Kompaktlfter 2011 EN Final 17 01 2011 :Vorlage 18.01.2011 14:13 Seite 87 3 max. 209 m /h DC centrifugal fans Series RG 160 N 220 x 220 x 56 mm Highlights: Optional Vario-Pro: Highly adaptable software configuration of the fan enables a tailor-made solution to the specific requirements of your applications. Backward curved impeller. General characteristics: Fibreglass-reinforced plastic scroll housing and impeller Housing base of steel plate. Fully integrated electronic commutation. Protected against reverse polarity and locking. Direction of air flow: axial air intake, centrifugal air exhaust out of the outlet. Connection via single strands AWG 22, TR 64. Bared and tin-plated. 48 V Model: Flat plug 6.3 x 0.8 mm for protective earth. Mass: 1.4 kg. Nominal data 3 Type m /h CFM VDC VDC Bel(A) / Watts RPM C Hours Hours P. 112 RG 160-28/12 NM 139 81,1 12 7...14 5,6 7,5 1 900 -20...+70 80 000 / 40 000 160 000 1 RG 160-28/12 N 209 123,0 12 7,5...14 6,6 21,0 2 850 -20...+70 70 000 / 35 000 140 000 2 /12 RG 160-28/14 NM 139 81,1 24 12...28 5,6 7,0 1 900 -20...+70 80 000 / 40 000 120 000 1 RG 160-28/14 N 209 123,0 24 12...28 6,6 20,0 2 850 -20...+70 70 000 / 35 000 120 000 2 RG 160-28/18 N 209 123,0 48 28...60 6,6 20,0 2 850 -20...+70 70 000 / 35 000 120 000 2 /12 2 350 300 250 200 1 150 100 50 20 0 40 60 80 CFM 25 50 75 100 125 150 m/h 87 HH SS NN IIP54P54 AA PP PP GG PPWWMM TT II Pa in H O 0,2 0,4 0,6 0,8 1,0 1,2 2 Air flow Air flow Nominal voltage Voltage range Sound power level Sintec sleeve bearings Ball bearings Power input Nominal speed Temperature range Service life L (40 C) 10 ebm-papst Standard Service life L (T ) 10 max ebm-papst Standard Life expectancy L 10 (40 C) see P. 15 Curve Specials Representatives Accessories AC centrifugal fans AC axial fans ACmaxx / i-maxx DC fans - specials DC centrifugal fans DC axial fans InformationSpeed signal /12 Speed-proportional, square-wave signal for external monitoring of the fan motor speed 2, 3, or 6 pulses per revolution TTL-compatible Integrated pull-up resistor Connection via separate cable The sensor signal also serves as a major comparison variable for setting and maintaining the setpoint speed for interactive or controlled cooling with one or more interconnected fans. Electrical hookup Signal data Type VDC mA VDC mA mA Page 614 N/12 GM 0.4 1 2.55.5 1 1 39 618 N/12 N 0.4 1 2.55.5 1 1 39 All voltages measured to ground. 8412 N/12 H 0.4 1 2.55.5 1 1 44 4412 F/12 GM 0.4 1 2.55.5 1 1 53 4418 F/12 0.4 1 2.55.5 1 1 53 4312 /12 M 0.4 1 2.55.5 1 1 56 4314 /12 0.4 1 2.55.5 1 1 56 4182 N/12 X 0.4 1 2.55.5 1 1 60 Subject to change Note: With these fan options, deviations in regard to temperature range, voltage range and power consumption are possible compared with standard fan data. 170 2016-01 Speed signal U S Low Condition: I sink Speed signal U S High Condition: I source Admissible sink current I sink max. Fan description Basic type