Certifications P Conforms to European Standard EN61010-1, EN61326. Limited Warranty 700P29, 700P30, 700P31 Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are Pressure Modules warranted for 90 days. This warranty extends only to the original buyer or end user customer of a Fluke authorized reseller, and does not apply to fuses, Instruction Sheet disposable batteries or to any product which, in Flukes opinion, has been misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on nondefective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to enduser customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Introduction Flukes warranty obligation is limited, at Flukes option, to refund of the purchase Fluke Models 700P29, 700P30, and 700P31 Pressure price, free of charge repair, or replacement of a defective product which is Modules allow you to measure high pressure with the Fluke returned to a Fluke authorized service center within the warranty period. 700 Series Documenting Process Calibrators. Read this To obtain warranty service, contact your nearest Fluke authorized service center sheet before you use the pressure module. This sheet or send the product, with a description of the difficulty, postage and insurance contains specifications and information about how to avoid prepaid (FOB Destination), to the nearest Fluke authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the product personal injury and damage to the pressure module. This will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke instruction sheet assumes that you know how to use the 700 determines that the failure was caused by misuse, alteration, accident or Series Documenting Process Calibrator. (Refer to the Users abnormal condition of operation or handling, Fluke will provide an estimate of Manual if necessary.) repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid Note and the Buyer will be billed for the repair and return transportation charges (FOB If you are using a Fluke Model 701 or 702 calibrator, Shipping Point). it must have software V1.3 or later to achieve the THIS WARRANTY IS BUYERS SOLE AND EXCLUSIVE REMEDY AND IS IN specifications in this sheet. See Specifications LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING note 1. BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE The pressure module measures pressure using an internal LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL microprocessor. It receives operating power from and sends DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, digital information to the 700 Series calibrator. RELIANCE OR ANY OTHER THEORY. Box Contents Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the Pressure module, strap, and instruction sheet. limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of Caution competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Only use with Group 2 Fluids compatible with Hastelloy C276. In Case of Difficulty For service or calibration, call your nearest authorized Fluke W WARNING Service Center. To avoid injury due to the release of high pressure fluid, use only adapters and fittings For application or operation assistance or information on rated to withstand the appropriate pressure. Fluke products, call: Ensure that all adapters and fittings are securely USA: 1-888-99-FLUKE (1-888-993-5853) connected. Canada: 1-800-36-FLUKE (1-800-363-5853) W WARNING Europe: +31 402-678-200 Japan: +81-3-3434-0181 To avoid a violent release of pressure in a Singapore: +65-738-5655 pressurized system, shut off the isolation valve Anywhere in the world: +1-425-446-5500 and slowly bleed off the pressure before you attach or remove the pressure module from the Or, visit Flukes Web site at www.fluk e.com pressure line. Fluke Corporation Fluke Europe B.V. P.O. Box 9090 P.O. Box 1186 Everett, WA 98206-9090 5602 B.D. Eindhoven USA The Netherlands PN 602083 (English) August 1996 Rev.3, 10/02 1995-2002 Fluke Corporation. All rights reserved. Printed in USARANGE 100 kPa 1 bar Avoiding Mechanical Damage Pressure Calibration Kit To avoid damaging the pressure module, never apply more The Fluke 700PCK Pressure Calibration Kit makes it possible than 10 ft.-lb. of torque between the pressure module fitting to calibrate pressure modules at ambient temperature with a and the body of the module. Always apply appropriate torque precision pressure calibrator or dead weight tester. The between the pressure module fitting and connecting fittings accuracy of the dead weight tester or pressure calibrator or adapters. Figure 1 shows the correct and incorrect ways must be significantly better than the pressure module to use a wrench when applying torque to the pressure specification. A 386 or better PC and Windows 3.1 or later module fitting. are required. The kit is an optional accessory available from your distributor or Fluke. Performance Test If you need to check that the pressure module meets its accuracy specification, use a dead weight tester or suitable pressure calibrator. The accuracy of the dead weight tester or pressure calibrator should be significantly better than the pressure module specification. Proceed as follows to verify that a pressure module is operating within specification: 1. Read the pressure value with no externally applied pressure to make sure the 0% of scale is correct. When reading the pressure with a 700 Series calibrator, press Figure 1. the CLEAR (ZERO) key to remove any zero offset. Avoiding Overpressure Damage Note Applying pressure in excess of the BURST PRESSURE The pressure zero function is available on Fluke 701 specified on the pressure module can destroy the pressure and 702 calibrators with V1.3 or later software. module. Burst pressure is 2X full scale for the 700P29 and Contact a Fluke Service Center to upgrade your 700P30, and 1.5X full scale for the 700P31. V1.0, V1.1, or V1.2 calibrator. Avoiding Corrosion Damage 2. Connect the pressure module to a dead weight tester. To avoid damaging the pressure module from corrosion, use 3. Set the dead weight tester to 20% of the pressure it only with a medium that is compatible with Hastelloy C276. modules full scale value. Recommended Measurement Technique 4. Make sure the reading agrees with the dead weight For best results, it is recommended that the module be tester value within the specification in Table 1. pressurized to full scale and then vented to zero pressure 5. Set the dead weight tester to 40, 60, 80, and 100% of (atmosphere) prior to zeroing and making measurements full scale and compare the respective readings. with the 700 Series calibrator. 6. If temperature sensitivity is of concern, repeat steps 1 through 5 at various controlled temperatures. 1 Table 1. Specifications (% of full span) 4 2 3 Model Range Reference Uncertainty Stability Temp Total Uncertainty (23 3 C) (1 Year) (0 to 50 C) 700P29 0 to 3000 psi 0.050% 0.010% 0.020% 0.080% 0 to 20680 kPa 0 to 207 bar 700P30 0 to 5000 psi 0.050% 0.010% 0.020% 0.080% 0 to 34500 kPa 0 to 345 bar 700P31 0 to 10000 psi 0.050% 0.010% 0.020% 0.080% 0 to 69000 kPa 0 to 690 bar 1. Use of pressure zero function is required to achieve these specifications. Contact a Fluke Service Center to upgrade your Fluke 701 or 702 V1.0, V1.1, or V1.2 Calibrator. 2 2. Available pressure units (psi, kPa, bar, inHg, mmHg, inH 0, ftH 0, kg/cm , mmH 0) are determined by the calibrator being used. 2 2 2 3. Accuracy specifications apply for 1 year for 0 to 100% of full span from 0 to 50 C. Typical uncertainty is 1% of full span from -10 C to 0 C. 4. Maximum non-destructive pressure: 2X maximum rated pressure for P29 and P30, 1.5X for P31. 5. Specifications reflect a confidence interval of 95%.