Product Compliance Markings P ( II 1 G Eex ia IIC T4 0344 700PEx Series Pressure Modules ) I.S. Class I Div. 1 Groups A-D T4 221839 AEx ia IIC T4 Instruction Sheet Ta = 0 C + 50 C Introduction Ex Cerification by Mensor Corporation, San Marcos, TX USA The Fluke 700PEx Series Pressure Modules allow you to measure pressure with Fluke intrinsically safe calibrators EMC: Complies with EN61326, Criteria C. such as the 718Ex. Read this sheet before using the pressure modules. This instruction sheet contains Limited Warranty specifications and information about how to avoid damaging Each Fluke product is warranted to be free from defects in material and the pressure modules and describes how to safely use them workmanship under normal use and service. The warranty period is one year in hazardous locations. Refer to your calibrators Users and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This warranty extends only to the original buyer or end Manual for complete operating instructions. user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries or to any product which, in Flukes opinion, has been The pressure modules measure pressure using an internal misused, altered, neglected or damaged by accident or abnormal conditions of microprocessor. They receive operating power from and operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been send digital information to the intrinsically safe calibrators. properly recorded on nondefective media. Fluke does not warrant that software will be error free or operate without interruption. Gage pressure modules have one pressure fitting and Fluke authorized resellers shall extend this warranty on new and unused measure pressure with respect to atmospheric pressure. products to enduser customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is Differential pressure modules have two pressure fittings purchased through a Fluke authorized sales outlet or Buyer has paid the and measure the difference between the applied applicable international price. Fluke reserves the right to invoice Buyer for pressure on the high fitting versus the low fitting. A importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. differential pressure module functions like a gage Flukes warranty obligation is limited, at Flukes option, to refund of the purchase module when the low fitting is open. price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. Absolute pressure modules measure relative to a To obtain warranty service, contact your nearest Fluke authorized service center vacuum. or send the product, with a description of the difficulty, postage and insurance prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke In Case of Difficulty assumes no risk for damage in transit. Following warranty repair, the product For service or calibration, call your nearest authorized Fluke will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke Service Center. determines that the failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will provide an estimate of For application or operation assistance or information on repair costs and obtain authorization before commencing the work. Fluke products, call: Following repair, the product will be returned to the Buyer transportation prepaid USA: 1-888-99-FLUKE (1-888-993-5853) and the Buyer will be billed for the repair and return transportation charges (FOB Canada: 1-800-36-FLUKE (1-800-363-5853) Shipping Point). Europe: +31 402-675-200 THIS WARRANTY IS BUYERS SOLE AND EXCLUSIVE REMEDY AND IS IN Japan: +81-3-3434-0181 LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING Singapore: +65-738-5655 BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE Anywhere in the world: +1-425-446-5500 LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL Or, visit Fluke s Web site at www.fluke.com. DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, To register your product, visit register.fluke.com RELIANCE OR ANY OTHER THEORY. Fluke Corporation Fluke Europe B.V. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the P.O. Box 9090 P.O. Box 1186 limitations and exclusions of this warranty may not apply to every buyer. If any Everett, WA 98206-9090 5602 B.D. Eindhoven provision of this Warranty is held invalid or unenforceable by a court of USA The Netherlands competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Box Contents Each pressure module comes with an installed strap and instruction sheet. All pressure modules, with the exception of the 700P29Ex, come with 1/4 NPT to 1/4 ISO metric adapters. PN 2106534 (English) May 2004 2004 Fluke Corporation. All rights reserved. Printed in USA Safety Information Faults and Damage In this instruction sheet a Warning identifies conditions and If there is any reason to suspect that the safe operation of actions that pose hazards to the user. A Caution identifies the pressure module has been affected, it must be conditions and actions that may damage the pressure immediately withdrawn from use and precautionary module or equipment under test. International symbols used measures must be taken to prevent any further use of the in this instruction sheet are identified later in the Symbols pressure module in an Ex hazardous area. section. Read the entire instruction sheet and the 700PEx CCD (Concept Control Drawing) before using the pressure XW Warning module. The safety features and integrity of the pressure module may be compromised by any of the following: In case of doubt (due to translation and/or printing errors) refer to the original English instruction sheet. External damage to the housing Internal damage to the pressure module XW Warning Exposure to pressure loads in excess of the To avoid electric shock, injury, or damage to the maximum rated pressure pressure module: Incorrect storage of the unit Use the pressure module only as described in this instruction sheet and the Fluke Damage sustained in transit 700PEx CCD (Concept Control Drawing) Correct certification is illegible otherwise the protection provided by the pressure module may be impaired. Functioning errors occur Inspect the pressure module before use. Do Permitted limitations are exceeded not use it if it appears damaged. Functioning errors or obvious measurement Check the cable for damaged insulation. Do inaccuracies occur which prevent further not use the pressure module if the cable measurement by the pressure module appears damaged. Safety Regulations Never use the pressure module with the case open. Opening the case invalidates Ex The use of the 700PEx pressure modules meets the Approval. requirements of the regulations providing that the user observes and applies the requirements as laid down in the This equipment is specified for use in regulations and that incorrect use of the unit is avoided. Use measurement category I (CAT I) pollution must be restricted to the specified application parameters. degree 2 environments and should not be used in CAT II, CAT III, or CAT IV Protecting Yourself from Pressure Releases environments. Voltage transients should not exceed 300 volts for the CAT I applications XW Warning where this product is used. Measurement To avoid injury due to the release of high transients are defined in IEC1010-1 as 2 s pressure, use only adapters and fittings rise time with a 50 s duration at 50 % of the rated to withstand the appropriate pressure. maximum amplitude height. Ensure that all adapters and fittings are Measurement Category I (CAT I) is defined securely connected. for measurements performed on circuits not To avoid a violent release of pressure in a directly connected to the mains. pressurized system, slowly bleed off the Symbols pressure before you attach or remove the pressure module from the pressure line. The following symbols are used on the pressure module or in this instruction sheet. When measuring the pressure of potentially hazardous media, care must be taken to Table 1. Symbols minimize the possibility of leakage. Confirm that all pressure connections are properly Conforms to relevant European directives. P sealed. Conforms to relevant Canadian and US standards. Avoiding Mechanical Damage ) To avoid damaging the pressure modules, never apply more than 10 ft.-lbf. of torque between the module fittings or Risk of danger. Important information. See Manual. W between the fittings and the body of the module. Figure 1 shows the correct way and incorrect ways to use a wrench Certified as meeting instrinsically safe standards of when applying torque to the pressure module fitting. ( European approval agencies. Pressure. f