W1G200-EC87-20 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Electromagnetic radiation 2 death or serious injury if the specified actions are not taken. 1.7 Mechanical movement 2 Compliance with the instructions is imperative. 1.8 Emissions 2 1.9 Transport 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Storage 2 death or serious injury if the specified actions are not taken. 2. INTENDED USE 3 Exercise extreme caution while working. CAUTION 3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which can result in 3.1 Product drawing 4 minor or moderate injury or damage to property if the specified 3.2 Nominal data 5 actions are not taken. 3.3 Technical description 5 3.4 Mounting data 5 NOTE 3.5 Transport and storage conditions 5 A potentially harmful situation can occur and, if not avoided, can 3.6 Electromagnetic compatibility 5 lead to property damage. 4. CONNECTION AND STARTUP 6 1.2 Staff qualifications 4.1 Mechanical connection 6 The device may only be transported, unpacked, installed, operated, 4.2 Electrical connection 6 maintained and otherwise used by suitably qualified, trained and 4.3 Routing of cables 6 authorized technical staff. 4.4 Connection diagram 8 Only authorized specialists are permitted to install the device, to carry 4.5 Checking connections 9 out a test run and to perform work on the electrical installation. 4.6 Switching on the device 9 4.7 Switching off the device 9 1.3 Basic safety rules 5. INTEGRATED PROTECTIVE FEATURES 9 The safety hazards associated with the device must be assessed again following installation in the final product. 6. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 Note the following when working on the device: CAUSES AND REMEDIES Do not perform any modifications, additions or conversions on the 6.1 Cleaning 10 device without the approval of ebm-papst. 6.2 Safety inspection 10 6.3 Disposal 10 1.4 Voltage Check the device s electrical equipment at regular intervals see Chapter 6.2 Safety inspection. Replace loose connections and defective cables immediately. DANGER Electrically charged device Risk of electric shock When working on an electrically charged device, stand on a rubber mat. WARNING Live terminals and connections even with device switched off Electric shock Item no. 50445-5-9970 ENU Change 89436 Approved 2016-10-18 Page 1 / 11 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsW1G200-EC87-20 Operating instructions Wait five minutes after disconnecting the voltage at all poles Do not wear any loose-fitting or dangling clothing or jewelry before opening the device. while working on rotating parts. Protect long hair with a cap. CAUTION If control voltage or a stored speed set value is applied, 1.8 Emissions the motor will restart automatically, e.g. after a power failure. WARNING Risk of injury Depending on the installation and operating conditions, Keep out of the devices danger zone. When working on the sound pressure level may exceed 70 dB(A). the device, switch off the line voltage and ensure that it Risk of noise-induced hearing loss cannot be switched back on. Take appropriate technical safety measures. Wait until the device comes to a stop. Protect operating personnel with appropriate safety After working on the device, remove any tools or other equipment such as hearing protection. objects from the device. Also observe the requirements of local agencies. 1.5 Safety and protective features 1.9 Transport DANGER NOTE Protective device missing and protective device not Transporting the device functioning Transport the device in its original packaging only. Without a protective device there is a risk of serious injury, for instance when reaching into the device during operation. 1.10 Storage Operate the device only with a fixed protective device and Store the device, partially or fully assembled, in a dry place, guard grille. protected against the weather and free from vibration, in the original The fixed protective device must be able to withstand the packaging in a clean environment. kinetic energy of a fan blade that becomes detached at Protect the device against environmental effects and dirt until final maximum speed. There must not be any gaps which it is installation. possible to reach into with the fingers, for example. We recommend storing the device for no longer than one year in The device is a built-in component. As the operator, you order to guarantee trouble-free operation and the longest possible are responsible for ensuring that the device is secured service life. adequately. Even devices explicitly intended for outdoor use are to be stored as Stop the device immediately if you notice a missing or described prior to commissioning. ineffective protective device. Maintain the storage temperature, see 1.6 Electromagnetic radiation Chapter 3.5 Transport and storage conditions. Interference from electromagnetic radiation is possible, e.g. in conjunction with open- and closed-loop control devices. If impermissible radiation levels occur following installation, appropriate shielding measures have to be taken by the user. NOTE Electrical or electromagnetic interference after installing the device in customer equipment. Verify that the entire setup is EMC-compliant. 1.7 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair and dangling items of clothing, jewelry and the like can become entangled and be pulled into the device. Injuries can result. Item no. 50445-5-9970 ENU Change 89436 Approved 2016-10-18 Page 2 / 11 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions