Fluke 1650B Series Multifunction Installation Testers Extended Specifications The installation testing solution for demanding environments The Fluke 1650B Series testers, with new the user to measure loop impedance with- advanced features, are the perfect instal- out tripping RCDs, eliminating the need to lation testing tool for verifying the safety bypass them. Slim reach probes allow you to of electrical installations in domestic, com- keep your eyes on the panel while probing mercial, and industrial applications. Ensure hard to reach areas. With easy-to-operate that fixed wiring is correctly installed and controls, a large display with a wide viewing compliant with IEC 60364, HD 384 require- angle, padded neck strap, and a compact, ments, and all relevant local standards. The ergonomic design, these testers are com- 1650B Series is efficient to use by allowing fortable enough to use for all day testing. 1651B 1652B 1653B C ompac t , l ight weight a nd c om- S ele c t v olt ag e mea s u r ement H igh r e s olut ion mea s u r ement s for t a ble to wea r q u ic k ly a nd ea s i ly b et we en dow n to 0.01 oh m for a h igh S i mple op er at ion for fa s t , ea s y L - N, L - P E , a nd N - P E level of ac c u r ac y te s t i ng D ua l d i splay g ives si multa neou s Us er s ele c t a ble s a fet y v olt ag e r eadout of m a i n s volt age a nd le v el of 5 0 V or 25 V for v a r ie d Fa s t h igh c u r r ent lo op te s t ( h igh c u r rent mode ) f r e q uenc y env i ron ment s Adva nc e d lo op te s t i ng pr event s Auto d i s c h a r ge a l low s fa s t a nd Rot a r y k nob l a b el i ng av a i l a ble s a fe d i s c h a r g e of ele c t r ic a l i n s i x v er s ion s . E ngl i s h , F r enc h , RC Ds from t r ippi ng ener g y i n c apac it ive c i r c u it s Ger m a n , It a l i a n , S pa n i s h a nd a Va r i a ble RC D c u r r ent mo de for u s er-f r iend ly s y m b ol s ver s ion c u s tom i z e d s et t i ng s A dde d s a fet y t h r ough l ive c i r- c u it dete c t ion , to c he c k a nd Per for m g r ou nd te s t s w it h au x- Z er o ad apter for ea s y te s t lead i n h i bit te s t i f c i r c u it u nder te s t i lia r y ea r t h spi kes eli m inating c ompen sat ion i s l ive t he ne e d for mu lt iple i n s t r u- T he PA S S / FA I L i nd ic ator t a ke s W i r i ng c on ne c t ion c he c k i nd i- ment s (1653 only ) t he g ue s s w ork out of RC D c at ion a nd l ive c i r c u it dete c t ion D ow n load up to 50 0 s tor e d te s t i ng for adde d s a fet y r e s u lt s w it h I R p or t a nd ad apter I n s ulat ion tes t voltages Ti me sav i ng auto -nul l feat u re for profe s s ion a l r ep or t i ng (16 51: 25 0 V, 5 0 0 V, 10 0 0 V ) , (16 5 3 on ly ) s u bt ract s lead resi s ta nc e from (16 52: 25 0 V, 5 0 0 V, 10 0 0 V ) , mea s u r ement s , a nd s tor e s it i n D et ac h a ble lead s for ea s y (16 5 3: 5 0 V, 10 0 V, 25 0 V, memor y e v en a f ter p o wer i ng r epl ac ement 50 0 V, 10 0 0 V ) for a v a r iet y of dow n appl ic at ion s E N - 61557 a nd V DE 0 413 c ompl i a ntSpecifications Features by Model Measurement Function 1651B 1652B 1653B Voltage & Frequenc y Wiring polarity checker Insulation Resistanc e Continuity & Resistanc e L oop & L ine Resistanc e Prospective Earth Fault Current (P E F C / IK) Prospective Short- Circuit current (PS C / IK) RCD sw itching time RCD tripping level ramp test ramp test RCD variable current Automatic RCD test sequenc e Test pulse current sensitive RCDs (Type A) Earth Resistanc e Phase Sequenc e Indicator Other Features Self-test Illuminated Display Memory, Interface Memor y Computer Interfac e Time and date (When used w ith FlukeView software) Software Optional Included Accessories Hard case Remote c ontrol prob e 1 Zero Adapter Note 1 Included w ith all 165XB versions exc ept 1651B U K Version . General Specifications Specification Characteristic Size 10 c m (L) x 25 c m (W) x 12.5 c m (H) Weight (w ith batteries) 1.5 kg Batter y size, quantity Type A A, 6 ea . Batter y type Alkaline supplied . Usable w ith 1.2 V NiCd or NiM H batteries (not supplied) Batter y life (typical) 200 hours idling F use T3.15 A, 500 V, 1.5 kA 6.3 x 32 mm (P N 2030 852) Operating Temperature -10 C to 40 C Storage Temperature -10 C to 6 0 C indefinitely (to -40 C for 100 hrs) Relative Humidity Nonc ondensing <10 C 95 % 10 to 30 C 75 % 30 to 40 C Operating Altitude 0 to 2000 meters Shock, Vibration Vibration to Class 3 per Mil- Prf-288 00F 1 meter drop test, six sides, oak floor Sealing I P 40 E M C Complies w ith E N61326-1: 200 6 Safety Complies w ith E N61010-1 Ed 2.0 (2001-02), U L61010, A N S I / I S A -s82.02.01 2000 and C A N / C S A c22.2 No .1010 2nd edition Over voltage Categor y I I I (C AT I I I), 6 00 V Measurement Categor y I I I is for measurements performed in the building installation . Examples are distribution panels, c ircuit breakers, w iring and cabling . Performanc e E N61557-1, E N61557-2, E N61557-3, E N61557-4, E N61557-5, E N61557-6, E N61557-7 Sec ond edition . E N61557-10 First edition . Maximum voltage b etween 500 V any terminal and earth g round Surge Protection 6 kV peak per E N 61010-1 Ed . 2.0 (2001-02) 2 Fluke Corporation Fluke 1650B Series Multifunction Installation Testers