6000 Series PAT testers Portable appliance testing The low weight, small size, one-touch solution The Fluke 6200 and 6500 PAT testers verify Fluke simplies portable the electrical safety and operation of appliance testing portable appliances in accordance with Compact and lightweight relevant guidelines and regulations. Efcient to work with and easy to carry With powerful auto test capabilities and around and has extra space in the hard simplied controls they increase the case for accessories. number of tests you can perform per day One touch simplicity without compromizing results. Pre-set and user-denable test routines are initiated from a single button to A choice of automatic and manual speed up test procedures and save you time on site. PAT testers A better way of working Both models perform all the tests required Rapid data entry via a QWERTY keyboard for class I and class II appliances. (or optional Fluke barcode scanner) and For manual testing and low volume fast data transfer from the main memory applications, choose the cost-effective 6200 or the Compact Flash memory card (6500). PAT model. If you need a more powerful instrument to test large numbers of appliances, the 6500 is the right choice. 6200 6500 As 6200 but also with: Dedicated key for each test for one-touch Integral QWERTY keyboard for rapid testing data entry Pre-set pass/fail levels to save time Additional Compact Flash memory card Large backlit display for easy reading for back-up data storage and transfer to PC Pre-set, auto-test sequences for user convenience Features Measurement functions 6200 6500 L N Mains Volts Outside Limits Indicators Null out facility for earth bond lead Protective Earth Resistance PE (200mA) Protective Earth Resistance PE (25A) Insulation 500V dc Protective Earth Conductor Current Touch Current Substitute Leakage Current Appliance Power kVA Appliance Load Current Seven Segment Custom LCD Graphical LCD Back Light Compact Flash Card receptacle Serial Port - Printing / Downloading External printer output Front Panel QWERTY Key pad IEC Lead Test Included Accessories Auto-testing art.nummer Test lead Pass / Fail Level Programmable Indicators art.nummer Test probe Data Storage art.nummer Crocodile clip Limited Data Storage art.nummer Mains cord Polarity Checks Graphical Help Menu On Line Ordering Information Programme Mode Real time clock Fluke 6200-05 PAT tester Fluke 6500-05 PAT tester Front panel results management 230V Schuko Test socket / 230V Mains Schuko input power plug 6000 Series PAT testers Specications The accuracy specication for the display range is dened as (%reading + digit counts) at 23 C 5 C, 75 % RH. Between 0 C and 18 C and between 28 C and 40 C, accuracy specications may degrade by 0.1 x (accuracy specication) per C. The measurement range meets the service operating errors specied in EN61557-1: 1997, EN61557-2: 1997 , EN61557-4: 1997. Power-on Test Touch Current Test The test indicates reversed L-N, missing PE, and Display Range 0 to 1.99 mA ac Separate hard case measures the mains voltage and frequency. Accuracy (4% + 2 counts) The compact Fluke PAT testers are supplied with Display Range 90 V to 264 V Resolution 0.01 mA a hard carrying case that not only offers Accuracy at 50 Hz ( 2% + 3 counts) Internal Resistance (via probe) 2 k protection during transit but also includes extra Resolution 0.1 V (1V - model 6200) Measuring method Probe storage space for accessories and other tools. Input Impedance > 1 M // 2.2 F The appliance under test is energized at mains potential. Theyre extremely light, weighing approximately Maximum Input Mains Voltage 300 V 3 kg (without case) and have integral carrying Substitute Leakage Current Test handles for extra convenience. Earth Bond Test (Rpe) Display Range 0 to 19.99 mA ac Display Range 0 to 19.99 Accuracy (2.5% + 3 counts) Accuracy ( 2.5% + 2 counts) Resolution 0.01 mA (after Bond Test zeroing) Test Voltage 35 V ac 20% Resolution 0.01 Test Current 200 mA ac -0% +40% into Load/ Leakage Test: Load Current 1.99 25 A ac 20 % into 25 Display Range 0 to 13 A m at 230 V Accuracy (4% + 2 counts) Open Circuit Voltage > 4 V ac, < 24 Vac Resolution 0.1 A Bond Test Zeroing can subtract up to 1.99 The appliance under test is energized at mains potential. Insulation Test (Riso) Load/Leakage Test: Load Power Display Range 0 to 299 M Display Range 0 to 999 VA Accuracy (5% + 2 counts) from 0.1 1.0 kVA to 3.2 kVA to 300 M Accuracy (5% + 3 counts) Resolution 0.01 M (0 to 19.99 M ) Resolution 1 VA (0 to 999 VA) 0.1 M (20 to 199.9 M ) Special PAT Kit 0.1 kVA (1.0 kVA to 3.2 kVA) 1 M (200 to 299M ) If you need a complete PAT tester solution, a The appliance under test is energized at mains potential. Test Voltage 500 V dc 0 % +10 % at 500 k load purpose made kit is available. Load/Leakage Test: Leakage Current Test Current >1 mA at 500 k load, Fluke-6500/NL Kit Contains: < 15 mA at 0 Display Range 0 to 19.99 mA 6500-05, Mainframe Auto discharge time < 0.5 s for 1 F Accuracy (4% + 2 counts) Max. Capacitive Load operational up to 1 F EXTL 100-02, Extension lead test adaptor Resolution 0.01 mA The appliance under test is energized at mains potential. SP Scan 15, Barcode scanner Fluke DMS Software PELV Test Pass 560-05, Appliance pass labels Accuracy at 50 Hz ( 2% + 3 counts) APP 1000, Barcode appliance number labels Overload protection 300 Vrms Warning threshold 25 Vrms Display Screens Size (HxWxD): 200 mm x 275 mm x 100 mm Weight: 3 kg Two Years Warranty Substitute Leakage Current Test Earth Bond Test (RPE) Recommended Accessories Insulation Test (RISO) Touch Current Test Fluke DMS Software SP1000-02 SP-SCAN-15 EXTL100-02 PASS labels (only Fluke 6500)