Ordering Information 291 1 Channel 100 MS/s Arbitrary Waveform Generator and Waveform Manager Plus Software. Fluke 280 and 290 Series Single and Compact Flash Memory Card and USB Card Reader/Writer 292 2 Channel, 100 MS/s Arbitrary Waveform Generator and Waveform Manager Plus Software. Multi-Channel Universal ARB Generators Compact Flash Memory Card and USB Card Reader/Writer 294 4 Channel, 100 MS/s Arbitrary Waveform Generator and Waveform Manager Plus Software. Compact Flash Memory Card and USB Card Reader/Writer 281 1 Channel 40 MS/s Arbitrary Waveform Generator and Waveform Manager Plus Software 282 2 Channel, 40 MS/s Arbitrary Waveform Generator and Waveform Manager Plus Software 284 4 Channel, 40 MS/s Arbitrary Waveform Generator and Waveform Manager Plus Software Additional included accessories (290 Series) IEC Mains Lead RS-232 Lead Manual Additional included accessories (280 Series) IEC Mains Lead RS-232 Lead Manual Options and accessories 19-inch rack mounting kit for one multi-channel generator 19-inch rack mounting kit for one or two single- channel generators 291 Fluke. Keeping your world up and running. Fluke Corporation PO Box 9090, Everett, WA U.S.A. 98206 One, two or four independent Fluke Europe B.V. or inter-linked channels PO Box 1186, 5602 BD Eindhoven, The Netherlands For more information call: 40 MS/s or 100 MS/s, up to In the U.S.A. (800) 443-5853 or 281 Fax (425) 446-5116 1 M words per channel In Europe/M-East/Africa +31 (0) 40 2675 200 or Fax +31 (0) 40 2675 222 In Canada (800)-36-FLUKE or Function generator and pulse Fax (905) 890-6866 From other countries +1 (425) 446-5500 or generator capabilities Fax +1 (425) 446-5116 Web access: Universal waveform generators offering superior performance and excellent value the clock jitter associated with The Fluke 280 Series and DDS arbitrary generators and 290 Series Waveform permits waveform linking, Generators combine a looping and sequencing. true variable clock Waveforms may be defined arbitrary waveform with up to 4096 vertical points Features and from 8 M to 1 M horizontal generator with a high 1, 2 or 4 waveform channels, points (4 K to 64 K points on 40 MS/s or 100 MS/s performance DDS func- independent or linked 280 Series units). one, two or four channels tion generator and pulse 40 MS/s or 100 MS/s 12-bit arbitrary Arbitrary waveforms may be waveform capability using true generator in a single replayed at a specified waveform variable clock architecture have a USB interface. These can Waveform creation instrument. frequency, period or sample clock 64 K or 1 M point waveform memory be used for loading arbitrary rate. An external sample clock and editing per channel wave forms and for remote Wide model range can also be used on 290 Series 16 MHz or 50 MHz function Waveform creation and editing control of all the instru ment units allowing seamless on the generators using direct digital The Fluke 280 Series and features are inc orporated within functions. synthesis (DDS) fly changes to output frequency. 290 Series comprise of six models: the instrument. These include Multiple standard waveforms includ- The 290 series waveform 281 40 MS/s single-channel waveform insert, point edit, Waveform sequencing ing sine, square, triangle, haversine, storage is on removable Compact waveform generator in 3U half line draw, amplitude adjust and ramp, pulse and sin(x)/x The variable clock architec- Pulse generator Flash cards, making waveform rack size case. invert. Pulse train pattern generation for up ture of the 280 and 290 Series management easy and effectively A wide range of standard 282 40 MS/s two-channel to 10 pulses enables waveforms to be unlimited. waveforms are avail able for waveform generator in 3U case. Complex waveform sequencing and sequenc ed. Up to 1024 arbitrary looping capability using up to 1024 insertion within an arbitrary 284 40 MS/s four-channel waveforms may be linked in a Function generator waveform segments waveform. Sections of existing waveform generator in 3U case. sequence (16 waveforms on 280 Each channel can operate as a Wide range sweep, AM, tone arbitrary waveforms can also 291 100 MS/s single-channel Series). Each waveform can have full DDS function generator. High switching, signal summing be inserted. For more sophis- waveform generator in 3U half a loop count of up to 32,768 and quality sine, cosine, haversine, Inter-channel triggering, summing ticated waveform creation and rack size case. and phase control the whole sequence can be run havercosine and square waves editing, Waveform Manager Multiple generators can be easily contin uously or re peated more are available between 1 mHz and 292 100 MS/s two-channel Plus software for the Window s phase locked than a million times. 16 MHz (280 Series) or up to 50 waveform generator in 3U case. operating system is provided. Waveform sequencing External ARB clock input For multi-channel models, MHz (290 Series). Triangle, ramp 294 100 MS/s four-channel Waveforms created on a PC (290 Series only) waveforms on dif ferent channels and sine(x)/x waveforms are waveform generator in 3U case. can be down loaded to the Waveform creation/editing tools built can be daisy chained and available from 0.1 mHz up to On multi-channel units, each instrument via the digital inter- in sophisticated external Windows looped. By summing the channel 500 kHz. based software included channel can be operated fully faces (or memory card where outputs, multiple segments from Built-in trigger generator, gated and independently, or multiple chan- fitted). Pulse generator multiple channels can be used triggered burst modes nels can be linked using simple to create highly complex wave- Each channel can generate not Tone switching facilitates precision Memory card storage or complex relationships. forms. just pulses, but also complex DTMF generation Fluke 290 Series units incorpo- pulse trains. A pattern of up to Unlimited waveform storage using CF A true arbitrary generator rate a CompactFlash memory Wide range sweep memory cards (290 Series only) 10 pulses can be quickly defined, The 280 and 290 Series are card, giving effectively unlim- GPIB (IEEE-488.2), RS-232 and USB All waveforms can be swept with each pulse having its own highly sophisticated 12-bit ited stor age for waveforms and interfaces (280 Series units have over their full frequenc y range amplitude, width and delay. arbitrary waveform generators GPIB and RS-232 only) setups. Waveform data can be at a rate variable between milli- The whole pulse train pattern capable of recreating virtually transferred directly from a PC to seconds and minutes. Sweep can then be replayed at a user any waveform. True variable the memory card using the USB can be linear or logarithmic, defined repetition rate. Where clock architecture is used with card reader/writer supplied. single or continuous. Single variable rise time pulses are clock speeds between 0.1 Hz and sweeps can be triggered from required, the full arbitrary GPIB, RS-232, USB 100 MHz (40 MHz on 280 Series the front panel, the trigger input, function can be used. units). This architecture avoids The 280 and 290 Series or the digital interfaces. Multiple incorporate both RS-232 and channels can be swept simulta- GPIB (IEEE-488) interfaces as neously. standard. 290 Series units also 2 Fluke 280 and 290 Series