SERIES JC AND JCA ENGINEERING DATA SHEET RELAY - NONLATCH 1 PDT, 25 AMP All welded construction 1 PDT Contact arrangement Qualified to MIL-PRF-6106 PRINCIPLE TECHNICAL CHARACTERISTICS Contacts rated at 28 Vdc 115 Vac, 400 Hz, 1 0.10lb max Weight Dimensions 1.01in x .51in x 1.00in (JC) 1.01in x .51in x 1.12in (JCA) Special models available upon request. Hermetically sealed, corrosion resistant metal can. APPLICATION NOTES: 101 (JC) 102 (JCA) 103E 007 APPLICABLE SOCKETS: SO-1063-9033/9034 CONTACT ELECTRICAL CHARACTERISTICS Contact rating per pole Load current in Amps and load type 1 28 Vdc 115 Vac, 400 Hz, 1 115/200 Vac, 60 Hz, 1 9 Resistive 6 25 25 2.5 Inductive 5 12 15 2.5 Motor 10 10 2 Lamp 4 4 1 Overload 50 80 N/A Rupture 60 100 N/A AMERICAS EUROPE ASIA 6900 Orangethorpe Ave. 2 Rue Goethe Units 602-603 6/F Lakeside 1 P.O. Box 5032 57430 Sarralbe No.8 Science Park West Avenue Buena Park, CA 90622 France Phase Two, Hong Kong Science Park Featuring LEACH power and control solutions Pak Shek Kok, Tai Po, N.T . Hong Kong www.esterline.com Tel: (01) 714-736-7599 Tel: (33) 3 87 97 31 01 Tel: (852) 2 191 3830 Fax: (01) 714-670-1145 Fax: (33) 3 87 97 96 86 Fax: (852) 2 389 5803 Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component. Date of issue: 06/10 - 146 - Page 1 of 4 COIL CHARACTERISTICS (Vdc) SERIES JC AND JCA CODE A B C M N 7 E F J K (VDC) (VDC) (VDC) (VDC) (VDC) (400 Hz) (400 Hz) (50 Thru 400 Hz) (50 Thru 400 Hz) Nominal operating voltage 28 12 6 48 28 28 115 28 115 Maximum operating voltage 29 14.5 7.3 50 29 30 122 30 122 Maximum pickup voltage - Cold coil at +125 C 18 9 4.5 36 18 22 90 23 95 - During high temp test at +125 C 19.8 9.9 5 38 19.8 24.4 95.4 24.6 100 Drop-out voltage (maximum) 7 4.5 2.5 14 7 10 30 10 30 .240A .040A .100A .024A Coil resistance 10% +25 C or 320 80 20 1000 320 max coil current (Amps) at +25 C +20% +10% GENERAL CHARACTERISTICS Temperature range -70C to 125C Minimum operating cycles (life) at rated load 50,000 Minimum operating cycles (life) at 25% rated load 200,000 Dielectric strength at sea level - All circuits to ground and circuit to circuit 1250 Vrms - Coil to ground 1000 Vrms Dielectric strength at altitude 80,000 ft 500 Vrms 2 Insulation resistance - Initial (500 Vdc) 100 M min - After environmental tests (500 Vdc) 50 M min Sinusoidal vibration (A, D and J mounting) 0.12DA / 10 to 70 Hz 30G / 70 to 3000 Hz Random vibration - Applicable specification MIL-STD-202 - Method 214 2 - Test condition - A, D, and J mounting 1G (0.4G /Hz, 50 to 2000 Hz) - Duration 15 minutes each plane Shock (A, D and J mounting) 200G / 6 ms Maximum contact opening time under vibration and shock 10 s Operate time at nominal voltage (either coil) - Series JC 10 ms max - Series JCA 15 ms max Release time at nominal voltage (either coil) - Series JC 10 ms max - Series JCA 50 ms max Contact make bounce at nominal voltage 25C 1 ms max Contact release break bounce at nominal voltage 25C 0.1 ms max 8 Weight maximum 0.10lb Unless otherwise noted, the specified temperature range applies to all relay characteristics. Date of issue: 06/10 - 147 - Page 2 of 4