700P04 PRESSURE MODULE RANGE 100 PSIG 700 kPa 7 bar RANGE 15 PSID/G 100 kPa 1 bar 700P06 PRESSURE MODULE 700 Series Dual-Range and Vacuum Pressure Modules Instruction Sheet Low Differential High Gage is1f.eps Introduction The Fluke 700PDX Series Pressure Modules measure positive and negative pressure. The 700PVX modules measure vacuum. The 700PDX modules work with the Fluke 700 Series Documenting Process Calibrators. The 700PVX modules work only with the 740 Series Calibrators. Read this sheet before you use the pressure module. This sheet contains specifications and information about how to avoid damaging the pressure module. See the calibrators Users Manual for operating instructions. Note If you are using a Fluke-701 or Fluke-702, software V1.3 or higher is required. See specification footnote 1. The pressure module measures pressure or vacuum using an internal microprocessor. It receives operating power from and sends digital information to the calibrator. Gage pressure modules have one pressure fitting and measure pressure with respect to atmospheric pressure. Differential pressure modules have two pressure fittings and measure the difference between the applied pressure on the high fitting versus the low fitting. A differential pressure module functions like a gage module when the low fitting is open. PN 602513 July 1996 Rev.3, 11/01 1996-2001 Fluke Corporation. All rights reserved. Printed in USAPRESSURE MODULE 700P 04 RANGE 15 PSID/G 100 kPa 1 bar Box Contents Avoiding Mechanical Damage Pressure module, strap, 1/4 NPT to 1/4 ISO metric adapters To avoid damaging the pressure module, never apply more (one for gage, two for differential), and instruction sheet. than 10 ft.-lbs. of torque between the pressure module fittings or between the fittings and the body of the module. Always apply appropriate torque between the pressure module fitting Protecting Yourself from Pressure Releases and connecting fittings or adapters. Figure 1 shows the To avoid a violent release of pressure in a pressurized correct way and incorrect ways to use a wrench when system, shut off the isolation valve and slowly bleed off the applying torque to the pressure module fitting. pressure before you attach or remove the pressure module from the pressure line. Avoiding Overpressure Damage Applying pressure in excess of the BURST PRESSURE specified on the pressure module can destroy the pressure module. Burst pressure is 3X full scale. is2f.eps Figure 1. 1 Table 1. Specifications (% of full scale) 2 Model Range Gage or Isolated or Reference Stability Temp Total 3 Differential Nonisolated Uncertainty (1 Year) (0 to Uncertainty (23 3 C) 50 C) Fluke-700PD2 -1 to 1.0000 psi Differential Isolated 0.150% 0.025% 0.025% 0.200% -6.89 to 6.8900 kPa -6.89E-2 to 6.89 E-2 bar Fluke-700PD3 -5 to 5.0000 psi Differential Isolated 0.040% 0.015% 0.015% 0.070% -34 to 34.000 kPa -0.34 to 0.3400 bar Fluke-700PD4 -15 to 15.000 psi Differential Isolated 0.025% 0.010% 0.015% 0.050% -100 to 100.00 kPa -1 to 1.0000 bar Fluke-700PD5 -15 to 30.000 psi Gage Isolated 0.025% 0.010% 0.015% 0.050% -100 to 200.00 kPa -1 to 2.0000 bar Fluke-700PD6 -15 to 100.00 psi Gage Isolated 0.025% 0.010% 0.015% 0.050% -100 to 700.00 kPa -1 to 7.0000 bar Fluke-700PD7 -15 to 200.00 psi Gage Isolated 0.040% 0.015% 0.015% 0.070% -100 to 1400.0 kPa -1 to 14.000 bar Fluke-700PV3 0 to -5.0000 psi Differential Isolated 0.040% 0.015% 0.015% 0.070% 0 to -34.000 kPa 0 to -0.3400 bar Fluke-700PV4 0 to -15.000 psi Differential Isolated 0.040% 0.015% 0.015% 0.070% 0 to -100.00 kPa 0 to -1.0000 bar 1. Use of the pressure zero function is required to achieve these specifications. Contact your Fluke Service Center for upgrade of your Fluke 701 or Fluke 702 V1.0, V1.1, or V1.2 Calibrator. (PV3 and PV4 not compatible with the 701 and 702.) 2 2. Available pressure units (psi, kPa, bar, inHg, mmHg, inH 0, ftH 0, kg/cm , mmH 0) are determined by the calibrator being used. 2 2 2 3. Accuracy specifications apply for 1 year for full span from 0 C to 50 C. Typical uncertainty is 1% of full span from -10 C to 0 C. 4. Maximum non-destructive pressure: 3X maximum rated pressure, including common mode pressure. 5. Maximum common mode pressure: 3X maximum rated pressure. 6. Specifications reflect a confidence interval of 95%.