3 Max. 1000 m /h AC axial fans 225 x 80 mm Material: Housing: Die-cast-aluminum Impeller: Sheet steel, painted black Rotor: Painted black Number of blades: 7 Direction of air flow: Direction of rotation: Counterclockwise, looking towards rotor Degree of protection: IP 44, depending on installation and position Insulation class: Installation position: Any Condensation drainage holes: None Mode of operation: Continuous operation (S1) Bearings: Maintenance-free ball bearings Nominal data 3 -1 Type Motor VAC Hz m /h rpm W A F/VDB dB(A) Pa C kg A 1~115 50 880 2550 64 0.58 5.0/220 - 80 -25...+60 2.0 M2E 068-BF P. 263 / A1) W2E 200-HK86-01 B 1~115 60 1000 2800 80 0.70 5.0/220 - 95 -25...+65 2.0 C 1~230 50 880 2550 64 0.29 1.5/450 - 80 -25...+60 2.1 M2E 068-BF P. 263 / A1) W2E 200-HK38-01 D 1~230 60 1000 2800 80 0.35 1.5/450 - 95 -25...+65 2.1 Subject to change n P I L A ed W Curves: -1 rpm W A dB(A) B D A 1 2640 56 0.56 - 100 A 2 2595 58 0.57 - A 3 2550 61 0.58 - A 4 2480 64 0.60 - 80 A C B 1 2980 67 0.58 - B 2 2880 71 0.62 - B 3 2790 75 0.65 - 60 B 4 2660 80 0.69 - C 1 2630 60 0.30 - C 2 2585 64 0.31 - C 3 40 2530 - 66 0.31 C 4 2480 69 0.32 - D 1 3000 70 0.31 - D 2 2935 73 0.32 - 20 D 3 2850 77 0.34 - D 4 2705 83 0.36 - 0 100 200 300 400 500 cfm q 200 400 600 800 m/h v Air performance measured according to: ISO 5801, Installation category A. For detailed information on the measurement setup, contact ebm- papst. Suction-side noise levels: L A according to ISO 13347, L A measured at 1 m distance from fan axis. The values given are applicable only W p under the specified measuring conditions and may differ depending on the installation conditions. In the event of deviation from the standard configuration, the parameters must be checked after installation For detailed information see Motor protection: Thermal overload protector (TOP) connected internally Touch current: < 0.75 mA acc. to IEC 60990 (test circuit, illustration 4) Cable exit: Variable Electrical hookup: Via terminal strips, capacitor connected Protection class: I (with customer connection to grounding conductor) Conformity with standard(s): EN 60335-1, CE A B Approvals: EAC, UL 507, VDE, CSA C22.2 no. 113, CCC C D EAC, UL 2111, VDE, CSA C22.2 no. 113, CCC N L PE N L 240 7 7 0.3 260 80 Finger guards Connection diagrams 221 from p. 245 P. 263 225 +0.2 4.5 (8x) 2016-01 RepresentativesRepresentatives AccessoriesAccessories AC centrifugal fansAC centrifugal fans AC axial fansAC axial fans ACmaxx / EC fansACmaxx / EC fans DC fans - specialsDC fans - specials DC centrifugal fansDC centrifugal fans DC axial fansDC axial fans InformationInformation