Ericsson Ericsson Internal Internal E PRODUCT TABLE OF CONTESPECIFICATION NTS 1 1 (1)(4) PrPreparepareedd ((aallsso o ssubjubjecectt rreesponsisponsibbllee iiff othotheerr)) NNoo EZHIXZH SEC/S Kevin Zhou 1/1301001 52-EN/L-BMR662 ZT 146 42Uen 0 Uen Technical Specication ApprApprovoved ed CChecked hecked DDate ate RReevv RRefereferencence e EN/LZT 146 420 R3A March 2014 PKB 4000A series Direct Converters MICRF 2010-05-06 2011-02-24 B C Ericsson AB Input 36-72 V, Output up to 30 A / 125 W Key Features Industry standard low profile Eighth-brick 58.4 x 22.7 x 8.50 mm (2.30 x 0.894 x 0.339 in) High efficiency, typ. 93.3% at 5.0 Vout half load 2250 Vdc input to output isolation Meets isolation requirements equivalent to basic insulation according to IEC/EN/UL 60950 More than 4.3 million hours MTBF General Characteristics Output over voltage protection Input under voltage shutdown Over temperature protection Monotonic startup Output short-circuit protection Remote sense Remote control Safety Approvals Design for Environment Output voltage adjust function Highly automated manufacturing ensures quality ISO 9001/14001 certified supplier Meets requirements in high- temperature lead-free soldering processes. Contents Ordering Information .............................................................2 General Information .............................................................2 Safety Specification .............................................................3 Absolute Maximum Ratings ............................................................. 4 Electrical Specification 3.3 V, 30 A / 99 W PKB 4910A .......................................... 5 5.0 V, 25 A / 125 W PKB 4111A .......................................... 9 EMC Specification ...........................................................13 Operating Information ...........................................................14 Thermal Consideration ...........................................................15 Connections ...........................................................16 Mechanical Information ...........................................................17 Soldering Information ...........................................................19 Delivery Information ...........................................................20 Product Qualification Specification ...........................................................21 Ericsson Internal E PRODUCT SPECIFICATION 2 (4) Prepared (also subject responsible if other) No. SEC/S Kevin Zhou 1/1301-BMR662 Uen 2 Technical Specication Approved Checked Date Rev Reference EN/LZT 146 420 R3A March 2014 PKB 4000A series Direct Converters MICRF 2011-02-24 C Ericsson AB Input 36-72 V, Output up to 30 A / 125 W Ordering Information Ericsson Power Modules fulfills and will continuously fulfill Product program Output all its obligations under regulation (EC) No 1907/2006 PKB 4910A 3.3 V, 30 A / 99 W concerning the registration, evaluation, authorization and PKB 4111A 5.0 V, 25 A / 125 W restriction of chemicals (REACH) as they enter into force and is through product materials declarations preparing for Product number and Packaging the obligations to communicate information on substances PKB 4XXXXA n n n 1 2 3 in the products. n Options n n 3 1 2 Mounting Quality Statement Remote Control logic The products are designed and manufactured in an industrial environment where quality systems and methods Lead length like ISO 9000, Six Sigma, and SPC are intensively in use to boost the continuous improvements strategy. Infant Options Description mortality or early failures in the products are screened out and they are subjected to an ATE-based final test. n PI Through hole * 1 Conservative design rules, design reviews and product SI Surface mount qualifications, plus the high competence of an engaged n Negative * work force, contribute to the high quality of the products. 2 P Positive Warranty n 5.30 mm * 3 Warranty period and conditions are defined in Ericsson LA 3.69 mm Power Modules General Terms and Conditions of Sale. LB 4.57 mm Example a through-hole mounted, negative logic, short pin product would be PKB 4910A PILA. Limitation of Liability Ericsson Power Modules does not make any other * Standard variant (i.e. no option selected). warranties, expressed or implied including any warranty of merchantability or fitness for a particular purpose General Information (including, but not limited to, use in life support Reliability applications, where malfunctions of product can cause injury to a persons health or life). The failure rate () and mean time between failures (MTBF= 1/) is calculated at max output power and an Ericsson AB 201 operating ambient temperature (T ) of +40C. Ericsson A Power Modules uses Telcordia SR-332 Issue 2 Method 1 to The information and specifications in this technical calculate the mean steady-state failure rate and standard specification is believed to be correct at the time of publication. However, no liability is accepted for deviation (). inaccuracies, printing errors or for any consequences thereof. Ericsson AB reserves the right to change the Telcordia SR-332 Issue 2 also provides techniques to contents of this technical specification at any time without estimate the upper confidence levels of failure rates based prior notice. on the mean and standard deviation. Mean steady-state failure rate, Std. deviation, 233 nFailures/h 34.6 nFailures/h MTBF (mean value) for the PKB-A series = 4.3 Mh. MTBF at 90% confidence level = 3.6 Mh Compatibility with RoHS requirements The products are compatible with the relevant clauses and requirements of the RoHS directive 2002/95/EC and have a maximum concentration value of 0.1% by weight in homogeneous materials for lead, mercury, hexavalent chromium, PBB and PBDE and of 0.01% by weight in homogeneous materials for cadmium. Exemptions in the RoHS directive utilized in Ericsson Power Modules products are found in the Statement of Compliance document.