LIMITED WARRANTY & LIMITATION OF LIABILITY This product will be free from defects in material and workmanship for one year from the date of purchase. This warranty does not cover damage from accident, neglect, misuse or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on 90i-610s behalf of the supplier. To obtain service during the warranty period, send your defective product to the nearest Fluke Authorized Service Center with a description of the problem. AC/DC Current Probe THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. THE SUPPLIER IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR Instruction Sheet LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. INTRODUCTION Fluke Corporation, Fluke Industrial B.V., The 90i-610s is a clamp-on AC/DC Current Probe designed to measure current waveforms in P.O. Box 9090, P.O. Box 90, automotive applications with any Test Tool capable of millivolt measurements. There are two Everett WA 98206-9090, U.S.A. 7600 AB, Almelo, The Netherlands. measurement ranges: 0 to 100 A (output voltage 10 mV/A) and 0 to 600 A (output voltage 1 mV/A). SERVICE CENTERS SAFETY INFORMATION To locate an authorized service center, visit Fluke on the World Wide Web: Accuracy: SYMBOLS Input Current Error Error (after zero check) May be used on HAZARDOUS LIVE conductors. (DC or AC peak) 10 mV/A 1 mV/A 0 to 100 A 2 % of reading 1 A 3.5 % of reading 3 A Product is protected by double insulation. 100 to 400 A -- 2.0 % of reading 2 A 400 to 600 A -- 3.0 % of reading 2 A Risk of Danger. Important information. See Users Manual. Maximum Nondestructive Current: 800 A peak Risk of Electric Shock. Input Load Impedance (of host instrument): >1 M in parallel with up to 100 pF Useful Bandwidth: DC and 40 to 400 Hz. Complies with relevant European standards. Dimensions: 73 x 215 x 27 mm (2.9 x 8.4 x 1.1 inches) Weight: 400 g (14 oz.), battery included Earth ground Temperature: operating: 0 to 50 C (32 to 122 F), max humidity 75% nonoperating: -20 to 60 C Battery (-4 to 140 F), max humidity 80% Altitude: operating: 0 to 2000 meters (0 to 6500 feet) nonoperating: 0 to 12000 meters (0 to 40000 UNPACKING feet) The following items should be included in the box of your Current Probe: Temperature Coefficient: AC/DC Current Probe 90i-610s 0.2 * accuracy/ C max. for temperature T<18 C and T>28 C (T<64 F and T>82 F) Instruction sheet (This document) Battery Life: With Alkaline IEC 6LR61, 60 hours typical, 40 hours minimum. 9V Battery, Type IEC 6LR61 BNC-to-Banana Adapter PM9081/001 POWER AND DEMAGNETIZING Check the contents of the shipping box for completeness. If something in the box has been During normal operation the green ON-indicator flashes the red LOW-indicator is on when battery damaged or is missing, contact your distributor immediately. voltage is low. INSTALLING THE BATTERY WARNING WARNING To avoid false readings which could cause injury, replace battery as soon as the red Low Battery Indicator LED lights. To avoid electrical shock, unclamp the Current Probe from any conductor, and Auto power off automatically switches the Probe off after 30 minutes. disconnect the Probes BNC connector from the Test Tool or any other To Demagnetize the Probe, open and close the jaws several times. measurement tool before installing or replacing the battery. Refer to Figure 1 and proceed as follows: CLEANING AND STORAGE Put the Current Probe in the OFF position. Periodically wipe the case with a damp cloth and detergent do not use abrasives or solvents. Open The battery cover is present in the bottom side of the Probe body. Loosen the screw in the the jaws and wipe the magnetic pole pieces with a lightly oiled cloth. Do not allow rust or corrosion to battery cover with a small crossheaded screwdriver. form on the magnetic core ends. Remove the battery if the Probe is not used for periods of longer Slide the battery cover away from the Current Probe. than 60 days. Install the 9V battery (IEC 6LR61). Arrange the battery leads so that they will not be pinched MEASUREMENT INSTRUCTIONS between Probe body and the battery cover. Refer to Figure 2 and proceed as follows: Reinstall the battery cover and secure the screw. Connect the Current Probe to Input A or the volts and COM inputs of the Test Tool. SPECIFICATIONS If necessary use the PM9081 adapter that is supplied with the Probe: for correct polarity, the red leg of the adapter must be inserted into Input A or volts input and the black into COM. All Electrical Specifications are valid at a temperature of 23C 5C (73F 9F). On the Current Probe: select range. Ensure that the green ON-indicator flashes the red Current Ranges: 0 to 100 A DC or AC peak, 0 to 600 A DC or AC peak. LOW-indicator must be off. Output Signals: 100 A range: 10 mV/A / 600 A range: 1 mV/A Adjust the Test Tool to current readout at a sensitivity of 10 mV/A or 1 mV/A and current AC + Measurement Category Ratings: DC measurement. For the proper settings see the user documentation of the Test Tool. 300 V CAT III & 600 V CAT II, pollution degree 2 per EN 61010-1 & EN 61010-02-032. Zero the Probe, especially after you have selected another measurement range. Complies with American industry standards UL61010B-1 & UL61010B-2-032, and European nd Clamp the Current Probe around the conductor. The + and indications marked on the jaw of standards EN/IEC 61010-1 2 Edition & EN/IEC 61010-02-032. the Probe must correspond with the orientation of the current to be measured. This assures a correct reading of the current flow. Observe the current value and the shape of the waveform on the display of the Test Tool.