R3G190-AB23-02 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Electromagnetic radiation 2 WARNING 1.7 Mechanical movement 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Emission 2 could result in death or serious injury. Exercise extreme 1.9 Hot surface 2 caution while working. 1.10 Storage 2 CAUTION 1.11 Disposal 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 2. PROPER USE 3 NOTE 3. TECHNICAL DATA 4 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3.1 Product drawing 4 3.2 Nominal data 5 1.2 Staff qualification 3.3 Technical features 5 The device may only be transported, unpacked, installed, operated, 3.4 Mounting data 5 maintained and otherwise used by qualified, trained and authorised technical staff. 3.5 Transport and storage conditions 5 Only authorised specialists are permitted to install the device, to carry 3.6 Electromagnetic compatibility 5 out a test run and to perform work on the electrical installation. 4. CONNECTION AND START-UP 6 1.3 Basic safety rules 4.1 Connecting the mechanical system 6 Any safety hazards stemming from the device must be re-evaluated 4.2 Connecting the electrical system 6 once it is installed in the end device. 4.3 Connection of the cables 6 Observe the following when working on the unit: 4.4 Connection screen 7 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.5 Checking the connections 8 4.6 Switch on device 8 1.4 Electrical voltage 4.7 Switching off the device 8 Check the electrical equipment of the device at regular intervals, refer to chapter 6.2 Safety test. 5. INTEGRATED PROTECTIVE FUNCTIONS 8 Replace loose connections and defective cables immediately. 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 CAUSES AND REMEDIES DANGER Electrical load on the device 6.1 Cleaning 9 Risk of electric shock 6.2 Safety test 9 Stand on a rubber mat if you are working on an electrically charged device. WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 50988-5-9970 Revision 82598 Release 2014-05-08 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsR3G190-AB23-02 Operating instructions CAUTION Do not wear any loose clothing or jewellery while working In the event of failure, there is electric voltage at the on rotating parts. rotor and impeller Protect long hair by wearing a cap. The rotor and impeller are base insulated. 1.8 Emission Do not touch the rotor and impeller once they are installed. CAUTION WARNING If control voltage is applied or a speed setpoint is stored, Depending on the installation and operating conditions, the motor automatically restarts, e.g. after a power failure. a sound pressure level greater than 70 dB(A) may arise. Danger of injury Danger of noise-induced hearing loss Keep out of the danger zone of the device. Take appropriate technical safety measures. When working on the device, switch off the mains Protect operating personnel with appropriate safety supply voltage and secure the latter from being switched on equipment, e.g. hearing protection. again. Also observe the requirements of local agencies. Wait until the device stops. 1.9 Hot surface After working on the device, remove any used tools or other objects from the device. CAUTION High temperature at the electronics enclosure 1.5 Safety and protective functions Danger of burn injuries DANGER Ensure that sufficient protection against accidental contact is Missing safety device and non-functioning safety device provided. If there is no safety device, you could be seriously injured, for 1.10 Storage example if you reach into the running device or your hands are sucked into it. Store the device, partially or fully assembled, in a dry and Operate the device only with a fixed and isolating safety weatherproof manner in the original packing in a clean environment. protection and a fixed guard grille. Protect the device from environmental impacts and dirt until the final The guard must withstand the kinetic energy of a fan blade installation. detaching at maximum speed. We recommend storing the device for a maximum up to one year to The device is a built-in component. You, the owner/ guarantee proper operation and longest possible service life. operator, are responsible for providing adequate protection for Even devices explicitly suited for outdoor use are to be stored as the device. described prior to being commissioned. Shut down the device immediately if you detect a Maintain the storage temperature, see missing or ineffective protective feature. chapter 3.5 Transport and storage conditions. 1.6 Electromagnetic radiation 1.11 Disposal Interference from electromagnetic radiation is possible, e.g. in conjunction When disposing of the device, please comply with all relevant with open and closed-loop control devices. requirements and regulations applicable in your country. If unacceptable emission intensities occur when the fan is installed, appropriate shielding measures have to be taken by the user. NOTE Electrical or electromagnetic interferences after integrating the device in installations on the customer s side. Verify that the entire setup is EMC compliant. 1.7 Mechanical movement DANGER Rotating device Body parts that come into contact with the rotor and impeller can be injured. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair, loose items of clothing and jewellery could become entangled and pulled into the device. You could be injured. Item no. 50988-5-9970 Revision 82598 Release 2014-05-08 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions