SERIES X ENGINEERING DATA SHEET RELAY - NONLATCH 2 PDT, LOW LEVEL TO 5 AMP Contact arrangement 2 PDT MIL-PRF-6106 Qualified to PRINCIPLE TECHNICAL CHARACTERISTICS Low level, 28 Vdc and 115/200 Vac, Contacts rated at 400Hz 3, case grounded 0.034lb max Weight Dimensions .41in x .81in x .64in Special models available upon request. Hermetically sealed, corrosion resistant metal can. APPLICATION NOTES: 101 102 103A 007 023 APPLICABLE SOCKETS: SO-1064-001 SM-1000-003 CONTACT ELECTRICAL CHARACTERISTICS Contact rating per pole Load current in Amps and load type 1 28 Vdc 115 Vac, 400 Hz, 1 115/200 Vac, 400 Hz, 3 Resistive 5 5 5 Inductive 2 3 5 5 Motor 2 3 3 Lamp 1 1 - Overload 20 30 30 Rupture 25 40 40 Low level 3 - - - Time current characteristics 4 - - - AMERICAS EUROPE ASIA 6900 Orangethorpe Ave. 2 Rue Goethe Units 602-603 6/F Lakeside 1 P.O. Box 5032 57430 Sarralbe No.8 Science Park West Avenue Buena Park, CA 90622 France Phase Two, Hong Kong Science Park Featuring LEACH power and control solutions Pak Shek Kok, Tai Po, N.T . Hong Kong www.esterline.com Tel: (01) 714-736-7599 Tel: (33) 3 87 97 31 01 Tel: (852) 2 191 3830 Fax: (01) 714-670-1145 Fax: (33) 3 87 97 96 86 Fax: (852) 2 389 5803 Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component. Date of issue: 9/07 - 53 - Page 1 of 4 COIL CHARACTERISTICS (Vdc) SERIES X CODE A B C M N 5 R 5 V 5 Nominal operating voltage 28 12 6 48 28 12 6 Maximum operating voltage 29 14.5 7.3 50 29 14.5 7.3 Maximum pickup voltage - Cold coil at +125 C 18 9 4.5 36 18 9 4.5 - During high temp test at +125 C 19.8 9.9 5 38 19.8 9.9 5 - During continuous current test at +125 C 22.5 11.25 5.7 42 22.5 11.25 5.7 Maximum drop-out voltage 7 4.5 2.5 14 7 7 2.5 500 125 20 1600 500 125 20 Coil resistance in 10% at +25 C, except types and +20%, -10% 20% GENERAL CHARACTERISTICS Temperature range -70C to +125C Minimum operating cycles (life) at rated load 100,000 Minimum operating cycles (life) at 25% rated load 400,000 Dielectric strength at sea level - All circuits to ground and circuit to circuit 1000 Vrms - Coil to ground 1000 Vrms Dielectric strength at altitude 80,000 ft 500 Vrms 6 Insulation resistance - Initial (500 Vdc) 100 M min - After environmental tests (500 Vdc) 50 M min Sinusoidal vibration (A, D and J mounting) 0.12DA / 10 to 70 Hz 30G / 70 to 3000 Hz Sinusoidal vibration (E mounting in track) 0.06DA / 10 to 57 Hz 10G /57 to 500 Hz 20G / 500 to 3000 Hz Sinusoidal vibration (G mounting) 0.12DA / 10 to 57 Hz 20G /57 to 3000 Hz Random vibration - Applicable specification MIL-STD-202 - Method 214 2 - Test condition - A, D and J mounting 1G (0.4g /Hz, 50 to 2000 Hz) 2 - Test condition - E and G mounting (E in track) 1E (0.2G /Hz, 50 to 2000 Hz) - Duration 15 minutes each plane Shock (A, D and J mounting) 200G / 6 ms Shock (E mounting in track) 50G / 11 ms Shock (G mounting) 100G / 6 ms Maximum contact opening time under vibration and shock 10 s Operate time at nominal voltage 25C 4 ms max Release time at nominal voltage 25C 4 ms max Contact make bounce at nominal voltage 25C 0.5 ms max Contact release break bounce at nominal voltage 25C 0.1 ms max 7 Weight maximum 0.034lb Unless otherwise noted, the specified temperature range applies to all relay characteristics. Date of issue: 9/07 - 54 - Page 2 of 4