M C E E T R S T Y I F S I E T D N E T M O E ScopeMeter 190C/190B Series and ScopeMeter 120 Series Technical Data ScopeMeter 190C and 190B Up to 2.5 GS/s real time Automatic capture and replay of Series: Speed, performance sampling per input 100 screens and analysis power High Waveform Resolution of 27,500 points and more per 3000 datapoints per channel input record length using For demanding applications, the ScopeRecord mode ScopeMeter 190C and 190B Series Frequency Spectrum using FFT high-performance oscilloscopes analysis (190C) 1,000 V CAT II and 600 V CAT offer specifications usually found on III safety certified Connect-and-View automatic top-end bench instruments. With triggering, a full range of man- Up to 1,000 V independently up to 200 MHz bandwidth, ual trigger modes plus external floating isolated inputs 2.5 GS/s real time sampling and a triggering Four hours rechargeable deep memory of 27,500 points per Digital Persistence for analyzing NiMH battery pack R input theyre ideal for engineers complex, dynamic signals like who need the full capabilities of a ScopeMeter 120 Series: on an analog oscilloscope (190C) high-performance scope in a hand- Three-in-one simplicity held, battery powered instrument. Fast display update rate for Dual input - 200, 100 or seeing dynamic behavior The compact ScopeMeter 120 Series 60 MHz bandwidth instantaneously is the rugged solution for industrial troubleshooting and installation applications. Its a truly integrated test tool, with oscilloscope, multi- meter and paperless recorder in Now expanded with 3K memory and one affordable, easy-to-use instru- FFT Frequency Spectrum Analysis ment. Find fast answers to problems in machinery, instrumentation, control and power systems. A dual input 40 MHz or 20 MHz digital oscilloscope Two 5,000 counts true-rms digital multimeters Cursor measurements (Fluke 124) A dual input TrendPlot recorder Connect-and-View trigger simplicity for hands-off operation Shielded test leads for oscillo- scope, resistance, continuity and capacitance measurements Full bandwidth, VPS40 10:1 40 MHz probe included standard with Fluke 124 Up to seven hours battery operation 600 V CAT III safety certified Optically isolated RS-232 interface Rugged, compact case G M A E N E A T M I S Y T O I L 9 A 0 0 U 1 QTechnical Specifications 190C and 190B Series Connect-and-View: Advanced automatic triggering Oscilloscope Mode that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and Vertical Deflection amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and Fluke 199C Fluke 196C Fluke 199B Fluke 196B Fluke 192B control signals. Bandwidth 200 MHz 100 MHz 60 MHz Video triggering: NTSC, PAL, PAL+, SECAM. Includes Rise time 1.7 ns 3.5 ns 5.8 ns field 1, field 2 and line select. Pulse width triggering: Pulse width qualified by time. Bandwidth limiter: User selectable: 10 kHz, 20 MHz Allows for triggering <t, >t, =t, t, where t is selec- or off table in minimal steps of 0.01 div. or 50 nsec. Number of inputs: 2 plus external trigger. All inputs Time delay: One full screen of pre-trigger view or up isolated from each other and ground. to 100 screens (= 1200 divisions) of post-trigger delay Input coupling: AC or DC, with ground level indicator Dual slope triggering: Both rising and falling transi- Input sensitivity: 2 mV/div to 100 V/div (Fluke 190C tions, when crossing the trigger level, initiate an Series) 5 mV/div to 100 V/div (Fluke 190B Series) acquisition (190C only) Normal/Invert: On both input channels switched N-cycle triggering: Triggers on N-th occurrence of a separately trigger event N to be set in the range 2 to 99 (190C Variable attenuator: Variable gain on input channel A only) Input voltage: 1000 V CAT II, 600 V CAT III rated - See general specifications for further details. Automatic Capture of 100 Screens Vertical resolution: 8 bit The instrument ALWAYS memorizes the last 100 Accuracy: (1.5% of reading + 0.04 x range/div) screens (no user setup required). When an anomaly Input impedance: 1 M 1% // 15 pF 2 pF occurs on screen, the REPLAY button can be pressed to review the full screen sequence over Horizontal and over. Instrument can be set up for triggering on glitches Fluke 199C Fluke 196C or intermittent anomalies and will operate in Fluke 199B Fluke 196B Fluke 192B baby-sit mode and will capture 100 events. Maximum 2.5 GS/s 1 GS/s 500 MS/s real-time Alternatively, the 199C and 196C can be set up in sample rate waveform compare mode to store only matching Number of 2 2 2 (Pass) or only non-matching (Fail) acquired wave- digitizers forms in the replay memory bank for further analysis. Time base 5 ns/div 10 ns/div Replay: Manual or continuous replay. Displays the range to 5 s/div to 5 s/div captured 100 screens as a live animation or under manual control. Each screen has date- and time-stamp. Maximum record length: 3000 points per input in Replay storage: Up to 2 sets of 100 screens each Scope-mode 27,500 points per input in can be saved for later recall and analysis ScopeRecord roll mode (5 ms/div to 2 min/div) Accuracy: (0.01 % of reading + 1 pixel) FFT - Frequency Spectrum Analysis Glitch capture: 50 nsec (at 5 sec/div to 1 min/div) (190C only) 250 nsec (at 2 min/div) Shows frequency content of oscilloscope waveform using Fast Fourier Transform Display and Acquisition Window: Automatic, Hamming, Hanning or None Automatic window: Digitally re-samples acquired Fluke 190C Fluke 190B waveform to get optimum frequency resolution in FFT Display 144 mm 144 mm Full Color LCD Monochrome LCD resultant Display modes Input A, Input B, dual, average, Replay Vertical scale: Linear / Logarithmic, in volts Persistence Digital Persistence: Persistence Frequency axis: Logarithmic frequency range auto- modes short/medium/long/infinite on / off matically set as function of timebase range of oscillo- scope Visible screen width: 12 divisions Waveform mathematics: A + B, A - B, A * B, all Waveform Compare and Pass/Fail Testing with user selectable scaling of resultant A versus B Waveform compare: Provides storage and display of a (X - Y-mode) Frequency Spectrum using FFT analysis reference waveform for visual comparison with newly (190C only) acquired waveforms. Reference is derived from an Acquisition modes: Normal, auto, single shot, acquired waveform and can be modified in the ScopeRecord roll, glitch capture, waveform ScopeMeter or externally using FlukeView Software. compare, waveform compare with automatic Pass/Fail Testing (199C, 196C): In waveform compare Pass / Fail testing (in 199C and 196C only) mode, the Color Scopemeter can be set up to store only matching (Pass) or only non-matching (Fail) Trigger and Delay acquired waveforms in the replay memory bank for Source: Input A, input B, external trigger input. further analysis. All input references isolated from each other and from ground Modes: Automatic Connect-and-View, free run, single shot, edge, delay, video, video line, selectable pulsewidth, dual slope (190C only), N-cycle (190C only) 2 Fluke Corporation ScopeMeter 190C/190B Series and ScopeMeter 120 Series