FTR-K1 SERIES
POWER RELAY
1 POLE - 8A Polarized Latching Type
JSL Series
n FEATURES
l Small footprint
- Width: 10mm
- Height : 12.5mm
l High insulation
- Insulation dist ance: 8 mm (between coil and cont acts)
- Dielectric strength: 5,000 VAC (between coil and cont acts)
- Surge strength: 10,000 V (between coil and cont acts)
l Plastic materials
- UL 94 flame clas s V-0
l RoHS compliant.
Please see page 6 for more information
n PARTNUMBER INFORMATION
JSL D 12 M N - K
[Example] (a) (b) (c) (d) (e) (f )
(a) Relay type JSL : JSL-Series
(b) Coil type Nil : 1 coil
D : 2 coils
(c) Coil rated voltage 12 : 3.....24 VDC
Coil rating table at page 3
(d) Cont act configuration Nil : 1 form C
M : 1 form A
(e) Cont act material N : A gSnO , Au plated
2
(f) Sealed type K : Wash tight
1 JSL SERIES
FTR-K1 SERIES
n SPECIFICATION
Item JSL (1 coil) JSL (2 coils)
Contact Data Configuration 1 form A , 1 form C
Construction Single
Material A gSnO + Au plated
2
Resistance (initial) Max. 100 m at 6VDC, 1A
Contact rating (at resistive load) 8A , 250VAC / 24VDC
Max. carr ying current 10A
Max. switching volt age 400VAC / 150VDC
Max. switching power 2,000VA / 192W
Max. switching current 10A
Min. switching load * 100 mA , 5 VDC
6
Life Mechanical Min. 5 x 10 operations
3
Electrical Min. 50 x 10 operations
Coil Data Rated power (at 20 C) 220mW (24V coil, 250mW) 480mW
Operating temperature range -40 C to +85 C (no frost)
T iming Dat a Set / reset (at nominal coil volt age) Max. 10ms (without bounce, without diode)
Exit ation time (at nominal coil volt age) Min. 20ms, max. 1,000ms
Insulation Resistance (initial) Min. 1,000MOhm at 500VDC
Dielectric strength Open cont acts 1,000VAC (50/60Hz) 1min
Contacts to coil 5,000VAC (50/60Hz) 1min
Surge strength Coil to contacts 10,000V / 1.2 x 50s st andard wave
Clearance 8 mm
Creepage 8 mm
Other Misoperation>1us 10 to 55Hz double amplitude 2 mm
Vibration resistance
Endurance 10 to 55Hz double amplitude 3 mm
Misoperation>1us Min. 200m/s (11 1ms)
Shock
Endurance Min. 1,000m/s (6 1ms)
Weight Approximately 8 g
* Minimum switching loads mentioned above are reference values. Please perform the confirmation test with actual load
before production since reference values may var y according to switching frequencies, environment al conditions and expected
reliability levels.
2