TECHNICAL DATA TiS75, TiS65, TiS60, TiS55, TiS50, TiS45, TiS40, TiS20 and TiS10 Infrared Cameras The Fluke Performance Series Built with Fluke Connect compatible Rugged. Accurate. Built to perform. Save time - wirelessly sync images directly from your camera to the Fluke Connect system, and attach to an asset record or work order. Having access to maintenance records simultaneously at the inspection site and from the office or an off-site location enables faster decision making and real time collaboration between team members Get the context of the visual and infrared details all in one precisely blended or picture-in-picture image with IR-Fusion technology Get precisely focused images from as close as 15 cm (6 in) with manual focus, or choose fixed focus for faster images without the need to focus from 45 cm (1.5 ft) and beyond Monitor your battery charge and avoid an unexpected loss of power with the smart battery with LED charge indicator Get easy access to saved images with a removable SD card Digitally document critical information such as the location of the equipment or the motor nameplate with the infrared image using IR-PhotoNotes or voice annotation* GOOD IMAGE QUALITY WITH UP TO 320 X 240 RESOLUTION RESOLUTION FIELD OF VIEW TiS75 35.7 H x 26.8 V 320 x 240 See the problem and location in one image with IR-Fusion technology. D:S 504:1 TiS65/60 260 x 195 D:S 409:1 TiS55/50 220 x 165 D:S 346:1 TiS45/40 160 x 120 D:S 252:1 Full infrared 50 % blending, picture-in- 50 % blending TiS20 picture mode 120 x 90 D:S 189:1 *Varies by model TiS10 80 x 60 D:S 126:1 *Varies by modelDetailed specifications TiS75 TiS65 TiS60 TiS55 TiS50 TiS45 TiS40 TiS20 TiS10 Key features IFOV (spatial resolution) 2.0 mRad 2.4 mRad 2.8 mRad 3.9 mRad 5.2 mRad 7.8 mRad 320 x 240 120 x 90 80 x 60 Detector resolution 260 x 195 (50,700 pixels) 220 x 165 (36,300 pixels) 160 x 120 (19,200 pixels) (76,800 pixels) (10,800 pixels) (4,800 pixels) Field of view 35.7 H x 26.8 V Distance to spot 504:1 409:1 346:1 252:1 189:1 126:1 Fixed focus, Manual focus, Fixed focus, Manual focus, Manual focus, minimum focus minimum minimum minimum minimum Fixed focus, minimum focus distance Focus system distance 15 cm (~6 in) focus distance focus distance focus distance focus distance 45 cm (~18 in) 45 cm (~18 in) 15 cm (~6 in) 45 cm (~18 in) 15 cm (~6 in) Wireless connectivity Yes, to PC, iPhone and iPad (iOS 4s and later), Android 4.3 and up, and WiFi to LAN (where available) Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app compatible Fluke Connect app for saving and sharing Fluke Connect Assets Yes*, assign images to assets and create work orders. Easily compare measurement typeswhether mechanical, optional software electrical or infrared imagesin one location Yes*, connect your camera to your buildings WiFi network, and images taken automatically upload to the Fluke Connect Instant Upload Fluke Connect system for viewing on your smartphone or PC Yes*, connects wirelessly to select Fluke Connect enabled tools and displays measurements on camera screen. Fluke Connect tool compatible Five simultaneous connections supported IR-Fusion technology Yes, adds the context of the visible details to your infrared image 100 %, 100 % IR and 50 % IR and full visible full visible on camera AutoBlend mode 100 %, 75 %, 50 %, 25 % IR plus full visible on camera continuously variable in software on camera continuously continuously variable in variable in software software Not available on camera con- Picture-In-Picture (PIP) 100 %, 75 %, 50 %, 25 % IR continuously variable in software tinuously variable in software Ruggedized display 3.5 inch (landscape) 320 x 240 LCD Rugged, ergonomic design for Yes one-handed use 0.10 C at 0.15 C at 0.09 C at 30 C target temp 30 C target 30 C target Thermal sensitivity (NETD) 0.08 C at 30 C target temp (80 mK) (90 mK) temp temp (100 mK) (150 mK) Level and span Smooth auto and manual scaling Fast auto toggle between manual Yes and auto modes Fast auto-rescale in manual Yes mode Minimum span (in manual mode) 2.5 C (4.5 F) Minimum span (in auto mode) 5 C (9.0 F) Built-in digital camera (visible light) 5MP 30 Hz or 9 Hz 30 Hz or 9 Hz Frame rate 30 Hz or 9 Hz versions 9 Hz 9 Hz 9 Hz versions versions Laser pointer Yes Data storage and image capture Internal 4GB memory Extensive memory options Internal 4GB memory and 4GB micro SD card (includes slot for optional micro SD card) Image capture, review, save One-handed image capture, review, and save capability mechanism Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) Image file formats No analysis software required for non-radiometric (.bmp, .jpg) files Memory review Dedicated memory view button for quick access to stored images thumbnail and full screen review Software SmartView full analysis and reporting software and Fluke Connect system* Export file formats with SmartView Bitmap (.bmp), GIF, JPEG, PNG, TIFF software 60 seconds maximum recording time per image reviewable playback on camera Voice annotation Bluetooth headset required (sold separately) IR-PhotoNotes Yes (3 images) Yes (1 image) Video recording Standard and radiometric Non-radiometric (MPEG - encoded .avi) and Video file formats fully radiometric (.is3) Yes, see the live stream of the camera display on your PC or smartphone. Via USB, WiFi Streaming video (remote display) hotspot, or WiFi network to SmartView soft- ware on a PC or via WiFi hotspot to the Fluke Connect app on a smartphone Auto capture Yes (temperature and interval) *Fluke Connect system is not available in all countries. Please check availability with your authorized Fluke distributor. 2 Fluke Corporation TiS75, TiS65/60, TiS55/50, TiS45/40, TiS20, TiS10 Infrared Cameras