Fluke 116 HVAC Multimeter with Temperature and Microamps Technical Data Compact true-rms meter for HVAC troubleshooting The Fluke 116 was specifically designed for the HVAC professional. It has every- thing needed in an HVAC meter including temperature and microamp measure- ments to quickly troubleshoot problems with HVAC equipment and flame sensors. Features include: Built in thermometer for HVAC applications Microamps to test flame sensors LoZ: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak) CAT III 600 V safety rated General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ( % of reading + counts ) Maximum voltage between any 600 V terminal and earth ground Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Actual size Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Operating temperature -10 C to + 50 C Storage temperature -40 C to + 60 C Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight R N10140Accuracy specifications Measurement Range Resolution Accuracy ( % of reading + counts ) Ordering DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 information DC volts 6.000 V 0.001 V 60.00 V 0.01 V 0.5 % + 2 Fluke-116 HVAC Multimeter with Temperature 600.0 V 0.1 V and Microamps Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) Included 4.0 % + 3 (500 Hz to 1 kHz) TL75 Test Leads, 80BK Integrated 1 AC millivolts 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) Temperature Probe, holster, Users true-rms 2.0 % + 3 (500 Hz to 1 kHz) manual and 9 V battery (installed). 1 AC volts true-rms 6.000 V 0.001 V 1.0 % + 3 (45 Hz to 500 Hz) 60.00 V 0.01 V 2.0 % + 3 (500 Hz to 1 kHz) 600.0 V 0.1 V Continuity 600 1 Beeper on < 20 off > 250 detects opens or shorts of 500 s or longer. Ohms 600.0 0.1 0.9 % + 2 6.000 k 0.001 k 60.00 k 0.01 k 0.9 % + 1 600.0 k 0.1 k 6.000 M 0.001 M 40.00 M 0.01 M 1.5 % + 2 Diode test 2.000 V 0.001 V 0.9 % + 2 Capacitance 1000 nF 1 nF 10.00 F 0.01 F 1.9 % + 2 100.0 F 0.1 F 9999 F 1 F 100 F to 1000 F 1.9 % + 2 > 1000 F 5 % + 20 Lo-Z capacitance 1 nF to 500 F 10 % + 2 typical 2 2 Temperature -40 C to 400 C 0.1 C 1 % + 10 (Type-K 2 thermocouple) -40 F to 752 F 0.2 F 1 % + 18 AC amps 600.0 A 0.1 A 1.5 % + 3 (2.5 % + 3 > 500 Hz) true-rms (45 Hz to 500 Hz) DC amps 600.0 A 0.1 A 1.0 % + 2 Fluke. Keeping your world 3 Hz (V or A input) 99.99 Hz 0.01 Hz up and running. 999.9 Hz 0.1 Hz 0.1 % + 2 9.999 kHz 0.001 kHz Fluke Corporation PO Box 9090, Everett, WA USA 98206 50.00 kHz 0.01 kHz Fluke Europe B.V. Notes: PO Box 1186, 5602 BD 1 All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. Eindhoven, The Netherlands Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non- For more information call: zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 In the U.S.A. (800) 443-5853 or at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. Fax (425) 446-5116 2 Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. In Europe/M-East/Africa (31 40) 2 675 200 or 3 Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: