Page 1 of 2, Document 2228 80i-110s AC/DC Current Probe 2002 Fluke Corporation Rev. A-9/2002 80i-110s AC/DC Current Probe The ideal current probe for Fluke ScopeMeter Test Tools Technical Data Accurate current measurements become more and more critical when troubleshooting electric, electronic, and automotive cir- cuits. The Fluke 80i-110s AC/DC Current Probe is designed to provide you with safe, high accuracy measurements for a wide range of applications. The specially designed built- in safety features such as the 600 V rms rating at the input jaws, output cable, and BNC connector enhance work safety in industrial and commercial power distribution systems. The probe is shielded for high noise immunity, to prevent unwanted noise when trou- under test. This makes it diffi- Supply (UPS), that uses a bleshooting around noise gen- cult to get an accurate wave- battery backup system. erating devices like adjustable form measurement. With its narrow jaw design, speed motor drives and ignition The wide measurement the Fluke 80i-110s makes it systems. range from 50 milliamps to 100 easy to take measurements in The 80i-110s accurately Amps with a high fidelity milli- tight spots. reproduces current waveforms volt output gives you full as they occur. Connect the advantage of the high resolu- Specifications clamp to a Fluke ScopeMeter tion oscilloscope displays. This Test Tool or other waveform gives you the true picture of Electrical specifications recording device like a Fluke your current situation, and Current ranges: Power Harmonics Analyzer, to allows useful measurements as 0 to 10 A dc or ac peak clearly see distorted waveforms low as 10 milliamps. 0 to 100 A dc or ac peak Output signals: that result from non-linear loads The broad band frequency 10 A range: 100 mV/A such as computers, adjustable response of the Fluke 80i-110s 100 A range: 10 mV/A speed motor drives, and elec- AC/DC Current Probe from dc to Working voltage tronic ballasts for fluorescent 100 kHz supports a wide range (clamp jaws to ground): lighting. of applications where the probe 600 V ac rms on Installation Category II per IEC 1010-1 Current clamps, not specifi- can be used. The probe can be circuits. cally designed for oscilloscopes, used to track down leakage 300 V ac rms on Installation may add distortion to the actual currents discharging car batter- Category III per IEC 1010-1 signal present in the system ies or to measure dc currents circuits. in an Uninterruptible PowerPage 2 of 2, Document 2228 80i-110s AC/DC Current Probe 2002 Fluke Corporation Rev. A-9/2002 Floating voltage (output Battery indicator (ON): General specifications cable and connector to Green LED dims when battery Dimensions: ground): voltage is below 6.5V 67 x 231 x 36 mm 600 V ac rms on Installation Overload indicator (OL): (2.6 x 9.1 x 1.4 inches) Category II per IEC 1010-1 Red LED indicates that wave- Weight: 330 g (11.6 oz), battery circuits. form or impulse is out of range included 300 V ac rms on Installation Output cable: Category III per IEC 1010-1 Instrument compatibility 1.6 meters (63 inches) circuits. Maximum conductor size: The 80i-110s is compatible Basic accuracy (dc to 1 kHz) 11.8 mm (.46 inch) with any Fluke ScopeMeter Test Error (after zero check) Maximum jaw opening: Tool, Power Harmonics Input current dc or ac peak 100 mV/A 10 mV/A 12.5 mm (.49 inch) Analyzer, Oscilloscope, 50 mA to 10 A < 3 % of reading Temperature: Multimeter, or other voltage + 50 mA Operating: 0 C to 50 C measurement device that has 50 mA to 40 A < 4 % of reading (32 F to 122 F) the following features: + 50 mA Non-operating: -30 C to 70 C BNC input connector. A 40 to 80 A < 12 % of reading (-22 F to 158 F) BNC-to-banana adapter + 50 mA Relative humidity (operating): (order PM 9081/001 from 80 to 100 A < 15 % of reading 0 to 85 % (0 C to 35 C 32 F Fluke) can also be used with to 95 F) standard inputs on a digital Extended accuracy: 0 to 45 % (35 C to 50 C multimeter (DMM). For other frequencies, refer to 95 F to 122 F) Input accuracy of 2 % or the appropriate input current Altitude: better to take full advantage range and add the error listed Operating: 0 to 2,000 meters of the accuracy of the probe. below to the Basic Accuracy. (0 to 6,560 feet) Input impedance of greater Additional error Non-operating: 0 to 12,000 than or equal to 1 M in Frequency 100 mV/A 10 mV/A meters (0 to 40,000 feet) parallel with a maximum of 1 to 5 kHz 3 % 3 % 100 pF. 5 to 20 kHz 12 % 12 % A passband of more than Safety specification > 20 kHz Not specified Not specified four times the frequency Designed to meet the require- of the waveform to be Phase shift, dc to 65 Hz: ments of IEC 1010 and CSA- measured. 10 A range < 1.5 degree C22.2 No. 1010.1: Installation 100 A range < 1 degree Category II, Working Voltage Warranty Input load impedance 600V, Pollution Degree 2. (of host instrument): Installation Category III, One-year warranty > 1 M in parallel with up to Working Voltage 300V, 100 pF Pollution Degree 2. Useful bandwidth (-3 dB): Installation (Overvoltage) 0 to 100 kHz Category II refers to local Rise or fall time: < 4 msec level, appliances, and portable Output noise level: equipment. Ordering information 10 mV/A typ. 480 mV pk-pk Installation (Overvoltage) 100 mV/A typ. 3 mV pk-pk Category III refers to distribu- Model Maximum non-destructive tion level and fixed installation 80i-110s AC/DC Current Probe current: circuits inside a building 0 to 2 kHz 140 A peak electrical service entrance. 2 to 10 kHz 110 A peak Designed to meet the 10 to 20 kHz 70 A peak requirements of UL1244, 20 to 50 kHz 30 A peak Protection Class II Double Fluke. Keeping your world 50 to 100 kHz 20 A peak Insulation. up and running. Temperature coefficient: 2000 ppm/C max. for tempera- Battery information Fluke Corporation ture from 0 C to 50 C (32 F to PO Box 9090, Everett, WA USA 98206 Battery: 9 volt, IEC 6LR61 132 F) Fluke Europe B.V. Consumption: 8.6 mA typical All Electrical Specifications are valid at a PO Box 1186, 5602 BD 12 mA maximum temperature of 3 C to 23 C (5 F to 73 F) Eindhoven, The Netherlands Service life: For more information call: 55 hours typical, when Alkaline In the U.S.A. (800) 443-5853 or IEC 6LR61 is used Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or 40 hours minimum, when Fax (31 40) 2 675 222 Alkaline IEC 6LR61 is used In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: