DC Current Transducer The CR5200 Series, DC Current Transducers are designed to DIN RAIL / PANEL MOUNT, RMS provide a DC signal which is proportional to a DC sensed current. These devices are designed for direct current only, targeting them towards general and daily applications. The ranges 2 to 10 Amp utilize an advanced Magnetic Modulator technology and the ranges 20 amps and above utilize Hall Effect technology. Applications Battery chargers and systems DC motor drives Power supply management Mobile applications CR5210 CR5211 CR5220 Single Element - .79 Window Features 0.1 to 600 ADC Input Range Closed loop sensing for accuracy C 35mm DIN rail or panel mount Available with 5 VDC, 10 VDC or 4 - 20 mADC outputs Non-contact DC current sensing Connection diagram printed on case Regulatory Agencies Constructed to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR5210S CR5211S CR5220S Single Element - 1.2 Window 20 to 600 ADC Input Range E199795 All single phase current transducers are available in split Contact Factory for Custom 5 VDC, 10 VDC core design. Simply put an S at the end of the prefix* or 4 - 20 mADC Output Options I.E. CR5210S-30 Add suffix for input range 2- 0-2 ADC 5 - 0-5 ADC PART NUMBERS 10 - 0-10 ADC CR5210(S) Single Element with 5 VDC output (split core design) 20 - 0-20 ADC - 30 - 0-30 ADC CR5211(S) Single Element with 10 VDC output (split core design) - 50 - 0-50 ADC CR5220(S) Single Element with 4 - 20 mADC output (split core design) - 75 - 0-75 ADC 100 - 0-100 ADC NOTE: DC Split Core Transducers Available in 20 Amps and Higher 150 - 0-150 ADC NOTE: CR5200 Series is available with 12V Power Supply. Use same application as 24V Power Supply. 300 - 0-300 ADC Example Part Number: CR5210-300-12V Ranges available up to and including 600 ADC The Professional Energy Monitoring Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 M N TI Web: Transducers DC Current Transducer DIN RAIL / PANEL MOUNT, RMS SPECIFICATIONS Basic Accuracy:........................ 1.0 % MTBF:......................... Greater than 100 K hours Linearity:................................... 10% to 100% FS Output Load:............... 4-20 mADC - 0 to 300 Thermal Drift:............................ 500 PPM/C 0-5 VDC - 2K or Greater Operating Temperature:............ 0C to +50C Relative Humidity:..... 5% to 95%, Non-Condensing Installation Category:................ CAT II Supply Current: Isolation Voltage:....................... 3500KVRMS/1mA/1Sec CR5210:.................... Typical 35mA Max 40mA Vibration Tested To:................... IEC 60068-2-6,1995 CR5210S:.................. Typical 30mA Max 35mA Pollution Degree:..................... 2 CR5220:.................... Typical 60mA Max 100mA Response Time: ..................... 250 ms CR5220S:.................. Typical 40mA Max 50mA Altitude:................................... 2000 meter max. Torque Specs.:........... 3.0 inch lbs. (0.4Nm) Insulation Voltage:................... 2500 VDC Weight:....................... 0.5 lbs. Supply Voltage:....................... 24 VDC 10% Frequency Range:.................. DC Only Cleaning:................................ Water-dampened cloth C 26.6 + 1.05 1 + 2 9 3.3 DIN RAIL 3 8 OUTPUT 73.1 .13 MOUNTING 4 7 - 2.88 Optional CLIP 6 Mounting 83.3 + - 5 3.28 SUPPLY - 20.1 41.8 .79 1.65 CR5210 5 VDC Output CR5211 10 VDC Output 76.6 3.02 + 50.7 2.00 1 +- 5.6 .22 2 9 OUTPUT TYP 3 8 4 7 + - 6 88.7 5 3.49 SUPPLY 25 - .98 CR5220 4 - 20 mADC Output 28.3 1.12 36.6 1.44 OUTLINE DRAWING CONNECTION DIAGRAM NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 M N TI Web: