How to Contact Fluke Before You Start To contact Fluke, call one of the following telephone The installation may be carried out by using either an numbers: electro-hydraulic hole punch (Figure 1, Item 1) or a Technical Support USA: 1-800-44-FLUKE circular hole saw (Figure 2, Item 1). CLKT, CLKTO, CLV (1-800-443-5853) Infrared Window Calibration/Repair USA: 1-888-99-FLUKE 1 2 2 (1-888-993-5853) 1 Installation Guide 1 Canada: 1-800-36-FLUKE (1-800-363-5853) 2 Europe: +31 402-675-200 Introduction Japan: +81-3-3434-0181 The Infrared Window is a precision made accessory Singapore: +65-738-5655 which, when accurately installed, will give years of trouble Anywhere in the world: +1-425-446-5500 free service. Read and understand these instructions thoroughly before attempting to install the units. Or, visit Flukes website at 6. Installation instructions (1) 3 4 5 7. Mounting frame (1) CLKT INFRARED WINDOW Step 2: Fit the Drilling Template onto a Flat Surface Having decided on the correct position for the unit, select TYPE: 3, 12 INDOOR / OUTDOOR USE FLK-075-CLKT the drilling template. Peel off the back and stick to the panel with the wording horizontal (Figure 4). Step 3: Center Punch CLKT, CLKTO, CLV Infrared Window Installation Guide The Infrared Window is a precision made accessory which, when accurately installed, will give years of trouble Using the center punch, punch the fixing holes and free service. Read and understand these instructions thoroughly before attempting to install the units. All of the items in Table 1 are available from Fluke. Table 1. Model Application Voltage Level Type Size center hole as marked (Figure 5). 6 7 CLKT Outdoor All 3, 12 2, 3, 4 CLKTO Indoor Medium 1 3 Step 4: Drill Center Hole PN 3783652 June 2010 IMPORTANT Using the 6 mm (1/4) twist drill, drill out the center hole TAG NO. change without notice. All rights reserved. Printed in UK. CHECK BEHIND BEFORE DRILLING (B) (Figure 6). For 50 mm (2) unit, proceed to step 5. Getting Started For 75 mm (3) and 100 mm (4) units, proceed to step 6. Step 1: Unpack and Check Step 5: Drill Fixing Holes When your Infrared Window arrives, carefully unpack the Using the 2.78 mm (7/64) twist drill, drill out the fixing unit. 8 9 holes (Figure 7). Remove the two front security screws and lay out If using hole saws, proceed to step 7(A). the components. Check that you have all of the parts If using the hole punch, proceed to step 8(A). (Figure 3). Step 6: Drill Fixing Holes 1. Security screws (2) Using the 3.57 mm (9/64) twist drill, drill out the fixing 2. Security cover (1) holes (Figure 8). 3. 2-hole gasket (1) If using hole saws, proceed to step 7(A). 4. Fixing screws (various) If using the hole punch, proceed to step 8(A). 5. Drilling template (1)