LIMITED WARRANTY & LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs and services are warranted for 90 days. This PM8907 warranty extends only to the original buyer or end- user customer of a Fluke authorized reseller, and Power Adapter/ does not apply to fuses, disposable batteries or to any product which, in Fluke s opinion, has been Battery Charger misused, altered, neglected or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been Instruction Sheet properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. SPECIFICATIONS Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or z Versions: different warranty on behalf of Fluke. Warranty support PM8907/801 Universal European line is available if product is purchased through a Fluke authorized sales outlet or Buyer has paid the plug 230V 10%. applicable international price. Fluke reserves the right PM8907/804 United Kingdom line to invoice Buyer for importation costs of plug 240V 10%. repair/replacement parts when product purchased in one country is submitted for repair in another country. PM8907/806 Japanese line plug 100V 10%. Fluke s warranty obligation is limited, at Fluke s option, PM8907/807 Australian line plug to refund of the purchase price, free of charge repair, or replacement of a defective product which is 240V 10%. returned to a Fluke authorized service center within PM8907/808 Universal switchable the warranty period. adapter 115V 10% or 230V 15% with plug EN60320-2.2G. To obtain warranty service, contact your nearest Fluke authorized service center or send the product, with a PM8907/813 North American line description of the difficulty, postage and insurance plug 120V 10%. prepaid (FOB Destination), to the nearest Fluke z Line frequency: 50, 60, and 400 Hz authorized service center. Fluke assumes no risk for damage in transit. Following warranty repair, the 10%. product will be returned to Buyer, transportation z Output voltage: 15V. prepaid (FOB Destination). If Fluke determines that the z Output current: 300 mA. failure was caused by misuse, alteration, accident or abnormal condition of operation or handling, Fluke will z Power consumption: 7W maximum. provide an estimate of repair costs and obtain z Output plug: 5-mm power jack per authorization before commencing the work. Following DIN 45232. repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for z Plus (+) voltage connected to outer the repair and return transportation charges (FOB contact of the 5-mm power jack. Shipping Point). z Operating temperature: 0 to +40 C THIS WARRANTY IS BUYER S SOLE AND (32 F to 104 F). EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Sep 1996, Rev.4 8/08 Since some countries or states do not allow limitation 1996-2008 Fluke Corporation. All rights reserved. of the term of an implied warranty, or exclusion or Printed in The Netherlands. limitation of incidental or consequential damages, the Fluke Corporation Fluke Industrial B.V. All product names are trademarks of their respective limitations and exclusions of this warranty may not P.O. Box 9090 P.O. Box 90 companies. apply to every buyer. If any provision of this Warranty Everett 7600 AB Almelo is held invalid or unenforceable by a court of WA 98206-9090 The Netherlands competent jurisdiction, such holding will not affect the USA validity or enforceability of any other provision. OPERATION Please read these instructions carefully before using the Power Adapter/Battery Charger. Warning To avoid electrical shock, connect the PM8907 Power Adapter to the AC outlet before connection to the ScopeMeter test tool. z The Power Adapter/Battery Charger Figure 1. PM8907/801 Figure 4. PM8907/807 operates the ScopeMeter test tool from the local line. z The Power Adapter/Battery Charger charges the internal Battery Pack of the test tool. z Observe the polarity 5-mm power jack the outer contact is plus (+) polarity. z Do not open the PM8907, it is not serviceable. SYMBOLS International electrical symbols used are explained below. Figure 5. PM8907/808 Figure 2. PM8907/804 See explanation on Instruction Sheet DOUBLE INSULATION (Protection Class) Conformit Europenne Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. Figure 6. PM8907/813 Figure 3. PM8907/806 Caution Before you connect the PM8907/808 to the local line, first check the preselected voltage setting on this unit. (see Figure 5.) For connection to the mains outlet, use a power cord that complies with national standards.