FTR-K1 SERIES POWER RELAY 1 POLE - 8A Polarized Latching Type JSL Series n FEATURES l Small footprint - Width: 10mm - Height : 12.5mm l High insulation - Insulation dist ance: 8 mm (between coil and cont acts) - Dielectric strength: 5,000 VAC (between coil and cont acts) - Surge strength: 10,000 V (between coil and cont acts) l Plastic materials - UL 94 flame clas s V-0 l RoHS compliant. Please see page 6 for more information n PARTNUMBER INFORMATION JSL D 12 M N - K Example (a) (b) (c) (d) (e) (f ) (a) Relay type JSL : JSL-Series (b) Coil type Nil : 1 coil D : 2 coils (c) Coil rated voltage 12 : 3.....24 VDC Coil rating table at page 3 (d) Cont act configuration Nil : 1 form C M : 1 form A (e) Cont act material N : A gSnO , Au plated 2 (f) Sealed type K : Wash tight 1 JSL SERIES FTR-K1 SERIES n SPECIFICATION Item JSL (1 coil) JSL (2 coils) Contact Data Configuration 1 form A , 1 form C Construction Single Material A gSnO + Au plated 2 Resistance (initial) Max. 100 m at 6VDC, 1A Contact rating (at resistive load) 8A , 250VAC / 24VDC Max. carr ying current 10A Max. switching volt age 400VAC / 150VDC Max. switching power 2,000VA / 192W Max. switching current 10A Min. switching load * 100 mA , 5 VDC 6 Life Mechanical Min. 5 x 10 operations 3 Electrical Min. 50 x 10 operations Coil Data Rated power (at 20 C) 220mW (24V coil, 250mW) 480mW Operating temperature range -40 C to +85 C (no frost) T iming Dat a Set / reset (at nominal coil volt age) Max. 10ms (without bounce, without diode) Exit ation time (at nominal coil volt age) Min. 20ms, max. 1,000ms Insulation Resistance (initial) Min. 1,000MOhm at 500VDC Dielectric strength Open cont acts 1,000VAC (50/60Hz) 1min Contacts to coil 5,000VAC (50/60Hz) 1min Surge strength Coil to contacts 10,000V / 1.2 x 50s st andard wave Clearance 8 mm Creepage 8 mm Other Misoperation>1us 10 to 55Hz double amplitude 2 mm Vibration resistance Endurance 10 to 55Hz double amplitude 3 mm Misoperation>1us Min. 200m/s (11 1ms) Shock Endurance Min. 1,000m/s (6 1ms) Weight Approximately 8 g * Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual load before production since reference values may var y according to switching frequencies, environment al conditions and expected reliability levels. 2