700P04 PRESSURE MODULE RANGE 15 PSID/G 100 kPa 1 bar Certifications Conforms to European Standard EN61010-1, EN61326. Limited Warranty 700P2X Series Pressure Modules Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year Instruction Sheet and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Flukes opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of Low operation or handling. Fluke warrants that software will operate substantially in Differential accordance with its functional specifications for 90 days and that it has been properly recorded on nondefective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused High products to enduser customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Flukes warranty obligation is limited, at Flukes option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. Introduction To obtain warranty service, contact your nearest Fluke authorized service center The Fluke 700P2X Series Pressure Modules allow you to or send the product, with a description of the difficulty, postage and insurance measure pressure with the Fluke 700 Series Documenting prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke Process Calibrators. Read this sheet before you use the assumes no risk for damage in transit. Following warranty repair, the product pressure module. This sheet contains specifications and will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that the failure was caused by misuse, alteration, accident or information about how to avoid damaging the pressure abnormal condition of operation or handling, Fluke will provide an estimate of module. See the 700 Series Users Manual for operating repair costs and obtain authorization before commencing the work. instructions. Following repair, the product will be returned to the Buyer transportation prepaid Note and the Buyer will be billed for the repair and return transportation charges (FOB Fluke-701 or Fluke-702 software V1.3 or higher is Shipping Point). required. See specification footnote 1. THIS WARRANTY IS BUYERS SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING The pressure module measures pressure using an internal BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY microprocessor. It receives operating power from and sends OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE digital information to the 700 Series calibrator. LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING Gage pressure modules have one pressure fitting and FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, measure pressure with respect to atmospheric pressure. RELIANCE OR ANY OTHER THEORY. Differential pressure modules have two pressure fittings and Since some countries or states do not allow limitation of the term of an implied measure the difference between the applied pressure on the warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any high fitting versus the low fitting. A differential pressure provision of this Warranty is held invalid or unenforceable by a court of module functions like a gage module when the low fitting is competent jurisdiction, such holding will not affect the validity or enforceability of open. any other provision. In Case of Difficulty Box Contents For service or calibration, call your nearest authorized Fluke Pressure module, strap, 1/4 NPT to 1/4 ISO metric adapters, Service Center. instruction sheet. For application or operation assistance or information on Protecting Yourself from Pressure Releases Fluke products, call: To avoid a violent release of pressure in a pressurized system, shut off the isolation valve and slowly bleed off the USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) pressure before you attach or remove the pressure module Europe: +31 402-678-200 from the pressure line. Japan: +81-3-3434-0181 Singapore: +65-738-5655 Avoiding Mechanical Damage Anywhere in the world: +1-425-446-5500 To avoid damaging the pressure module, never apply more Or, visit Flukes Web site at w ww.fluke.com than 10 ft.-lbs. of torque between the pressure module fittings or between the fittings and the body of the module. Always Fluke Corporation Fluke Europe B.V. apply appropriate torque between the pressure module fitting P.O. Box 9090 P.O. Box 1186 and connecting fittings or adapters. Figure 1 shows the Everett, WA 98206-9090 5602 B.D. Eindhoven correct way and incorrect ways to use a wrench when USA The Netherlands applying torque to the pressure module fitting. PN 601093 (English) August 1995 Rev.2, 11/01 1995-2001 Fluke Corporation. All rights reserved. Printed in USAPRESSURE MODULE 700P04 RANGE 15 PSID/G 100 kPa 1 bar Pressure Calibration Kit The Fluke-700PCK Pressure Calibration Kit makes it possible to calibrate pressure modules at ambient temperature with a precision pressure calibrator better than the module specification. A 386 or better PC and Windows 3.1 or later are required. The kit is an optional accessory available from your distributor or Fluke. Performance Test If you need to check that the pressure module meets its accuracy specification, use a dead weight tester or suitable pressure calibrator. The accuracy of the dead weight tester or pressure calibrator should be significantly better than the Figure 1. 700P2X Series pressure specification. Proceed as follows to verify that a pressure module is operating within Avoiding Overpressure Damage specification: Applying pressure in excess of the BURST PRESSURE 1. Read the pressure value with no externally applied specified on the pressure module can destroy the pressure pressure to make sure the 0% of scale is correct. When module. Burst pressure is 3X full scale. reading the pressure, press the ZERO key to remove any zero offset. Avoiding Corrosion Damage Note To avoid damaging the pressure module from corrosion, use The pressure ZERO function is available on Fluke- it only with specified media as shown below: 701 and Fluke-702 calibrators with V1.3 or higher software. Contact your Fluke Service Center for High: any medium that is compatible with type 316 upgrade of earlier calibrators. stainless steel. 2. Connect the pressure module to a dead weight tester. Low: dry, noncorrosive gasses only. 3. Set the dead weight tester to 20% of the pressure modules full scale value. Recommended Measurement Technique For best results, it is recommended that the module be 4. Make sure the reading agrees with the dead weight pressurized to full scale and then vented to zero pressure tester value within the specification in Table 1. (atmosphere) prior to zeroing and making measurements. 5. Set the dead weight tester to 40, 60, 80, and 100% of Note full scale and compare the respective readings. Low range pressure modules may be sensitive to 6. If temperature sensitivity is of concern, repeat steps 1 gravity. For best results, pressure modules 30 psi through 5 at various controlled temperatures. and below should be held at the same physical orientation from the time they are zeroed until the measurement is complete. 1 Table 1. Specifications (% of full span) 2 Model Range Gage or Isolated or Reference Stability Temp Total 3 Differential Nonisolated Uncertainty (1 Year) (0 to 50 C) Uncertainty (23 3 C) Fluke-700P22 0 to 1.0000 psi Differential Isolated 0.100% 0.020% 0.030% 0.150% 0 to 6.8900 kPa 0 to 6.89 E-2 bar Fluke-700P23 0 to 5.0000 psi Differential Isolated 0.025% 0.010% 0.015% 0.050% 0 to 34.000 kPa 0 to 0.3400 bar Fluke-700P24 0 to 15.000 psi Differential Isolated 0.025% 0.010% 0.015% 0.050% 0 to 100.00 kPa 0 to 1.0000 bar 1. Use of pressure zero function is required to achieve these specifications. Contact your Fluke Service Center for upgrade of your Fluke 701 or Fluke 702 V1.0, V1.1, or V1.2 Calibrator. 2 2. Available pressure units (inHg, kg/cm , mmH 0) are determined by the calibrator being used. 2 3. Accuracy specifications apply for 1 year for 0 to 100% of full span from 0 to 50 C. Typical uncertainty is 1% of full span from -10 C to 0 C. 4. Maximum non-destructive pressure: 3X maximum rated pressure, including common mode pressure. 5. Maximum common mode pressure: 3X maximum rated pressure. 6. Specifications reflect a confidence interval of 95%.