R4D400-AD22-06 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND NOTES Bachmhle 2 Please read these operating instructions carefully before starting to work D-74673 Mulfingen with the device. Observe the following warnings to prevent malfunctions Phone +49 (0) 7938 81-0 or physical damage to both property and people. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of this device. info1 de.ebmpapst.com If the device is sold or transferred, the operating instructions must www.ebmpapst.com accompany it. CONTENTS These operating instructions may be duplicated and forwarded for information about potential dangers and their prevention. 1. SAFETY REGULATIONS AND NOTES 1 1.1 Levels of hazard warnings 1.1 Levels of hazard warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualification 1 potentially hazardous situations and important safety regulations: 1.3 Basic safety rules 1 DANGER 1.4 Electrical voltage 1 Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Compliance with 1.5 Safety and protective functions 2 the measures is mandatory. 1.6 Electromagnetic radiation 2 WARNING 1.7 Mechanical movement 2 Indicates a potentially hazardous situation which, if not avoided, 1.8 Emission 2 could result in death or serious injury. Exercise extreme 1.9 Hot surface 2 caution while working. 1.10 Transport 2 CAUTION 1.11 Storage 2 Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury or damage of property. 1.12 Disposal 2 NOTE 2. PROPER USE 3 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 3. TECHNICAL DATA 4 3.1 Product drawing 4 1.2 Staff qualification 3.2 Nominal data 5 The device may only be transported, unpacked, installed, operated, 3.3 Data according to ErP directive 5 maintained and otherwise used by qualified, trained and authorised technical staff. 3.4 Technical features 5 Only authorised specialists are permitted to install the device, to carry 3.5 Mounting data 5 out a test run and to perform work on the electrical installation. 3.6 Transport and storage conditions 5 1.3 Basic safety rules 4. CONNECTION AND START-UP 6 Any safety hazards stemming from the device must be re-evaluated 4.1 Connecting the mechanical system 6 once it is installed in the end device. 4.2 Connecting the electrical system 6 Observe the following when working on the unit: 4.3 Connection of the cables 6 Do not make any modifications, additions or conversions to the device without the approval of ebm-papst. 4.4 Connection screen 8 4.5 Checking the connections 9 1.4 Electrical voltage 4.6 Switch on device 9 Check the electrical equipment of the device at regular intervals, refer 4.7 Switching off the device 9 to chapter 5.2 Safety test. Replace loose connections and defective cables immediately. 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 CAUSES AND REMEDIES DANGER 5.1 Cleaning 10 Electrical load on the device Risk of electric shock 5.2 Safety test 10 Stand on a rubber mat if you are working on an electrically charged device. WARNING Terminals and connections have voltage even with a unit that is shut off Electric shock Wait five minutes after disconnecting the voltage at all poles before opening the device. Item no. 11132-5-9970 Revision 82546 Release 2014-05-08 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsR4D400-AD22-06 Operating instructions CAUTION WARNING In the event of failure, there is electric voltage at the Rotating device rotor and impeller Long hair, loose items of clothing and jewellery could become The rotor and impeller are base insulated. entangled and pulled into the device. You could be injured. Do not touch the rotor and impeller once they are installed. Do not wear any loose clothing or jewellery while working on rotating parts. CAUTION Protect long hair by wearing a cap. The motor restarts automatically when operating voltage is applied, e.g. after a power failure. 1.8 Emission Danger of injury Keep out of the danger zone of the device. WARNING Depending on the installation and operating conditions, When working on the device, switch off the mains a sound pressure level greater than 70 dB(A) may arise. supply voltage and secure the latter from being switched on Danger of noise-induced hearing loss again. Take appropriate technical safety measures. Wait until the device stops. Protect operating personnel with appropriate safety Insert the brought-out thermal overload protector into the equipment, e.g. hearing protection. control circuit so that the cooled off motor does not switch on independently after a fault. Also observe the requirements of local agencies. 1.5 Safety and protective functions 1.9 Hot surface DANGER CAUTION Missing safety device and non-functioning safety device High temperature at the motor housing If there is no safety device, you could be seriously injured, for Danger of burn injuries example if you reach into the running device or your hands are Ensure that sufficient protection against accidental contact is sucked into it. provided. Operate the device only with a fixed and isolating safety 1.10 Transport protection and a fixed guard grille. The guard must withstand the kinetic energy of a fan blade NOTE detaching at maximum speed. Transport of device The device is a built-in component. You, the owner/ Transport the device in its original packaging only. operator, are responsible for providing adequate protection for Secure the device so that it does not slip, e.g. by using a the device. clamping strap. Shut down the device immediately if you detect a missing or ineffective protective feature. 1.11 Storage 1.6 Electromagnetic radiation Store the device, partially or fully assembled, in a dry and weatherproof manner in the original packing in a clean environment. Interference from electromagnetic radiation is possible, e.g. in conjunction Protect the device from environmental impacts and dirt until the final with open and closed-loop control devices. installation. If unacceptable emission intensities occur when the fan is installed, appropriate shielding measures have to be taken by the user. We recommend storing the device for a maximum up to one year to guarantee proper operation and longest possible service life. NOTE Even devices explicitly suited for outdoor use are to be stored as Electrical or electromagnetic interferences after described prior to being commissioned. integrating the device in installations on the customer s side. Maintain the storage temperature, see chapter 3.6 Transport and storage conditions. Verify that the entire setup is EMC compliant. 1.12 Disposal 1.7 Mechanical movement When disposing of the device, please comply with all relevant DANGER requirements and regulations applicable in your country. Rotating device Body parts that come into contact with the rotor and impeller can be injured. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. Item no. 11132-5-9970 Revision 82546 Release 2014-05-08 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions