CrCrCrCryyyyssssttttaaaal unl unl unl unitititit MHz RANGE CRYSTAL UNIT SMD MA - 406 MA - 505 / MA - 506 Frequency range : 4 MHz to 64 MHz Thickness : 3.7 mm Max.(MA-406) Actual size : 4.6 mm Max.(MA-505 / 506) Overtone order : Fundamental MA-406 MA-505 / 506 3rd overtone(30 MHz to 64 MHz) Applications : For Clock of integrated circuit Specifications (characteristics) Item Symbol Specifications Remarks 4.000 MHz to 29.999 MHz Fundamental *1 Nominal frequency range f 30.000 MHz to 64.000 MHz 3rd overtone *2 Temperature Storage temperature T stg -55 C to +125 C Store as bare product after unpacking range Operating temperature T use -20 C to +70 C Please contact us on availability of -40 C to +85 C Level of drive DL 10 W to 100 W -6 Frequency tolerance (standard) f tol 50 10 +25 C -6 Frequency versus temperature characteristics Under 5.5 MHz :50 10 -20 C to +70 C f tem -6 (standard) Over 5.5 MHz :30 10 For the out of standard specifications, please contact us for inquires Fundamental: 10 pF to Load capacitance CL Overtone: 5 pF to Please specify Motional resistance (ESR) R1 As per below table -20 C to +70 C, DL=100 W Shunt capacitance C0 5 pF Max. -6 Frequency aging f age 5 10 / year Max. +25 C,First year *1 4.0 MHz f < 5.5 MHz : See Available frequencies from 4.0 MHz to less than 5.5 MHz. 8.0 MHz < f < 8.2 MHz: Unavailable. *2 26.000 MHz f <30.000 MHz :please contact us for inquiries for 3rd overtone mode. Available frequency from 4.0 MHz to less than 5.5 MHz (MHz) 4.000 4.032 4.096 4.190 4.194304 4.433619 4.500 4.800 4.9152 Motional resistance (ESR) Frequency (MHz) 4.0 f < 5.5 5.5 f < 6.0 6.0 f <10.0 10.0 f < 12.0 12.0 f < 16.0 16.0 f < 30.0 30.0 f 36.0 36.0 < f 64.0 Motional resistance 150 Max. 100 Max. 80 Max. 60 Max. 50 Max. 40 Max. 100 Max. 80 Max. Overtone order Fundamental 3rd overtone External dimensions (Unit:mm) . MA-406 MA-505 / 506 11.7 Max. Internal connection in MA-505 4 3 4 3 Internal connection 3 4 20.000M 1 2 4 3 16.934M E 5251A E 572 1 2 Internal connection in MA-506 4 3 12.70 2 1 1 2 13.46 Max. 1 2 0.7 1.09 1.09 9.6 2.1 (1.2) (1.2) 2.54 2.54 Do not connect 2 and 3 to external device. 3.3 Metal may be exposed on the top or bottom of this product. Do not connect 2 and 3 of MA-506 to external device. This will not affect any quality, reliability or electrical spec. The first digit of lot No. means : 5 MA-505 6 MA-506 Footprint (Recommended) (Unit:mm) MA-406 MA-505 MA-506 4.1 7.0 4.1 4.1 7.0 4.1 1.8 7.8 1.8 3D STRATEGY EPSON TOYOCOM In order to meet customer needs in a rapidly advancing digital, Quartz devices have become crucial in the network environment broadband and ubiquitous society, we are committed to offering where products are increasingly intended for broadband, products that are one step ahead of the market and a rank above ubiquitous applications and where various types of terminals can the rest in quality. To achieve our goals, we follow a 3D (three transfer information almost immediately via LAN and WAN on a device) strategy designed to drive both horizontal and vertical global scale. Epson Toyocom Corporation addresses every single growth. We will to grow our three device categories of Timing aspect within a network environment. The new corporation offers Devices, Sensing Devices and Optical Devices, and expand Digital Convergence solutions to problems arising with products vertical growth through a combination of products from these for consumer use, such as, core network systems and automotive categories. systems. PROMOTION OF ENVIRONMENTAL MANAGEMENT SYSTEM CONFORMING TO INTERNATIONAL STANDARDS At Epson Toyocom, all environmental initiatives operate under the Plan-Do-Check-Action(PDCA) cycle designed to achieve continuous improvements. The environmental management system (EMS) operates under the ISO 14001 environmental management standard. All of our major manufacturing and non-manufacturing sites, in Japan and overseas, completed the acquisition of ISO 14001 certification. In the future, new group companies will be expected to acquire the certification around the third year of operations. ISO 14000 is an international standard for environmental management that was established by the International Standards Organization in 1996 against the background of growing concern regarding global warming, destruction of the ozone layer, and global deforestation. WORKING FOR HIGH QUALITY Epson Toyocom quickly began working to acquire company-wide ISO 9000 series certification, and has acquired ISO 9001 or ISO 9002 certification for all targeted products manufactured in Japanese and overseas plants. Epson Toyocom has acquired QS-9000 certification, which is of a higher level. Also, TS 16949 certification, which is also of a higher level, has been acquired. QS-9000 is an enhanced standard for quality ISO/TS 16949 is a global standard based on assurance systems formulated by leading QS-9000, a severe standard corresponding to U.S.automobile manufacturers based on the requirements from the automobile industry. the international ISO 9000 series. Notice This material is subject to change without notice. Any part of this material may not be reproduced or duplicated in any form or any means without the written permission of Epson Toyocom. The information, applied circuitry, programming, usage, etc., written in this material is intended for reference only. Epson Toyocom does not assume any liability for the occurrence of infringing on any patent or copyright of a third party. This material does not authorize the licensing on for any patent or intellectual copyrights. Any product described in this material may contain technology or the subject relating to strategic products under the control of the Foreign Exchange and Foreign Trade Law of Japan and may require an export license from the Ministry of International Trade and Industry or other approval from another government agency. These products are intended for general use in electronic equipment. When using them in specific applications that require extremely high reliability, such as the applications stated below, you must obtain permission from Epson Toyocom in advance. / Space equipment (artificial satellites, rockets, etc.) / Transportation vehicles and related (automobiles, aircraft, trains, vessels, etc.) / Medical instruments to sustain life / Submarine transmitters / Power stations and related / Fire work equipment and security equipment / traffic control equipment / and others requiring equivalent reliability. In this new crystal master for Epson Toyocom, product codes and markings will remain as previously identified prior to the merger. Due to the on-going strategy of gradual unification of part numbers, please review product codes and markings, as they will change during the course of the coming months. We apologize for the inconvenience, but we will eventually have a unified part numbering system for Epson Toyocom that will be user friendly.