Fluke 114 Electrical Multimeter Technical Data Compact true-rms meter for electrical troubleshooting The Fluke 114 is the troubleshooting tool for go/no-go testing. It includes a feature to prevent false readings caused by ghost voltage. Features include: AutoVolt: automatic ac/dc voltage selection Large white LED backlight to work in poorly lit areas Resistance and continuity Min/Max/Average to record signal fluctuations CAT III 600 V safety rated General specifications Accuracy is specified for 1 year after calibration, at operating temperatures of 18 C to 28 C, with relative humidity at 0 % to 90 %. The accuracy specifications take the form of: ( % of Reading + Counts ) Maximum voltage between 600 V any terminal and earth ground Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4/sec Bar graph 33 segments, updates 32/sec Actual size Operating temperature -10 C to + 50 C Storage temperature -40 C to + 60 C Battery 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery life 400 hours typical, without backlight R N10140Accuracy specifications Measurement Range Resolution Accuracy ( % of reading + counts ) DC millivolts 600.0 mV 0.1 mV 0.5 % + 2 DC volts 6.000 V 0.001 V 60.00 V 0.01 V 0.5 % + 2 600.0 V 0.1 V Auto volts 600.0 V 0.1 V 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) 1 AC millivolts true-rms 600.0 mV 0.1 mV 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1 AC volts true-rms 6.000 V 0.001 V 1.0 % + 3 (dc, 45 Hz to 500 Hz) 60.00 V 0.01 V 2.0 % + 3 (500 Hz to 1 kHz) 600.0 V 0.1 V Continuity 600 W 1 W Beeper on < 20 W, off > 250 W detects opens or shorts of 500 s or longer. Ohms 600.0 W 0.1 W 0.9 % + 2 6.000 kW 0.001 kW 60.00 kW 0.01 kW 0.9 % + 1 600.0 kW 0.1 kW 6.000 MW 0.001 MW 40.00 MW 0.01 MW 1.5 % + 2 Notes: 1 All ac voltage ranges are specified from 1 % to 100% of range. Because inputs below 1 % of range are not specified, it is normal for this and other true-rms meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. For volts, crest factor of 3 at 4000 counts, decreasing linearly to 1.5 at full scale. AC volts is ac-coupled. Auto-V LoZ, and ac mV are dc-coupled. Fluke. Keeping your world up and running. Ordering Information Fluke Corporation Fluke-114 Electrical Multimeter PO Box 9090, Everett, WA USA 98206 Fluke Europe B.V. Included PO Box 1186, 5602 BD TL75 Test leads, holster, Users manual Eindhoven, The Netherlands and 9 V battery (installed). For more information call: In the U.S.A. (800) 443-5853 or Fax (425) 446-5116 In Europe/M-East/Africa (31 40) 2 675 200 or Fax (31 40) 2 675 222 In Canada (800)-36-FLUKE or Fax (905) 890-6866 From other countries +1 (425) 446-5500 or Fax +1 (425) 446-5116 Web access: