protector (TOP) wired internally Mounting position: Any Condensate discharge holes: None Ingress protection of IP44 dependent on installation and position Material: Fiberglass reinforced composite Impeller: PA Direction of rotation: Clockwise, seen on rotor Nominal Data o Type CFM VAC Watts RPM C g F R2E190-RA50-21 341.4 115 50/60 Yes 70 2,450 -25...75 1,200 IP44 6 Yes R2E190-RA26-20 347.3 230 50/60 Yes 70 2,500 -25...75 1,200 IP44 1.5 Yes (1) Nominal data at operating point with maximum load. I n Pe L A w R2E190-RA50-21Curves Curves A rpm W dB(A) (115V) Druck p f s Pa fr Rho=1,2kg/m 3 qv cfm 0 50 100 150 200 250 300 350 460 1,85 Measurement: LU-128367 A 1 2750 60 0.53 68 1,8 440 1,75 A 2 2575 63 0.55 64 1,7 Air performance measured 420 1,65 as per: ISO 5801, Installation 400 A 3 2450 66 0.59 60 1,6 1,55 category A, without protection 380 1,5 A 4 2630 62 0.54 65 against accidental contact. 1,45 360 1,4 340 1,35 Suction-side noise levels: A 5 1,3 320 L A as per ISO 13347, L A 1,25 W P A 6 4 300 1,2 measured at 1m distance to 1,15 280 fan axis. A 7 1,1 260 1,05 1 The values given are valid A 8 240 0,95 under the measuring 0,9 220 0,85 A 9 conditions mentioned and may 3 200 0,8 vary accoring to the actual 0,75 A 10 180 0,7 installation situation. 0,65 160 A 11 0,6 140 With any deviation to the 0,55 0,5 A 12 standard set-up, the specific 120 0,45 2 100 0,4 values have to be checked 0,35 A 13 and reviewed once installed 80 0,3 0,25 or fitted. 60 A 14 0,2 40 0,15 For detailed information on A 15 0,1 20 0,05 the measuring set-up, please 1 16 0 0 A contact ebm-papst. 0 50 100 150 200 250 300 350 400 450 500 550 600 qv m 3/h A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 11 A 12 A 13 A 14 A 15 16 A pf s Pa Air flow Nominal voltage pfs E IN H2O Hertz Ball bearings Power input (1) Speed (1) Temperature range Mass Ingress Protection Rating Capacitor UL pfs Pa I n Pe L A w R2E190-RA26-20 Curves A rpm W dB(A) (230V) Druck p f s Pa fr Rho=1,2kg/m 3 qv cfm 0 50 100 150 200 250 300 350 1,95 480 Measurement: LU-125753 AB 1 2720 60 0.27 68 1,9 460 1,85 1,8 AB 2 2635 62 0.27 65 Air performance measured 440 1,75 1,7 420 as per: ISO 5801, Installation AB 3 2500 65 0.29 61 1,65 category A, without protection 400 1,6 A 4 1,55 B 2670 61 0.27 66 380 against accidental contact. 1,5 1,45 360 Suction-side noise levels: A 1,4 5 340 1,35 L A as per ISO 13347, L A W P 1,3 320 A 6 1,25 measured at 1m distance to 4 300 1,2 fan axis. A 7 1,15 280 1,1 1,05 260 The values given are valid A 8 1 240 under the measuring 0,95 3 0,9 A 9 220 conditions mentioned and may 0,85 200 0,8 vary accoring to the actual A 10 0,75 180 installation situation. 0,7 160 0,65 A 11 0,6 With any deviation to the 140 0,55 A 12 standard set-up, the specific 2 0,5 120 0,45 values have to be checked 100 0,4 A 13 0,35 and reviewed once installed 80 0,3 or fitted. A 14 0,25 60 0,2 40 0,15 For detailed information on A 15 0,1 20 the measuring set-up, please 0,05 1 A 16 0 0 contact ebm-papst. 0 50 100 150 200 250 300 350 400 450 500 550 600 650 qv m 3/h R2E190-RAXX-XX ( ) 2.66 68.5 ( ) 2.46 62.5 ( ) 0.08 2 ( ) 0.55 14 + ( 0.2) 2.28 58 ( ) 0.05 1.25 Depth of screw max. 5mm Accessory part: Inlet nozzle 09576-2-4013, not included in the standard scope of delivery A 1 2 Connection line PVC 4G 0.5mm , A 2 4x brass lead tips crimped ( ) 0.08 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 pfs Pa ( ) 3.15 80 ( +0.1) 1.06 27 5.20 (132.2) 7.48 (190) ( ) 4.94 125.5 pfs E IN H2O 0.2(4.5) 4X ( ) 6.22 158 ( ) 6.69 170 ( ) 0.24 6 ( +10) 3.35 85 + ( 20) 17.72 450