Fluke SureGrip FTP Fused Test Probes and FTPL Fused Test Probes with Leads Technical Data Features Fluke FTP SureGrip fused test probes have build-in replaceable fuses for additional measurement protection. If the probe fuse does blow, these fused test probes will still allow the meter to indicate live voltage,* help- ing to prevent a possible misreading of no voltage present. These modu- lar probes can mount onto any standard modular test leads. Rated to CAT III 1000 V, these probes also have sheathed tips for additional safety. Built-in fuses for additional measurement protection FTP Fused Test Probes Probes allow indication of live voltage even with blown fuse* 2 mm threaded probe tips include removable 4 mm lantern-style spring contacts and removable GS38 insulated IC caps for probing closely spaced leads CAT III 1000 V, CAT IV 600 V, 10 A rating FTPL Fused Test Probe and Lead Set includes Fluke TL224 test leads Specifications Probes allow indication of live voltage even with blown fuse for added security* Built-in 1000 V, 11 A fuses with 20 kA interrupt rating 2 mm threaded probe tips include removable 4 mm lantern-style spring contacts and removable GS38 insulated IC caps for probing closely spaced leads FTPL Fused Test Probes with Leads Operating temperature -20 C to 50 C (-5 F to 120 F) CAT III 1000 V, CAT IV 600 V, 10 A rating, Pollution Degree 2 Recommended for use with Fluke modular TL224 SureGrip silicone test leads and compatible with most modular test leads Replace fuse by unscrewing probe handle at finger guard. Use only Fluke fuse part number 803293. Fluke. Keeping your world Current mode is non-functional with blown fuse up and running. FTPL Fused Test Probe and Lead Set includes Fluke TL224 test leads *Voltage readings with blown fuse are approximate and vary with the meter impedance. Fluke Corporation Before and after each measurement, verify presence of blown fuse by checking continuity of PO Box 9090, Everett, WA 98206 U.S.A. the fused test probe. See explanation below under DMM Input Impedance. Current mode is non-functional with blown fuse. Fluke Europe B.V. PO Box 1186, 5602 BD DMM input impedance Eindhoven, The Netherlands When the fuse is blown, there is a 1 Meg parallel resistor that will allow the DMM For more information call: In the U.S.A. (800) 443-5853 or to take a measurement. However, the input impedance of the DMM will have a Fax (425) 446-5116 significant effect on the reading error. As examples, see the following table: In Europe/M-East/Africa +31 (0) 40 2675 200 or DMM reading (V) if Error Fax +31 (0) 40 2675 222 Actual Voltage DMM Input Impedance FTP Fuse Blown (%) In Canada (800)-36-FLUKE or Fax (905) 890-6866 480 V 60 Hz 10 M ohms 100 pf 417.9 12.9 From other countries +1 (425) 446-5500 or 480 V 60 Hz 1 M ohms 100 pf 226.3 52.8 Fax +1 (425) 446-5116 480 V 60 Hz 3 k ohms 100 pf 1.3 99.7 Web access: