R3G500-RA25-01 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Electromagnetic radiation 2 WARNING 1.7 Mechanical movement 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Emission 2 could result in death or serious injury. Exercise extreme 1.9 Hot surface 2 caution while working. 1.10 Storage 2 CAUTION 1.11 Disposal 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 2. PROPER USE 3 NOTE 3. TECHNICAL DATA 4 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3.1 Product drawing 4 3.2 Nominal data 5 1.2 Staff qualification 3.3 Data according to ErP directive 5 The device may only be transported, unpacked, installed, operated, 3.4 Technical features 5 maintained and otherwise used by qualified, trained and authorised technical staff. 3.5 Mounting data 5 Only authorised specialists are permitted to install the device, to carry 3.6 Transport and storage conditions 5 out a test run and to perform work on the electrical installation. 3.7 Electromagnetic compatibility 6 1.3 Basic safety rules 4. CONNECTION AND START-UP 6 Any safety hazards stemming from the device must be re-evaluated 4.1 Connecting the mechanical system 6 once it is installed in the end device. 4.2 Connecting the electrical system 6 Observe the following when working on the unit: 4.3 Connection in terminal box 7 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.4 Factory settings 8 4.5 Connection screen 9 1.4 Electrical voltage 4.6 Checking the connections 10 Check the electrical equipment of the device at regular intervals, refer 4.7 Switch on device 10 to chapter 6.2 Safety test. 4.8 Switching off the device 10 Replace loose connections and defective cables immediately. 5. INTEGRATED PROTECTIVE FUNCTIONS 10 WARNING Terminals and connections have voltage even with a 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 11 unit that is shut off CAUSES AND REMEDIES Electric shock 6.1 Cleaning 11 Wait five minutes after disconnecting the voltage at all poles 6.2 Safety test 12 before opening the device. CAUTION In the event of failure, there is electric voltage at the rotor and impeller The rotor and impeller are base insulated. Do not touch the rotor and impeller once they are installed. Item no. 50771-5-9970 ENG Revision 83473 Release 2015-03-10 Page 1 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsR3G500-RA25-01 Operating instructions CAUTION WARNING If control voltage is applied or a speed setpoint is stored, Rotating device the motor automatically restarts, e.g. after a power failure. Long hair, loose items of clothing and jewellery could become Danger of injury entangled and pulled into the device. You could be injured. Keep out of the danger zone of the device. Do not wear any loose clothing or jewellery while working on rotating parts. When working on the device, switch off the mains supply voltage and secure the latter from being switched on Protect long hair by wearing a cap. again. 1.8 Emission Wait until the device stops. After working on the device, remove any used tools or WARNING other objects from the device. Depending on the installation and operating conditions, a sound pressure level greater than 70 dB(A) may arise. 1.5 Safety and protective functions Danger of noise-induced hearing loss Take appropriate technical safety measures. DANGER Missing safety device and non-functioning safety device Protect operating personnel with appropriate safety If there is no safety device, you could be seriously injured, for equipment, e.g. hearing protection. example if you reach into the running device or your hands are Also observe the requirements of local agencies. sucked into it. 1.9 Hot surface Operate the device only with a fixed and isolating safety protection and a fixed guard grille. CAUTION The guard must withstand the kinetic energy of a fan blade High temperature at the electronics enclosure detaching at maximum speed. Danger of burn injuries The device is a built-in component. You, the owner/ Ensure that sufficient protection against accidental contact is operator, are responsible for providing adequate protection for provided. the device. Shut down the device immediately if you detect a 1.10 Storage missing or ineffective protective feature. Store the device, partially or fully assembled, in a dry and weatherproof manner in the original packing in a clean environment. 1.6 Electromagnetic radiation Protect the device from environmental impacts and dirt until the final Interference from electromagnetic radiation is possible, e.g. in conjunction installation. with open and closed-loop control devices. We recommend storing the device for a maximum up to one year to If unacceptable emission intensities occur when the fan is installed, guarantee proper operation and longest possible service life. appropriate shielding measures have to be taken by the user. Even devices explicitly suited for outdoor use are to be stored as NOTE described prior to being commissioned. Electrical or electromagnetic interferences after Maintain the storage temperature, see integrating the device in installations on the customer s chapter 3.6 Transport and storage conditions. side. Please make sure that all screwed cable glands are fitted with Verify that the entire setup is EMC compliant. dummy plugs. 1.7 Mechanical movement 1.11 Disposal DANGER When disposing of the device, please comply with all relevant Rotating device requirements and regulations applicable in your country. Body parts that come into contact with the rotor and impeller can be injured. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. DANGER Flying parts Missing safety devices may cause balancing weights or broken fan blades to be ejected at high speeds, causing bodily harm. Take appropriate safety measures. Item no. 50771-5-9970 ENG Revision 83473 Release 2015-03-10 Page 2 / 12 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions