pfs Pa AC centrifugal fans - RadiCal Series R2E220 RA 220 mm Highlights: Backward curved 7-blade impeller, single phase motor Thermal overload protector (TOP) wired internally Mounting position: Any Condensate discharge holes: None Ingress protection of IP44 dependent on installation and position Material: Fiberglass reinforced composite Impeller: PA Direction of rotation: Clockwise, seen on rotor Nominal Data o Type CFM VAC Watts RPM C g F R2E220-RA44-14 529.7 115 50/60 Yes 108 2,100 -25...60 1,300 IP44 8 Yes R2E220-RA38-13 541.5 230 50/60 Yes 107 2,050 -25...60 1,300 IP44 2 Yes (1) Nominal data at operating point with maximum load. I n Pe L A w R2E220-RA44-14 Curves Curves A rpm W dB(A) (115V) Druck p f s Pa fr Rho=1,2kg/m 3 qv cfm 0 50 100 150 200 250 300 350 400 450 500 550 500 2 Measurement: LU-130009 A 1 2455 92 0.81 69 480 1,9 460 A 2 2260 98 0.85 62 1,8 Air performance measured 440 as per: ISO 5801, Installation 1,7 A 3 2100 100 0.88 60 420 category A, without protection 400 1,6 A 4 2265 96 0.84 65 against accidental contact. 380 1,5 360 Suction-side noise levels: A 5 1,4 340 L A as per ISO 13347, L A W P A 6 1,3 320 measured at 1m distance to 300 1,2 A fan axis. 7 280 1,1 4 The values given are valid A 8 260 1 240 under the measuring 0,9 A 9 conditions mentioned and may 220 200 0,8 vary accoring to the actual A 10 180 installation situation. 0,7 3 A 11 160 0,6 With any deviation to the 140 A 12 standard set-up, the specific 0,5 120 values have to be checked 100 0,4 A 13 2 and reviewed once installed 80 0,3 or fitted. A 14 60 0,2 40 For detailed information on A 15 0,1 20 the measuring set-up, please A 16 contact ebm-papst. 0 100 200 300 400 500 600 700 800 900 qv m/h A 1 A 2 A 3 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 p fs Pa Air flow Nominal voltage pfs E IN H2O Hertz Ball bearings Power input (1) Speed (1) Temperature range Mass Ingress Protection Rating Capacitor UL pf s Pa I n Pe L A w R2E220-RA38-13 Curves A rpm W dB(A) (230V) Druck p f s Pa fr Rho=1,2kg/m 3 qv cfm 0 50 100 150 200 250 300 350 400 450 500 550 500 2 Measurement: LU-136805 AB 1 2450 102 0.46 69 480 1,9 460 AB 2 2220 106 0.46 62 Air performance measured 1,8 440 as per: ISO 5801, Installation AB 3 1,7 2050 107 0.47 60 420 category A, without protection 400 1,6 AB 4 2215 105 0.46 65 against accidental contact. 380 1,5 360 Suction-side noise levels: A 5 1,4 340 L A as per ISO 13347, L A W P 1,3 A 6 320 measured at 1m distance to 300 1,2 fan axis. A 7 280 1,1 4 The values given are valid A 8 260 1 under the measuring 240 A 9 0,9 conditions mentioned and may 220 vary accoring to the actual 200 0,8 A 10 3 installation situation. 180 0,7 A 11 160 0,6 With any deviation to the 140 A 12 standard set-up, the specific 0,5 120 values have to be checked 2 100 0,4 A 13 and reviewed once installed 80 0,3 or fitted. A 14 60 0,2 40 For detailed information on A 15 0,1 20 the measuring set-up, please 1 A 16 0 0 contact ebm-papst. 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 qv m 3/h R2E220-RAXX-XX ( +1) 2.80 71 ( ) 2.51 63.7 Depth of screw max. 5mm ( ) 0.08 2 Accessory part: Inlet nozzle 09609-2-4013, not included in the standard A 1 scope of delivery Connection line PFA 2 A 2 4G 0.5mm , 4x brass lead tips crimped A 3 ( ) 0.08 2 A 4 A 5 A 6 A 7 A 8 A 9 A 10 A 11 A 12 A 13 A 14 A 15 A 16 ( ) 0.24 6 ( +10) 3.35 85 + ( 20) 17.72 450 +0.2 ( ) 2.28 58 p f s Pa + ( 0.1) 1.06 27 ( ) 6.3 161 8.66 (220) ( ) 6.10 155 0.27(5.5) 4X pfs E IN H2O ( ) 9.53 170 ( ) 9.92 170