Datasheet
GE
EHHD010A0B HAMMERHEAD* Series; DC-DC Converter Power Modules
18-75Vdc Input; 12Vdc, 10A, 120W Output
Features
Compliant to RoHS II EU Directive 2011/65/EU (-Z versions)
Compliant to REACH Directive (EC) No 1907/2006
Flat and high efficiency curve
Industry standard, DOSA compliant footprint
58.4mm x 22.8mm x 8.9mm
(2.30 in x 0.9 in x 0.35 in)
Ultra wide input voltage range: 18-75 V
dc
Tightly regulated output
Remote sense
Output Voltage adjust: 90% to 110% of VO,nom
Constant switching frequency
Positive remote On/Off logic
Output overcurrent and overvoltage protection
Over temperature protection
Applications
Wide operating temperature range (-40C to 85C)
Distributed Power Architectures
Suitable for cold wall cooling using suitable Gap Pad applied
Wireless Networks
directly to top side of module
#
60950-1-2011 and CAN/CSA C22.2 No. 60950-1-
Enterprise Networks including Power over Ethernet (PoE) ANSI/UL
07, Second Edition + A1:2011 (MOD), dated March 19, 2011;
Industrial Equipment
and DIN EN 60950-1 (VDE 0805 Teil 1):2011-01; EN 60950-
1:2006 + A11:2009 + A1:2010, DIN EN 60950-1/A12 (VDE
0805-1/A12):2011-08; EN 60950-1/A12:2011-02, IEC 60950-
RoHS Compliant 1(ed.2);am1:2009
CE mark meets 2006/95/EC directive
Options
Meets the voltage and current requirements for ETSI 300-
132-2 and complies with and licensed for Basic insulation
Negative Remote On/Off logic (preferred)
rating per EN60950-1
Over current/Over temperature/Over voltage protections
2250 Vdc Isolation tested in compliance with IEEE 802.3 PoE
(Auto-restart) (preferred)
standards
th th
1/8 Brick Heat plate for 1/8 heatsinks
**
ISO 9001 and ISO 14001 certified manufacturing facilities
th
1/4 Brick heat plate with unthreaded inserts
Surface Mount version (-S)
Description
The EHHD010A0B [HAMMERHEAD*] Series, eighth-brick, low-height power modules are isolated dc-dc converters which provide a
single, precisely regulated output voltage over an ultra-wide input voltage range of 18-75Vdc. The EHHD010A0B provides 12Vdc
nominal output voltage rated for 10Adc output current. The module incorporates GEs vast heritage for reliability and quality, while
also using the latest in technology, and component and process standardization to achieve highly competitive cost. The open
frame module construction, available in both surface-mount and through-hole packaging, enable designers to develop cost and
space efficient solutions. The module achieves typical full load efficiency greater than 90% at V =24V and V =48V . Standard
IN dc IN dc
features include remote On/Off, remote sense, output voltage adjustment, overvoltage, overcurrent and over temperature
protection. An optional heat plate allows for external standard, eighth-brick or quarter-brick heat sink attachment to achieve
higher output current in high temperature applications.
* Trademark of General Electric Company.
#
UL is a registered trademark of Underwriters Laboratories, Inc.
CSA is a registered trademark of Canadian Standards Association.
VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
This product is intended for integration into end-user equipment . All of the required procedures of end-use equipment should be followed.
IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
** ISO is a registered trademark of the International Organization of Standards
September 23, 2015 2015 General Electric Company. All rights reserved. Page 1
Datasheet
GE
EHHD010A0B Series: DC-DC Converter Power Module
18 to 75V Input; 12V , 10A, 120W Output
dc dc
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter Device Symbol Min Max Unit
Input Voltage
Continuous All VIN -0.3 80 Vdc
Transient, operational (100 ms) All VIN,trans -0.3 100 Vdc
Operating Ambient Temperature All T -40 85 C
A
Maximum Heat Plate Operating Temperature -18H, H T -40 105 C
C
(see Thermal Considerations section)
Storage Temperature All T -55 125 C
stg
Altitude* All 4000 m
I/O Isolation voltage (100% factory Hi-Pot tested) All 2250 V
dc
* For higher altitude applications, contact your GE Sales Representative for alternative conditions of use.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter Device Symbol Min Typ Max Unit
Operating Input Voltage All V 18 24/48 75 V
IN dc
Maximum Input Current
All I 7.3 7.8 A
IN dc
(VIN= VIN, min to VIN, max, VO= VO, set, IO=IO, max)
Input No Load Current
VIN = 24Vdc, (IO = 0, module enabled) All IIN,No load 120 mA
80
VIN = 48V, (IO = 0, module enabled)
Input Stand-by Current All
I 5 11 mA
IN,stand-by
(V = 24 to 48V, module disabled)
IN
2 2
Inrush Transient All It 0.5 A s
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12H source impedance; VIN, min to VIN, max, IO= IOmax ; All 30 mAp-p
See Test configuration section)
Input Ripple Rejection (120Hz) All 60 dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to an integrated part
of sophisticated power architectures. To preserve maximum flexibility, internal fusing is not included, however, to achieve
maximum safety and system protection, always use an input line fuse. The safety agencies require a fast-acting fuse with a
maximum rating of 15 A (see Safety Considerations section). Based on the information provided in this data sheet on inrush energy
and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the fuse manufacturers data sheet
for further information.
September 23, 2015 2015 General Electric Company. All rights reserved. Page 2