M C E E T R S T Y I F S I E T D N E T M O E ScopeMeter 190 Series 190 Series II, 190C Series, and 190C Series with Bus Health Technical Data A new generation of ScopeMeter Series II 190-104 and 190-204: ScopeMeter The first high-performance four-channel The 190 Series II include these new capabilities: scopes built for harsh industrial environments 4 independent floating isolated Introducing the first high-performance portable oscilloscopes inputs, up to 1000 V with four independent isolated input channels, an IP 51 dust- High-speed sampling: Up to and drip-proof rating, and a CAT III 1000 V / CAT IV 600 V safety 2.5 GS/sec rating. Choose 200 MHz or 100 MHz bandwidth models. Now, Deep memory: 10,000 points per plant maintenance engineers and technicians can take a four- trace waveform capture channel scope into the harsh world of industrial electronics. CAT III 1000 V/CAT IV 600 V rated for safety in high voltage environments Up to 7 hours of battery operation, standard Isolated USB host port for direct data storage to a USB memory device USB device port for easy PC communication Easy access battery door for quick battery swaps in the field Compact and only 2.2 kg (4.8 lb) Security slot: lock down oscillo- scope with Kensington lock while unattended ScopeMeter 190C Series and 190 Series II Rugged performance, speed and ease of use no matter which model you use All 190 Series models offer: IP 51 rating, dust- and drip-proof Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals Frequency Spectrum using FFT-analysis Automatic capture and REPLAY of 100 screens Models 190-204, 199C, and 225 C shown here Deep waveform memory storage (up to 10,000 points per input channel) 30,000 points or more per input channel using ScopeRecord roll mode Paperless recorder with deep memory for long-term automatic measure- ments Oscilloscope Modes G M A E N E A T M I S Y T O I L 9 A 0 0 U 1 QOscilloscope modes 190C Series 190 Series II 199C, 225C 196C, 215C 192C 190-204 190-104 Vertical deflection Number of channels 2 2 2 4 4 Bandwidth 200 MHz 100 MHz 60 MHz 200 MHz 100 MHz Rise time 1.7 ns 3.5 ns 5.8 ns 1.7 ns 3.5 ns Number of inputs 2 inputs plus external trigger 4 input channels Channel architecture All inputs fully insulated from each other and from ground. Inputs may be activated in any combination. Input coupling AC or DC, with ground level indicator Input sensitivity 2 mV/div to 100 V/div Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth Normal/invert On each input channel, switched separately Variable attenuator Variable Gain on input channel A Variable Gain on each input channel Input voltage CAT II 1000 V, CAT III 600 V rated see General Specifications for CAT III 1000 V, CAT IV 600 V rated see further details General Specifications for further details Vertical resolution 8 bit Accuracy (1.5 % of reading + 0.04 x range/div) 5 mV/div to 100 V/div (2.1 % of reading + 0.04 x range/div) 5 mV/div to 100 V/div. Input impedance 1 M 1 % // 15 pF 2 pF 1 M 1 % // 14 pF 2 pF Horizontal Maximum real-time 2.5 GS/s (2 ch) 1 GS/s (2 ch) 500 MS/s (2 ch) 2.5 GS/s (2 ch) 1.25 GS/s for each sample rate 1.25 GS/s (4 ch) channel Record length Up to 3000 samples per channel Up to 10,000 samples per channel Time base range 5 ns/div to 5 s/div (in 1-2-5-range). 10 ns/div to 5 s/div 5 ns/div to 4 s/div. in a 1-2-4-sequence. Slower time/division settings using Slower time/division settings using ScopeRecord Roll mode. ScopeRecord Roll mode. Maximum record 3000 samples per channel (x2) in scope mode 10,000 samples per channel (x4) in scope length mode 27,000 points per input in ScopeRecord roll mode 30,000 points per input in (5 ms/div to 2 min/div) ScopeRecord roll mode Timing accuracy (0.01 % of reading + 1 pixel) Glitch capture 50 nsec (5 sec/div to 1 min/div) 8 ns peak detect on each channel Display and acquisition Display 144 mm full-color LCD, with backlight 153 mm full-color LCD with LED backlight Display modes Any combination of channels average on/off replay Visible screen width 12 divisions horizontally in scope mode Persistence modes Digital persistence off/short/medium/long/infinite traces fade out in seven levels Waveform mathematics A + B, A B, A * B, all with user selectable scaling of resultant One mathematical operation on 2 input A versus B (X-Y-mode) Frequency Spectrum using FFT analysis channels: add/subtract/multiply all with scalable resultant X-Y-mode Frequency Spectrum using FFT analysis Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord roll, glitch capture, waveform compare with automatic Pass/Fail testing, Replay 2 Fluke Corporation ScopeMeter 190 Series II2 Fluke Corporation ScopeMeter 190 Series II