FTR-K1 SERIES POWER RELAY 1 POLE - 16A 105 C, FLUX FREE TYPE FTR-K1 Series FEATURES Low profile (height: 15.7mm) High insulation Insulation distance (between coil and contacts): 10mm min. Dielectric strength: 5KV Surge strength: 10KV Low coil power (400mW) Glow wire compliant type available which satisfies GWT required for relay in IEC/EN 60335-1 Cadmium free contacts Safety standards UL, CSA, VDE approved UL, TV-5 rating approved (1 form A type) UL F class insulation wire Flux proof, RTII RoHS compliant Please see page 6 for more information PARTNUMBER INFORMATION FTR-K1 C K 012 W - H T - GW Example (a) (b) (c) (d) (e) (f ) (g) (a) Relay type FTR-K1 : FTR-K1-Series (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (c) Coil type / enclosure K : Standard type (400mW) (d) Coil rated voltage 012 : 5.....110 VDC Coil rating table at page 3 (e) Contact material / TV type W : AgSnO (1 form C) 2 T : AgSnO /TV-5 rated (1 form A, TV-5) 2 (f) Special type HT 105 C, flux free type (g) Option GW : Comply with GWEPT (IEC/EN 60695-2-11) Actual marking does not carry the type name :FT E.g.: Ordering code: FTR-K1CK012W-HT Actual marking: K1CK012W HT marking not part of type number printing , but next to coil rating print. 1FTR-K1 SERIES FTR-K1 SERIES n SPECIFICATION Item FTR-K1 AK ( ) T - HT FTR-K1 CK ( ) W - HT Contact Data Configuration 1 form A 1 form C Construction Single Material AgSnO 2 Resistance (initial) Max. 100m at 1A, 6VDC Contact rating (resistive) 16A, 250VAC / 24VDC 1 Max. carrying current * 20A Max. inrush current 78A 250VAC (only make contact) Max. switching voltage 440VAC / 300VDC Max. switching power 4,000VA / 384W 2 Min. switching load * 100mA, 5VDC 6 Life Mechanical Min. 20 x 10 operations 3 3 AC contact rating Min. 100 x 10 operations Min. 50 x 10 operations Electrical 3 3 DC contact rating Min. 100 x 10 operations Min. 30 x 10 operations 3 Lamp Load (UL TV-5) Min. 25 x 10 operations - Coil Data Rated power (20 C) 400 to 430mW Operate power (20 C) 200 to 210mW Operating temperature range -40 C to +105 C (no frost) Timing Data Operate (at nominal voltage) Max. 15ms (without bounce, no diode) Release (at nominal voltage) Max. 5ms (without bounce, no diode) Insulation Resistance (initial) Min. 1,000M at 500VDC Open contacts 1,000VAC (50/60Hz) 1min Dielectric strength Contacts to coil 5,000VAC (50/60Hz) 1min Surge strength Coil to contacts 10,000V / 1.2 x 50s standard wave Clearance 10mm Creepage 10mm EN61810-1, VDE0435 Voltage 250V Pollution degree 3 Material group III a Category C / 250V (Reference voltage) (VDE0110b) Other Misoperation1us 10 to 55 to 10Hz single amplitude 0.35mm Vibration resistance Endurance 10 to 55 to 10Hz single amplitude 0.75mm Misoperation1us 100m/s (11 1ms) Shock Endurance 1,000m/s (6 1ms) Weight Approximately 13g Sealing Flux proof, RTII * 1: Need to consider the heat from PCB when max. current is more than 10A. * 2: Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual load before production since reference values may vary according to switching frequencies, environmental conditions and expected reliability levels. 2