ECE The Name You Can Trust RADIAL LEADED PTC E175689 Pending LX/LU MODEL FEATURES z Low hold current, Solid state z Radial-leaded product ideal for up to 265VAC/265VDC z Operation current: 0.05A~2.00A z Maximum voltage: 240VAC/VDC z Maximum interrput voltage: 265VAC/DC z Temperature range: -40 to 85 z Cured, flame retardant epoxy polymer insulating material meets UL 94V-0 requirement Bulk packing, tape and reel available on most models APPLICATIONS z Power Supply z Power Transformer z 240VDC/VAC Equipment PART NUMBERING SYSTEM ERF XX XXX XX X X X Z: RoHS Compliant Special number: 0: Standard product Packing type: 0: bulk 2: tape & reel Voltage rating: V2: 240V Current rating: 012: 0.12A Model: LX: Radial leaded devices, low hold current (Disc type) LU: Radial leaded devices, low hold current (Rectangle type) Product Name: Resettable Fuse Marking system ECE EXCEL CELL ELECTRONIC LOGO ECE LX LX012 Current Rating 09AB Model RoHS Compliant Example Date Code/Lot Number NOTE: Specifications subject to change without prior notice. 1 For the latest product information, Please visit our website at www.ece.com.tw ECE The Name You Can Trust Electrical characteristics(23) Resistance Hold Trip Max. Time Maximum Rated Typical Tolerance Part Current Current to trip Current Voltage Power RMIN R1MAX Number IH, A IT, A at 5xIH IMAX, A VMAX, Vdc Pd, W LX005-V2 0.05 0.12 15.0 1.0 240 0.70 18.50 65.0 LX008-V2 0.08 0.19 15.0 1.2 240 0.80 7.40 26.0 LX012-V2 0.12 0.30 15.0 1.2 240 1.00 3.00 12.0 LX016-V2 0.16 0.37 15.0 2.0 240 1.40 2.50 7.80 LU025-V2 0.25 0.56 18.5 3.5 240 1.50 1.30 3.80 LU033-V2 0.33 0.74 18.5 4.5 240 1.70 0.83 2.60 LU040-V2 0.40 0.90 24.0 5.5 240 2.00 0.60 1.90 LU055-V2 0.55 1.25 26.0 7.0 240 3.40 0.45 1.45 LU075-V2 0.75 1.50 18.0 7.5 240 2.60 0.32 0.84 LX100-V2 1.00 2.00 21.0 10.0 240 2.90 0.22 0.58 LX125-V2 1.25 2.50 23.0 12.5 240 3.30 0.17 0.44 LU200-V2 2.00 4.00 28.0 20.0 240 4.50 0.09 0.22 IH=Hold current-maximum current at which the device will not trip at 23 still air. IT=Trip current-minimum current at which the device will always trip at 23 still air. V MAX=Maximum voltage device can withstand without damage at its rated current. I MAX= Maximum fault current device can withstand without damage at rated voltage (V max). Pd=Typical power dissipated from device when in the tripped state in 23 still air environment. RMIN=Minimum device resistance at 23. R1MAX=Maximum device resistance at 23 1 hour after tripping . Typical Time-To-Trip at 23 A=LX005-V2 A B C D E F G H I J K L B=LX008-V2 1000 C=LX012-V2 100 D=LX016-V2 E=LU025-V2 10 F=LU033-V2 G=LU040-V2 1 H=LU055-V2 E=LU075-V2 0.1 F=LX100-V2 0.01 G=LX125-V2 0.1 1 10 100 H=LU200-V2 Fault current (A) NOTE: Specifications subject to change without prior notice. 2 For the latest product information, Please visit our website at www.ece.com.tw Time-to-trip (s)