M C E E T R S T Y I F S I E T D N E T M O E ScopeMeter 190 Series II Technical Data ScopeMeter 190 Series II the first high-performance scopes built for harsh industrial environments Introducing the first high-performance portable oscil- loscopes with 2 or 4 independently insulated input channels, an IP51 dust- and dripwater proof rating and a CAT III 1000 V/CAT IV 600 V safety rating. Choose from 200 MHz, 100 MHz or 60 MHz bandwidth models. Now plant maintenance engineers can take a 2- or 4-channel scope into the harsh world of industrial electronics. 190 Series II a new generation of ScopeMeter The 190 Series II include these capabilities: Up to four independent floating isolated inputs, up to 1000 V High-speed sampling: Up to 2.5 GS/sec on 2 channels simultaneously Deep memory: 10,000 points per trace waveform capture (scope mode) CAT III 1000 V/CAT IV 600 V safety rated for industrial environments Up to seven hours of battery operation using BP291 Isolated USB host port for direct data storage to a USB memory device USB device port for easy PC communication Easy access battery door for quick battery swaps in the field Compact and only 2.2 kg (4.8 lb) Security slot: lock down oscilloscope with Kensington lock while unattended IP 51 rating, dust- and drip-proof Connect-and-View triggering for intelligent, automatic triggering on fast, slow and even complex signals Frequency Spectrum using FFT-analysis Automatic capture and REPLAY of 100 screens ScopeRecord Roll mode gives 30,000 points per input channel for low frequency signal analysis TrendPlot paperless recorder mode with deep memory for long-term automatic measurements 5,000 count DMM included in the 2-channel models G M A E N E A T M I S Y T O I L 9 A 0 0 U 1 QOscilloscope Modes 190-062 190-102 190-202 190-104 190-204 Vertical deflection Number of channels 2 2 2 4 4 Bandwidth 60 MHz 100 MHz 200 MHz 100 MHz 200 MHz Rise time 5.8 ns 3.5 ns 1.7 ns 3.5 ns 1.7 ns Number of scope inputs 2 input channels plus external trigger 4 input channels Channel architecture All inputs fully insulated from each other and from ground Inputs may be activated in any combination Input coupling AC or DC, with ground level indicator Input sensitivity 2 mV/div to 100 V/div, plus variable attenuation Bandwidth limiter User selectable: 20 kHz, 20 MHz or full bandwidth Normal/invert/variable On each input channel, switched separately Input voltage CAT III 1000 V/CAT IV 600 V rated, see General Specifications for further details Vertical resolution 8 bit Accuracy (2.1 % of reading + 0.04 x range/div) 5 mV/div to 100 V/div Input impedance 1 M 1 % // 14 pF 2 pF Horizontal Maximum real-time sample rate 625 MS/s for each 1.25 GS/s for each 2.5 GS/s (2ch) 1.25 GS/s for each 2.5 GS/s (2ch) (sampled simultaneously) channel channel channel 1.25 GS/s (4ch) Record length Up to 10,000 samples per channel Time base range 10 ns/div 5 ns/div 2 ns/div 5 ns/div 2 ns/div to 4 s/div to 4 s/div to 4 s/div to 4 s/div to 4 s/div Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord Roll mode (see Recorder mode) Maximum record length 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord Roll mode (see Recorder mode) Timing accuracy (0.01 % of reading + 1 pixel) Glitch capture 8 ns peak detect on each channel (using real time sampling and data compression, at any timebase setting) Display and acquisition Display 153 mm (6 in) full-color LCD with LED backlight Display modes Any combination of channels average on/off replay Visible screen width 12 divisions horizontally in scope mode Digital persistence modes off/short/medium/long/infinite and envelope mode Waveform mathematics One mathematical operation on any 2 input channels: add/subtract/multiply X-Y-mode Frequency Spectrum using FFT analysis Acquisition modes Normal, Averaged, Auto, Single Shot, ScopeRecord roll, glitch capture, waveform compare with automatic Pass/Fail testing Replay Trigger and delay Source Input A, B or External (via meter input) Input A, B, C or D Modes Automatic Connect-and-View, free run, single shot, edge, delay, dual slope, video, video line, selectable pulsewidth (channel A only), N-cycle Connect-and-View Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals Can be switched off if preferred Video triggering (on ch.A) NTSC, PAL, PAL+, SECAM Includes field 1, field 2 and line select High-res, non-interlaced video Non-interlaced video with line-select, for line frequencies in the range 14 kHz up to 65 kHz Pulse width triggering Pulse width qualified by time (on channel A) Allows for triggering <t, >t, =t, t, where t is selectable in minimum steps of 0.01 div or 50 ns Time delay 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay Dual slope triggering Triggers on both rising and falling edges alike N-cycle triggering Triggers on N-th occurrence of a trigger event N to be set in the range 2 to 99 2 Fluke Corporation ScopeMeter 190 Series II2 Fluke Corporation ScopeMeter 190 Series II